PCW Control
S
Installation
17
(
3
) Site Settings: Add/Remove Controller –
Manage multiple controller operation and
rain sensor input within this section of the
Settings panel. A check box is provided to
enable/disable up to four controllers per
site. Each additional controller increases
the displayed zone count in Controller 1
up to 12 zones, for a maximum a total of 48
zones.
• Rain Sensor Options
– Also included
in this panel section are the
Rain Sensor
configuration options. To utilize an auxil-
iary rain sensor with Controller 1, the
Use
Rain Sensor
box must be selected and the
rain sensor hardware must be connected to
the controller.
Note:
When the rain sensor option is selected,
all zones will be assigned to the rain sensor
control, as indicated by RS in the lower right
corner of each Zone Box (Figure 2.28)
To isolate a zone from rain sensor operation,
such as watering areas not exposed to rainfall, deselect the rain sensor option within the individual
Zone Properties menu.
In systems where multiple controllers are utilized, the rain sensor connected to Controller 1 can be
linked electronically to each additional controller by selecting the
Remote
option. If an additional
controller has a dedicated rain sensor connection, select the
Local
option for that controller.
Note:
The Rain Sensor option is selectable by zone within the Zone Properties menu, but must first be
enabled in the Site Settings panel to become available within the individual zone setup menu.
Note:
Some of the selections in the Settings panel must be
saved and uploaded to the controller site to become effec-
tive. Selecting the
Apply button followed by the
Save
and/
or
Send
button is required each time a selection is made.
(
4
) Overlap Limit –
By default, the controller is restricted to operate one zone at a time, regardless
of the watering schedule. If the irrigation supply source is capable of providing sufficient capacity
to operate more than one watering zone at a time, the
Overlap Limit
can be set to enable up to two
additional zones to operate simultaneously. “0” equals no overlap, one zone at a time.
Caution: The maximum field output is 24 VAC, 0.4A per station, with a combined total not to
exceed 1.0A (including a master valve or pump start relay and zones designated for lighting).
Exceeding this limit will activate the controller’s automatic circuit breaker to restrict field
output.
(
5
) Rain Delay –
Automatic controller operation can be manually set to prevent watering from 1 to
7 days by moving the sliding pointer to the right. Automatic operation will resume at the end of the
delay period, or can be reinstated at any time by moving the slider back to the left stop. (Not for use
with a rain sensor.)
1
2
3
4
5
Figure 2.28