2.2
Understanding Parts and Controls
1)
LCD viewing screen
2)
Power indicator (green LED)
3)
Red button – Power/Functions
4)
BNC Video Connector & Dust-Cap
5)
Yellow button – Advanced Menu
Functions
6)
‘D’ ring for lanyard
7)
Hand straps & Pads
8)
Mounting bracket
9)
Battery contacts
10)
Battery compartment (contains thermal
imager identification and warning labels)
11)
Lens window
Note
The colour and display type shown here may be
different to your model of thermal imager.
2.3
Preparing the Power Source
Charging the Supercell-Plus Rechargeable Batteries
1)
Connect the mains adaptor to the battery
charger and then connect to a mains
power outlet.
2)
Switch on mains power – RED LED will
flash denoting ‘Standby Mode’.
3)
Insert battery into the charger.
4)
GREEN LED will flash denoting ‘Charge
Conditioning Mode‘.
5)
Battery is fully charged – GREEN LED will light continuously denoting ‘Maintenance
Mode’.
Note
The Supercell-Plus batteries are fully charged before leaving the factory and can be used
immediately.
CAUTION!
To prevent fire or shock hazard, do not expose the battery charger unit and power adaptor to
rain or moisture.
© 2014, Infrared Systems Group Ltd.