![IS5 COMMUNICATIONS iES22GF User Manual Download Page 133](http://html1.mh-extra.com/html/is5-communications/ies22gf/ies22gf_user-manual_2092166133.webp)
iES22GF User’s Manual
133
iS5 Communications Inc.
Frame Type
Indicates the frame type of the ACE. These frame types are mutually exclusive.
Any
: any frame can match the ACE.
Ethernet Type:
only Ethernet type frames can match the ACE. The IEEE
802.3 descripts the value of length/types should be greater than or equal to 1536
decimal (equal to 0600 hexadecimal).
ARP
: only ARP frames can match the ACE. Notice the ARP frames will not match
the ACE with Ethernet type.
IPv4
: only IPv4 frames can match the ACE. Notice the IPv4 frames will not match
the ACE with Ethernet type.
IPv6:
Only IPv6 frames can match this ACE. Notice the IPv6 frames won't match
the ACE with Ethernet type.
Action
Specifies the action to take when a frame matches the ACE.
Permit:
takes action when the frame matches the ACE.
Deny:
drops the frame matching the ACE.
Rate Limiter
Specifies the rate limiter in number of base units. The allowed range is 1 to
16.
Disabled
means the rate limiter operation is disabled.
Port Redirect
Frames that hit the ACE are redirected to the port number specified here. The
allowed range is the same as the switch port number range. Disabled indicates that
the port redirect operation is disabled and the specific port number of 'Port
Redirect' can't be set when action is permitted.
Mirror
Specify the mirror operation of this port. Frames matching the ACE are mirrored to
the destination mirror port. The allowed values are:
Enabled:
Frames received on the port are mirrored.
Disabled:
Frames received on the port are not mirrored.
The default value is "Disabled".
Logging
Specifies the logging operation of the ACE. The allowed values are:
Enabled
: frames matching the ACE are stored in the system log.
Disabled
: frames matching the ACE are not logged.
Please note that system log memory capacity and logging rate is limited.
Shutdown
Specifies the shutdown operation of the ACE. The allowed values are:
Enabled
: if a frame matches the ACE, the ingress port will be disabled.
Disabled
: port shutdown is disabled for the ACE.
Counter
Indicates the number of times the ACE matched by a frame.