iS5 iES10G Series User Manual Download Page 1

 

 

 

 

Intelligent 10 Port   

Managed Ethernet Switch   

iES10G(F) Series User’s Manual 

 

 

 

Version 1.5 

January 2016 

 
 

 
 
 
iS5 Communications Inc. 

#3-7490 Pacific Circle, 
Mississauga, Ontario, L5T 2A3 
Tel: + 905- 670- 0004 
Fax: + 289- 401- 5206 
Website: 

www.iS5Com.com

 

E-mail: 

[email protected]

 

 

   

Summary of Contents for iES10G Series

Page 1: ...Ethernet Switch iES10G F Series User s Manual Version 1 5 January 2016 iS5 Communications Inc 3 7490 Pacific Circle Mississauga Ontario L5T 2A3 Tel 905 670 0004 Fax 289 401 5206 Website www iS5Com co...

Page 2: ...y errors or omissions contained herein or for consequential damages in connection with the furnishing performance or use of this material The information given in this document is reviewed regularly a...

Page 3: ...ed Ethernet Switch 7 1 2 Software Features 7 1 3 Hardware Features 7 Hardware Installation 8 2 1 Installing the Switch on a DIN Rail 8 2 1 1 Mounting the iES10G F on a DIN Rail 8 2 2 Wall Mount Instal...

Page 4: ...1 4 9 Upgrade Firmware 28 5 1 5 DHCP Server 29 5 1 5 1 DHCP Server Setting 29 5 1 5 2 DHCP Server Client List 31 5 1 5 3 DHCP Server Port and IP bindings 31 5 1 6 Port Setting 31 5 1 6 1 Port Control...

Page 5: ...s Set List System Commands Set 72 6 3 Commands Set List Port Commands Set 74 6 4 Commands Set List Trunk command set 76 6 5 Commands Set List VLAN command set 77 6 6 Commands Set List Spanning Tree co...

Page 6: ...a laser system and is classified as a CLASS 1 LASER PRODUCT Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure Ca...

Page 7: ...iRing and standard STP RSTP MSTP Supports SNMPv1 v2c v3 RMON Port base 802 1Q VLAN Network Management Event notification by Email SNMP trap and Relay Output Web based Telnet Console CLI configuration...

Page 8: ...th iEC 61850 3 IEC 61800 3 variable speed drive systems IEC 61000 6 2 generic industrial iES10GF only Hardware Installation 2 1 Installing the Switch on a DIN Rail Each switch has a DIN Rail bracket o...

Page 9: ...l mounted The following steps show how to mount the switch on a panel or wall 2 2 1 Mounting the iES10G F on a Wall or Panel Option 1 Fix mounting brackets to the side of switch using the 4 screws inc...

Page 10: ...ase T X RJ45 fast Ethernet ports support auto negotiation Default Setting Speed auto Duplex auto Flow control disable Gigabit RJ45 port 10 2 x 10 100 1000Base T X ports Optional Fiber port not shown 3...

Page 11: ...ology has problem Fast blinking iRing work normally 6 Fault Amber On Fault relay Power failure or Port down fail 9 10 100Base TX Fast Ethernet ports LNK ACT Green On Port link up Blinking Data transmi...

Page 12: ...V Single Input 120 370VDC or 85 264VAC with a Single 10 48VDC backup There are also connections for the Failsafe Relay The Failsafe Relay is rated 1A 24VDC Connections to the Terminal block are listed...

Page 13: ...onents on the rear of the iES10G F are shown below 1 Screw holes 4 for wall mount kit 2 DIN Rail mount 100 240VAC rated equipment A 250VAC appropriately rated circuit breaker must be installed Equipme...

Page 14: ...iES10G F User Manual iS5 Communications Inc 14 3 5 Side Panel The components on the side of the iES10G F are shown below 1 Screw holes 4 for wall mount kit 2 1 1...

Page 15: ...ications Cable Types and Specifications Cable Type Max Length Connector 10BASE T Cat 3 4 5 100 ohm UTP 100 m 328 ft RJ45 100BASE TX Cat 5 100 ohm UTP UTP 100 m 328 ft RJ45 1000BASE TX Cat 5 Cat 5e 100...

Page 16: ...mit RD receive 3 RD receive TD transmit 4 Not used Not used 5 Not used Not used 6 RD receive TD transmit 7 Not used Not used 8 Not used Not used Note and signs represent the polarity of the wires that...

Page 17: ...ed via the console port using the RS232 DB 9 to RJ 45 cable provided Connect to the PC via the RS 232 DB9 connector and the RJ45 connector to the console port of the switch Console Cable pin assignmen...

Page 18: ...ement function supports Internet Explorer 5 0 or later It is based on Java Applets with an aim to reduce network bandwidth consumption and enhance access speed in an easy viewing screen Note By defaul...

Page 19: ...ual iS5 Communications Inc 19 3 The login screen appears 4 Key in the default username and password 5 Click Enter or OK The main interface of the Web based management appears Login screen Main Interfa...

Page 20: ...ation System Information interface System Information The system information will display the configuration of Basic Setting Switch Setting page Enable Location Alert Click PWR1 and PWR2 LED s of the...

Page 21: ...tting 5 1 4 1 Switch Setting Switch setting interface The following table describes the Switch setting interface page Label Description System Name Assign a name to the switch The maximum length is 64...

Page 22: ...e unique hardware address assigned by manufacturer default 5 1 4 2 Admin Password Change the web management login username and password for management security Admin Password interface The following t...

Page 23: ...e Apply button a popup dialog shows up to inform when the DHCP client is enabled IP Address Assign the IP address that the network is using If DHCP client function is enabled there is no need to assig...

Page 24: ...les or disables daylight saving time function When daylight saving time is enabled the daylight saving time period needs to be configured UTC Time zone Set the switch location time zone The following...

Page 25: ...MDT Mountain Daylight 6 hours 6 am MST Mountain Standard PDT Pacific Daylight 7 hours 5 am PST Pacific Standard ADT Alaskan Daylight 8 hours 4 am ALA Alaskan Standard 9 hours 3 am HAW Hawaiian Standa...

Page 26: ...overy Protocol function allows the switch to advertise its information to other nodes on the network and store the information it discovers LLDP configuration interface The following table describes t...

Page 27: ...the switch firmware automatically Firmware and or the configuration file can be stored on the TFTP server When the switch is rebooted the switch will upgrade automatically Before updating make sure th...

Page 28: ...estore Click restore to restore the configurations Backup File Name Enter the file name Backup Click backup to backup the configurations Help Show help file 5 1 4 9 Upgrade Firmware Upgrade Firmware a...

Page 29: ...s a DHCP server DHCP Server Configuration interface The following table describes the DHCP Server Configuration interface page Label Description DHCP Server Enable or Disable the DHCP Server function...

Page 30: ...example dynamic IP assign range is from 192 168 1 100 to 192 168 1 200 192 168 1 200 will be the End IP address Subnet Mask The dynamic IP assigned range subnet mask Gateway The gateway in the network...

Page 31: ...gs You can assign the specific IP address in the assigned dynamic IP range to a specific port While the device is connecting to the port it will ask for dynamic IP to be assigned The system automatica...

Page 32: ...for setting Speed Duplex You can set Auto negotiation 100 full 100 half 10 full or 10 half Flow Control Supports symmetrical and asymmetrical mode to avoid packet loss when congestion occurs Security...

Page 33: ...the current port status information Port Status interface 5 1 6 3 Rate Limit This function allows the system administrator to limit the traffic on all ports including broadcast multicast and flooded U...

Page 34: ...itted traffic Apply Click Apply to activate the configurations Help Show help file 5 1 6 4 Port Trunk Port Trunk Setting Static trunk or 802 3ad LACP can be selected to combine several physical links...

Page 35: ...number of active bundled ports on a port channel traffic patterns will reflect the rebalanced state of the port channel The following table describes the Port Trunk LACP interface page Label Descripti...

Page 36: ...g Master There should only be one Ring Master in a ring However if there are two or more switches which have Ring Master set to enable the switch with the lowest MAC address will be the actual Ring Ma...

Page 37: ...normal switches in RSTP mode Apply Click Apply to activate the configurations Help Show help file Note It is not recommended to set one switch as a Ring Master and a Coupling Ring at the same time Thi...

Page 38: ...ed to identify the root bridge The bridge with the lowest value and the highest priority is selected as the root If the value changes the switch must be restarted The value must be a multiple of 4096...

Page 39: ...le of 16 P2P Some of the rapid state transactions that are possible within RSTP are dependent upon whether the port concerned can only be connected to exactly one other bridge i e It is served by a po...

Page 40: ...ch supports port based and 802 1Q tagged based VLAN The default configuration for VLAN operation mode is 802 1Q 5 1 8 1 VLAN Setting Tagged based VLAN is an IEEE 802 1Q specification standard It allow...

Page 41: ...2 1Q interface page Label Description VLAN Operation Mode Configure VLAN Operation Mode disable Port Base 802 1Q GVRP Mode Enable Disable GVRP function Management VLAN ID Management VLAN provides the...

Page 42: ...to carry different VLAN frames to other switches Apply Click Apply to activate the configurations Help Show help file 5 1 8 2 VLAN Setting Port Based Traffic is forwarded to the member ports of the s...

Page 43: ...ate the configurations Help Show help file 5 1 9 SNMP Simple Network Management Protocol SNMP is the protocol developed to manage nodes servers workstations routers switches and hubs etc on an IP netw...

Page 44: ...ss objects with read only or read write permissions with the community default string public private SNMP V3 requires an authentication level of MD5 or DES to encrypt data to enhance data security SNM...

Page 45: ...Auth Password To remove a current user profile 1 Input SNMPv3 user name to be removed 2 Click Remove button Current SNMPv3 User Profile Show all SNMPv3 user profiles Apply Click Apply to activate the...

Page 46: ...uthentication Trap Version Trap Version supports V1 and V2c Add Add trap server profile Remove Remove trap server profile Help Show help file 5 1 10 Traffic Prioritization Traffic Prioritization inclu...

Page 47: ...by TOS TOS first the output priority is determined first by TOS and then by COS QoS policy Using the 8 4 2 1 weight fair queue scheme the output queues will follow 8 4 2 1 ratio to transmit packets f...

Page 48: ...tions Inc 48 Label Description Port base Priority Assign Port with a priority queue 4 priority queues can be assigned High Middle Low and Lowest Help Show help file Apply Click Apply to activate the c...

Page 49: ...fault priority value is considered and determined by the ingress port Help Show help file Apply Click Apply to activate the configurations TOS DSCP interface Label Description TOS DSCP TOS Type of Ser...

Page 50: ...conserves bandwidth by allowing the switch to send multicast traffic to only those interfaces that are connected to hosts that want to receive the traffic instead of flooding the traffic to all inter...

Page 51: ...c to the ports that are connected to registered end stations Multicast Filtering interface The following table describes the Multicast Filtering interface page Label Description IP Address Assign a mu...

Page 52: ...SNMP Additionally IP security can be restricted via remote management to some specific IP addresses Only these secure IP addresses can manage this switch remotely IP Security interface The following...

Page 53: ...will be discarded Port Security interface The following table describes the Port Security interface page Label Description MAC Address Input MAC Address of a specific port Port No Select switch port A...

Page 54: ...ddress to MAC Blacklist Add Add an entry to Blacklist table Delete Delete the entry Help Show help file 5 1 12 4 802 1x 802 1x Radius Server 802 1x makes the use of the physical access characteristics...

Page 55: ...estination port for accounting requests to the specified Radius Server Shared Key A key shared between this switch and authentication server NAS Identifier A string used to identify this switch Advanc...

Page 56: ...to activate the configurations Help Show help file 802 1x Port Authorized Mode Set the 802 1x authorized mode of each port 802 1x Port Authorize interface The following table describes the 802 1x Por...

Page 57: ...g the switch It can be managed by SYSLOG E MAIL and Fault Relay It also helps monitor the switch status on remote sites When events occur a warning message will be send to the appointed server E MAIL...

Page 58: ...rotocol to transmit event notification messages across networks Please refer to RFC 3164 The BSD SYSLOG Protocol System Warning SYSLOG Setting interface The following table describes the SYSLOG Settin...

Page 59: ...l Subject The Subject of the mail Authentication Username the authentication username Password the authentication password Confirm Password re enter password Recipient E mail Address The recipient s E...

Page 60: ...cription System Event System Cold Start Alert when system restarts Power Status Alert when power is up or down SNMP Authentication Failure Alert when SNMP authentication fails iRing Topology Change Al...

Page 61: ...d through a given potential transmission port MAC Address Table interface The following table describes the MAC Address Table interface page Label Description Port No Show all MAC addresses mapping to...

Page 62: ...able Aging Time Set the aging time for MAC Address table The value is between 0 and 3825 Default setting is 300 seconds Auto Flush MAC Address Table When ports Link Down Enable this function Apply Cli...

Page 63: ...aborted by this port Packet Collision The number of times a collision detected by this port Clear Clear all counters Help Show help file 5 1 14 4 Port Monitoring The Port Monitoring function supports...

Page 64: ...ck the TX or RX to be monitored TX The frames leave the switch port and proceed somewhere outside of the network RX The frames originate from outside the network and are received by the switch port wi...

Page 65: ...figuration data to the permanent flash memory Otherwise the current configuration will be lost when power off or system reset System Configuration interface The following table describes the System Co...

Page 66: ...iES10G F User Manual iS5 Communications Inc 66 5 1 17 System Reboot System Reboot interface...

Page 67: ...be used to configure the switch by the CLI CLI Management by RS 232 Serial Console 9600 8 none 1 none Use the RJ45 to DB9 F cable provided to connect the Switches RS 232 Console port to a PC s COM por...

Page 68: ...iES10G F User Manual iS5 Communications Inc 68 Step 3 Select appropriate COM port number...

Page 69: ...Set the COM port properties to the following 9600 Bits per second 8 Data bits No Parity 1 Stop bit and no Flow control Step 5 The Console login screen will appear Enter the Username and Password same...

Page 70: ...5 255 255 0 Default Gateway 192 168 10 254 User Name admin Password admin Follow the steps below to access the console via Telnet Step 1 Telnet to the IP address of the switch from the Windows Run com...

Page 71: ...gure command while in privileged EXEC mode switch con fig To exit to privileged EXEC mode enter exit or end Use this mode to configure parameters that apply to the Switch as a whole VLAN database Ente...

Page 72: ...string switch config system contact xxx show system info E Show system information switch show system info ip address Ip address Subnet mask Gateway G Configure the IP address of switch switch config...

Page 73: ...thernet 2 switch config if dhcpserver ipbinding 192 168 1 1 show dhcpserver configuration P Show configuration of DHCP server switch show dhcpserver configuration show dhcpserver clients P Show client...

Page 74: ...flowcontrol mode Symmetric Asymmetric I Use the flowcontrol configuration command on Ethernet ports to control traffic rates during congestion switch config interface fastEthernet 2 switch config if...

Page 75: ...to 102400 kbps or to 256000 kbps for Giga ports and zero means no limit switch config interface fastEthernet 2 switch config if bandwidth out 100 show bandwidth I Show interfaces bandwidth control swi...

Page 76: ...4 or a port list separate by a comma ex 2 3 6 Workport The amount of work ports this value could not be less than zero or be large than the amount of member ports switch config aggregator group 1 1 4...

Page 77: ...rt belongs to a trunk group this command can t be applied switch vlan vlan 8021q port 3 trunk link tag 2 3 6 99 or switch vlan vlan 8021q port 3 trunk link tag 3 20 vlan 8021q port PortNumber hybrid l...

Page 78: ...parameter switch config spanning tree priority 32767 spanning tree max age seconds G Use the spanning tree max age global configuration command to change the interval between messages the spanning tre...

Page 79: ...ost 20 stp path priority Port Priority I Use the spanning tree port priority interface configuration command to configure a port priority that is used when two switches tie for position as the root sw...

Page 80: ...h G Configure COS Priority switch config qos priority cos 22 middle qos priority tos Priority lowest low middle high G Configure TOS Priority switch config qos priority tos 3 high show qos P Display t...

Page 81: ...address table switch show mac address table static show mac address table filter P Show filter MAC address table switch show mac address table filter no mac address table static hwaddr MAC I Remove an...

Page 82: ...nmp show snmp server P Show specified trap server information switch show snmp server no snmp community strings Community G Remove the specified community switch config no snmp community strings publi...

Page 83: ...tem radiousip IP address G Use the 802 1x system radius IP global configuration command to change the radius server IP switch config 8021x system radiusip 192 168 1 1 8021x system serverport port ID G...

Page 84: ...ut global configuration command to set the server timeout switch config 8021x misc servertimeout 20 8021x misc maxrequest number G Use the 802 1x misc max request global configuration command to set t...

Page 85: ...e_fw 6 14 Commands Set List SYSLOG SMTP EVENT command set iES10G F Commands Level Description Example systemlog ip IP address G Set System log server IP address switch config systemlog ip 192 168 1 10...

Page 86: ...oth event smtp Link UP Link Down Both I Set port event for SMTP switch config interface fastethernet 3 switch config if event smtp both show event P Show event selection switch show event no event dev...

Page 87: ...tch config sntp ip 192 169 1 1 sntp timezone Timezone G Set timezone index use show sntp timezone command to get more information of index number switch config sntp timezone 22 show sntp P Show SNTP i...

Page 88: ...G Configure Control Port switch config ring controlport 2 Ring homingport Dual Homing Port G Configure Dual Homing Port switch config ring homingport 3 show Ring P Show the information of iRing switc...

Page 89: ...Flow Control 802 1D Spanning Tree Protocol 802 1p Class of Service 802 1Q VLAN Tagging 802 1w Rapid Spanning Tree Protocol 802 1X Authentication 802 1ad VLAN QinQ 802 1AB LLDP MAC addresses 8192 Prio...

Page 90: ...t MVR Multicast VLAN Registration support Network Redundancy iRing iBridge STP RSTP MSTP Warning Monitoring System Relay output for fault event alarming Syslog server client to record and view events...

Page 91: ...oF to 185oF NO FANS Operating Humidity 5 to 95 Non condensing Regulatory Approvals Regulatory Approvals FCC Part 15 CISPER EN55022 class A EMS EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4...

Page 92: ...larm 256 SysName 512 SysDescription 768 SysLocation 1024 SysContact 4096 4105 PortStatus Port 1 VTSS_PORTS Value 0x0000 Link down 0x0001 Link up 0x0002 Disable 0xffff NoPort 4352 4361 PortSpeed Port 1...

Reviews: