34
Pellet Insert ZC Kit Assembly
(ref. form # 775277M)
Kit Contents
(refer to Figure 53)
1 ea. Back panel (A)
1 ea. Left side panel (B)
1 ea. Right side panel (C)
1 ea. Top panel (D)
1 ea. Access panel (E)
1 ea. Flue block off plate (F)
2 ea. Standoff brackets (G) - marked S
2 ea. Standoff brackets (H) - marked T
1 ea. Back Stand-off Bracket (I) - marked B
26 ea. 1/8” x 1/2” Screws (J)
4 ea. Door Washers (K)
1 ea. Rear Vent Adaptor (L)*
* The rear vent adaptor (cat. no. H5147) is only required for rear vent applications
and must be ordered separately.
Figure 54
Figure 55
3. Assemble the perimeter (see Figure 56) - Using only the bottom 2
holes on each side, screw the left side panel (B) and the right side
panel (C) to the back panel (A).
Tools Required
1/4” Nut Driver, 1/8” Drill
IMPORTANT NOTE: ALL THE STAND-OFFS PROVIDED IN THIS KIT MUST
BE INSTALLED ON THE PANELS PER THESE INSTRUCTIONS. THEY ARE
REQUIRED TO ENSURE PROPER CLEARANCES.
BEFORE INSTALLING THE APPLIANCE REVIEW ALL REQUIREMENTS IN
THIS MANUAL PROVIDED WITH THE APPLIANCE. ALL WARNINGS AND
PRECAUTIONS IN THIS MANUAL APPLY TO THESE INSTRUCTIONS.
DETERMINE THE VENT CONFIGURATION. FOLLOW INSTRUCTIONS IN
THE INSTALLATION AND OPERATION MANUAL AND VENT MANUFAC-
TURER’S INSTRUCTIONS.
DETERMINE THE FLOOR PROTECTION REQUIREMENTS. FOLLOW
INSTRUCTIONS IN THE INSTALLATION AND OPERATION MANUAL.
IF ANYTHING OTHER THAN A MASONRY HEARTH IS USED WITH THE
WINSLOW FIREPLACE INSERT, YOU MUST USE HEAT KIT, CAT. NO.
79024 - SOLD SEPARATELY. IF A MASONRY HEARTH IS USED IT MUST
EXTEND THE FULL WIDTH AND DEPTH OF THE ENCLOSURE AND TO
THE FRONT AS SPECIFIED IN THE INSTALLATION AND OPERATION
MANUAL.
Cat. No.
Model
Description
79025
PI40-ZCK
PI40GL Pellet ZC Kit
Figure 53 - Kit Contents
D
y
z
A
F
E
L
K
J
I
G
H
B
C
L
L
Flat Edge
NOTE: Top or rear vent? If you will be venting out the top then you will
install the block off plate (F in Figure 53) onto the lower back panel (A)
in the spot that is marked “z” in Figure 53. If you are venting out the
back you will install the block off plate (F) onto the top panel (D) in the
spot that is marked “y” in Figure 53. You will use four of the sheet metal
screws provided to attach the block off plate (F).
Installation Instructions
1. For a rear vent termination, remove the flue clean out box on the
PI40GL pellet insert by removing the three screws (1 on top and 1
on both the right and left side) that hold it in place. Using these same
screws, install the rear vent adaptor (L) in place of the flue clean out
box (see Figure 54).
2. When installing the rear vent adaptor (L), ensure that the flat edge is
directed towards the inside of the stove (see Figure 55).