![IS5 COMMUNICATIONS iES22GF User Manual Download Page 80](http://html1.mh-extra.com/html/is5-communications/ies22gf/ies22gf_user-manual_2092166080.webp)
iES22GF User’s Manual
80
iS5 Communications Inc.
devices of each side.
Test Interval
Setting Interval time for sending keep alive messages (10-5000ms
default 10)
Note: Test interval should be the same on both sides.
Test Max Retry
Set the maximum number of lost frames to start Dual Port Recovery
mechanism (1-500 retries default 3 )
Note: Test Max Retry should be the same on both sides.
Apply
Click “
Apply
” to activate the configurations.
Recovery
time
is Test Max Retry x Test In 10ms.
Default Recovery time is 30ms<recovery time<40ms.
6.5
VLAN
6.7.5
VLAN Membership
You can view and change VLAN membership configurations for a selected switch stack in this page. Up
to 64 VLAN’s are supported. This page allows for adding and deleting VLAN’s as well as adding and
deleting port members of each VLAN.
Label
Description
Delete
Check to delete the entry. It will be deleted during the next save.
VLAN ID
The VLAN ID for the entry.
VLAN Name
Indicates the name of the VLAN. The VLAN Name is a string that is 0 to 32
characters in length. Alpha and numeric characters are valid.
Port Members
Checkmarks indicate which ports are members of the entry. Check or
uncheck as needed to modify the entry. The Status of each port can be:
: To include a port in the VLAN.
: To include a port in a forbidden port list in the VLAN.
: To remove or exclude the port from the VLAN.