background image

 
 

 

 

 

 

Title 

750598 SingleHeater Cassette 

Id 

Manual EN 

Author 

 Andreas Lundevall 

Version 

15 of 20 

 

 

Date 

2014-09-29 

 

 

 

 

 

 

 

 

Spare parts list 

10

Pos 

Description 

Art.nr    Pos  Description 

Art.nr 

Gold foil 

Art.nr 

Net 

Art.nr 

Glass 

Fan 

120822    15 

Reflector P360  

102238 

193647 

193992 

Filter 

103055    16 

Reflector E360  

104074 

193647 

193992 

IR-lamp 360 mm 1 kW 

102700    17 

Reflector P500  

102154 

193838 

193993 

IR-lamp 360 mm 2 kW 

102699    18 

Reflector E500  

102539 

193838 

193993 

IR-lamp 360 mm 3 kW 

105074    19 

Reflector P790 

102155 

193646 

194477 

IR-lamp 500 mm 2 kW 

102706    20 

Reflector E790 

102696 

193646 

194477 

IR-lamp 790 mm 3 kW 

102701   

Pos  Description 

Art.nr 

 

 

Lamp holder 

109790    21 

Temp switch 

716098 

 

 

Cable assy. 5p SHE360 

716094    22 

External Fan G2E108 

121454 

 

 

10 

Cable assy. 5p SHE500 

716201    23 

External Fan G2E140 

122295 

 

 

11 

Cable assy. 5p SHE790 

716099    24 

Filter for fan 121454 

140104 

 

 

12 

Cable assy. 7p SHI360 

716095    25 

Filter for fan 122295 

140105 

 

 

13 

Cable assy. 7p SHI500 

716202     

 

 

 

 

14 

Cable assy. 7p SHI790 

716200     

 

 

 

 

  

 

 

 

9,10,11,12,13,14 

3,4,5,6,7 

 

15,16,17,18,19,20 

 

 

21 

 

 

 

Net 

 

3,4,5,6,7 

 

15,16,17,18,19,20 

 

Glass 

   

 

 

Summary of Contents for SingleHeater SH 312 Series

Page 1: ...Title 750598 SingleHeater Cassette Id Manual EN Author Andreas Lundevall Version 2 1 of 20 Date 2014 09 29 SingleHeater Instruction manual...

Page 2: ...ents 1 Application fields 3 2 Product description 4 3 Technical data 5 4 Risks 7 5 Installation instruction 8 6 Electrical diagram 10 7 Operating instructions 11 8 Maintenance 12 9 Trouble shooting 14...

Page 3: ...T unit for drying and heating Other examples of applications could be hardening shrinking melting and gelatinization The SingleHeater is compact and easy to install If a larger area is to be heated se...

Page 4: ...has an integral fan for internal cooling also available with external fan The cassette is supplied ready for electrical connection and mechanical installation There is a number of different cables typ...

Page 5: ...A SH 31 12 23 1 4 3 230 10 slow SH 322 2 8 7 230 10 slow SH 332 3 13 230 16 slow SHE 342 4 17 4 230 20 slow SH 524 2 5 400 10 slow SH 734 3 7 5 400 10 slow Only with external cooling Environment 3 2...

Page 6: ...Height B mm Depth C mm C C D mm Min Airflow Cooling m3 h SHI4 5 6 312 1 8 1 1 363 92 97 58 244 18 SH 322 36 SH 332 54 SHE 342 72 SH 524 2 1 1 4 503 36 SH 734 2 8 2 1 793 54 Height with Protection Net...

Page 7: ...nt content in the atmosphere exceeds 25 of the lower explosion limit Please refer to the EN 1010 and EN 1127 standards plus draught standard prEN 1539 At installation of cassettes a distance of at lea...

Page 8: ...for the 500 mm cassette and 690 mm for the 790 mm cassette Cassettes with external fans can be installed with a minimum gap of 10 mm between each unit In case of integrated fan a distance of at least...

Page 9: ...Id Manual EN Author Andreas Lundevall Version 2 9 of 20 Date 2014 09 29 Example of cassette positioning 5 1 Angled positioning of one or more cassettes is made in order to obtain an even heating of th...

Page 10: ...Title 750598 SingleHeater Cassette Id Manual EN Author Andreas Lundevall Version 2 10 of 20 Date 2014 09 29 Electrical diagram 6 External fan Internal Fan...

Page 11: ...ater Cassette Id Manual EN Author Andreas Lundevall Version 2 11 of 20 Date 2014 09 29 Operating instructions 7 The fan should always be on when the IR lamp is on The fan should be on 3 min after the...

Page 12: ...b will cause uneven temperature on the heated surface Also check that all cables are undamaged A damaged cable can be lethally dangerous Monthly Check the gold reflectors Damaged or very dirty gold re...

Page 13: ...paper around the lamp until the fitting is ready 1 Fix the lamp in one of the Lamp holders Make sure that the terminal strip gets as far as possible underneath the square clamp Fasten the screw Bend...

Page 14: ...ction Change lamp Check fuses Check electrical connections in wiring diagram No lamps light up or all lamps go out during operation Short circuit damaged cable Incorrect connection Temperature switch...

Page 15: ...8 193993 5 IR lamp 360 mm 3 kW 105074 19 Reflector P790 102155 193646 194477 6 IR lamp 500 mm 2 kW 102706 20 Reflector E790 102696 193646 194477 7 IR lamp 790 mm 3 kW 102701 Pos Description Art nr 8 L...

Page 16: ...ctions 11 The owner of the Single Heater must as regards the manual and present conditions at site produce understandable directions for use and at an understandable language for the users The directi...

Page 17: ...lectro magnetic Compatibility EN 12198 1 2008 Safety of Machinery Optical radiation categorization Infra red light Category 2 Compliance statement The maximum value of the system impedance Zmax is 0 0...

Page 18: ...Title 750598 SingleHeater Cassette Id Manual EN Author Andreas Lundevall Version 2 18 of 20 Date 2014 09 29...

Page 19: ...Title 750598 SingleHeater Cassette Id Manual EN Author Andreas Lundevall Version 2 19 of 20 Date 2014 09 29...

Page 20: ...r Cassette Id Manual EN Author Andreas Lundevall Version 2 20 of 20 Date 2014 09 29 Hedson Technologies AB Box 1530 SE 462 28 V NERSBORG Sweden Phone 46 0 521 28 12 30 Fax 46 0 521 28 12 31 E mail ind...

Reviews: