13
isel
-flat bed installation GFV
1
6
2
7
3
4
5
6.3
Operating console
The operation of the GFV is performed using a movable operating console. It helps to install
the machine in an user-friendly manner.
À
À
À
À
À
Emergency-Stop
... removes power from the drive controller.
Unlatching by turning to the right.
Á
Á
Á
Á
Á
POWER
... to switch on the power electronics.
The power stage can only be switched on if
Emergency-Stop is unlatched and the cover is closed.
Â
Â
Â
Â
Â
Key-operated switch
... using the key you can select between the AUTO or
TEST operation modes.
AUTO = machining mode
TEST = debug mode
In debug mode, you can open the cover at any time.
Ã
Ã
Ã
Ã
Ã
START
... continues a stopped movement.
The machine continues exactly at the place where it was interrupted by the STOP key
if machining was not completed via software.
Ä
Ä
Ä
Ä
Ä
STOP
... stops the current program immediately and remains at the present (program)
location. The machine remains powered-up and the cover is locked.
Å
Å
Å
Å
Å
ACKNOWN switch
... in the TEST operation mode and while moving the axes, the push-button must be
activated for as long as the cover is opened.
The SK module removes power from the drive controller (power module) if the key is
released with the cover being open.
Æ
Æ
Æ
Æ
Æ
COVER push-button
... causes the deactivation of the safety locking device if pressed and allows thus the
opening of the cover provided that all corresponding conditions of the SK module are
met. The pushbutton is only operable if it lights up.