Connections for remote control panel to AVS-1210:
To connect a CPS-1050 or CPS-1052 remote control panel to the AVS-1210 switcher the following cable is required.
CPS-1050
AVS-1210
10 Pin HE14
to
25 Pin "D"(male)
PL 5
to
PL 4
Pin
to
Pin
1A
to
14
+12 Vdc for remote control
1B
to
15
Gnd
4B
to
25
Switch pulse
2B
to
18
D - Data 3
3A
to
19
C - Data 2
3B
to
20
B - Data 1
4A
to
21
A - Data 0
2A
to
22
E - Data 4
5A
16
Busy
5B
24
Unlatch
Where connection is from a remote control panel to both video and audio switchers the above wiring should be
used between the control panel and either the AAS-1220 or AVS-1210. The two switchers are then linked with a 25
way cable wired pin to pin.
Note that he connection must always be from PL 5 on the remote control panel to PL 4 on the switcher. Additional
control panels and switchers follow the same procedure with the first control panel having no connection to PL 4
and the last switcher having no connection to PL 5.
Under no circumstances should a connection be made from a PL 4 to a PL 4 or PL 5 to a PL 5.
Connections for linking two AVS-1210 switchers:
To connect two AVS-1210 switchers the following cable is required.
AVS-1210
AVS-1210
25 Pin "D"(male)
to
25 Pin "D"(male)
PL 5
to
PL 4
Pins 1 - 25
to
Pins 1 - 25
Wiring is pin to pin.
Pins 15 - 25 only are required unless special options are in use. For convenience a 25 way ribbon cable may be used
with all pins connected.