![ISE 1-0002-003/100 Product Manual Download Page 32](http://html1.mh-extra.com/html/ise/1-0002-003-100/1-0002-003-100_product-manual_2092451032.webp)
ise smart connect KNX Hue
Configuration
Order No. 1-0002-003
Product Manual Page 32 (60)
Object
Name
Direction
Data width
DP type
Flags
(CRWTU)
n f(n)
Obj
1 20*n+11
=
31
2 20*n+11
=
51
3 20*n+11
=
71
4 20*n+11
=
91
5 20*n+11
=
111
6 20*n+11
=
131
7 20*n+11
=
151
8 20*n+11
=
171
9 20*n+11
=
191
10 20*n+11
=
211
11 20*n+11
=
231
12 20*n+11
=
251
13 20*n+11
=
271
14 20*n+11
=
291
15 20*n+11
=
311
16 20*n+11
=
331
17 20*n+11
=
351
18 20*n+11
=
371
19 20*n+11
=
391
20 20*n+11
=
411
21 20*n+11
=
431
22 20*n+11
=
451
23 20*n+11
=
471
24 20*n+11
=
491
25 20*n+11
=
511
Set "blue" colour value
–
Light "n"
Write
1 byte
5.001
C-W--
Rubric:
Colour
Data type:
Percent (0 to 100%)
Function:
Sets the blue colour value of light "n".
Description:
1-byte object for specification of the blue colour value of light "n" between 0%
(0) and 100% (255).
Important note:
If the individual communication objects for R/G/B are used
for the RGB value, the entire RGB is not transferred to the light until all three
individual values have been received or 200 ms have passed so as to avoid
incorrect intermediate states.
Behaviour of a Hue Lux:
It is not possible to change just one colour (see
Chapter 1.3 Hue Lux). A distinction should be made between two cases:
> All three individual values are received within 200 ms:
The brightness value is set to the highest individual value in the same
way that the RGB colour code is set.
> Only one or two individual values are received within 200 ms:
The brightness value is increased accordingly if one of these values
is higher than the current set value.
This input is ignored if both values are lower than the current set
value.