background image

www.irwinscienceeducation.com  [email protected]  Tel: 01376 340 506

www.irwinscienceeducation.com  [email protected]  Tel: 01376 340 506

TheIrwinPowerbaseS8isaheavy-dutypowersupplyoffering0-12Vacand0-12Vdc

outputsinapprox1Vsteps.Bothoutputsareselectedbyarotaryswitchandmaybe

usedsimultaneouslyuptoacombinedoutputcurrentof8A.

Thefrontpanelthreisaon/offswitch,fiveoutputsocketsforac,dcandearthanda

resetbutton.Theresetbuttonoperatesifthereisashortcircuitoroverloadonanyof

theoutputs.Shouldtheresetbuttonpopout,switchoffthesupply,rectifythefault,switch

onagainandpressthebuttonin.Pleasenotethatthebuttontakesabout5secondsto

resetandwillnotworkifpushedwithinthistime.

Please Note:

Theoffloadvoltagesarehigherthanmarkedonthedial.

Foraccurateoutputvoltagesasuitablevoltmeterormultimetershouldbeemployed.

Turnthedialtozero,connectyourloadandthendialuptherequiredvoltage.

Theunitalsoutilisesavoltagelimitlock,whichsetsthemaximumvoltageobtainable.

Tosetthelock,proceedasfollows:

•SlackenthelimitlockwiththeAllenkeysupplied

•Setthemaximumvoltagerequiredonthedial

•Rotatetheplasticdiscanti-clockwiseuntilthestudsitsagainsttheknobpointer

•Tightenthelimitlock

PAT testing

ThepowersupplyisclassifiedasClass1.

AsuitableearthbondtestpointisthevoltagelockAllenkeybolt.

Electromagnetic Compatibility

Theuseofthisapparatusoutsidetheclassroom,laboratory,studyareaorsimilarsuchplaceinvalidates

the conformity with the protection requirements of the Electromagnetic Conformity Directive

(89/336/EEC)andcouldleadtoprosecution.

IMPORTANT - ELECTRICAL SAFETY NOTICE

Connectiontomainselectricitysupply.Thisapparatusisdesignedtosafetyclass1.Before

connectingtothemainselectricitysupply,examinetheinformationontheapparatusrating

label.Ensurethatthemainssupplyissinglephasealternatingcurrent(a.c)offrequency

50Hzat230V,withneutralnominallyatearthpotential.

WARNING - THIS APPARATUS MUST BE EARTHED

YourIrwinproductshouldcomewithaplugwiththerecommendedfuserating.However

ifnotfittedconnectthewirestoanon-reversibleUK3pinplugasfollows:

Green/Yellowwiretotheterminalmarked:

E(Earth)colouredGreen/Yellow

Bluewiretoterminalmarked:

N(Neutral)orcolouredBlue

Brownwiretoterminalmarked:

L(Live)orcolouredBrown

LIVE PARTS SHOULD NEVER BE EXPOSED UNLESS THE APPARATUS HAVE BEEN SWITCHED OFF

AND ISOLATED FROM THE MAINS ELECTRICITY.

CORRESPONDENCE:

intheeventofanycorrespondenceconcerningthisapparatus,pleasecontactyoursupplyingagent

quotingtheircataloguenumberandserialnumbershowontheapparatus.Thiswillhelpusprocessyour

enquiryquickly.Anysparepartswhichmayberequiredaresuppliedontheunderstandingthatthe

replacementofthoserequiringtheexposureofliveelectricalconnectionswillbeundertakenbyan

electricallyqualifiedperson.