background image

SAFETY / LISTING LABEL - MODELS C160TGL AND C160AGL

(A) Clearance from Insert top to Mantel = USA-24”, CAN-

26” (660mm). Maximum mantel depth = 9"

(B) Clearance from insert  top to combustible = USA -15” 

CAN-18” (450mm)

(C)  Minimum  clearance  to  combustible  sidewall  =  20” 

(508mm)

(D)  Minimum  clearance  to  combustible  side  trim  =  12” 

(305mm)

(E) Minimum distance of floor protection to the side = 8” 

(200mm).  This  is  measured  from  the  sides  of  the  door 

opening in the USA and from the sides of the insert in 

Canada.

 

(F) Minimum distance from front of insert to combustible 

 

= 18” (450mm).

The  hearth  and/or  floor  protection  must  be  a  thermally  rated  non-combustible  hearth/floor 

protector meeting or exceeding a thermal rating of k=.84 or equivalent with a listed thickness 

of 3/8" (9.5mm) minimum in USA (3/4" - 19mm minimum in Canada).  Install only in a masonry 

fireplace, built to UBC Chapter 37 or approved factory-built fireplace (see owner’s manual).  Do 

not remove brick or mortar from masonry fireplace to accommodate insert.  Use flue outlet with 

or without a direct connector.  Approved with minimum 6” (152mm) diameter stainless steel listed 

  .

y

l

d

i

p

a

r

u

c

c

o

 

y

a

m

 

p

u

 

d

li

u

b

 

e

t

o

s

o

e

r

c

 

s

a

 ,

y

lt

n

e

u

q

e

rf

 t

i

n

u

 

d

n

i

h

e

b

 

n

a

e

l

c

 

d

n

a

 

e

v

o

m

e

R

  

.

m

e

t

s

y

s

 

e

n

il

e

r

See owner’s manual for reductions on mantel, trim and floor protection.

* Reduced clearances may be available for A, B, C, and D dimensions by using optional mantel and/or 

side shields.  Consult with your Innovative Hearth Products dealer for the dimensions of the shields.

**  Hearth  extension  reductions:  2"  (51mm)  reduction  for  2"  (51mm)  raised  hearth.  16"  (406mm) 

minimum hearth extension on all inserts as measured from the door opening of the unit.

HOT WHILE IN OPERATION. DO NOT TOUCH.  

KEEP CHILDREN, CLOTHING, FURNISHINGS 

AND  COMBUSTIBLE  MATERIAL  A  CONSIDERABLE  DISTANCE 

AWAY.  CONTACT  MAY  CAUSE  SKIN  BURNS.  SEE  NAMEPLATE 

AND INSTRUCTIONS. DO NOT OVERFIRE. IF HEATER OR CHIMNEY 

CONNECTOR  GLOWS,  YOU  ARE  OVERFIRING.  INSPECT  AND 

CLEAN CHIMNEY AND CONNECTOR FREQUENTLY. UNDER CERTAIN 

CONDITIONS OF USE, CREOSOTE BUILDUP MAY OCCUR RAPIDLY. DO NOT USE GRATE 

OR ELEVATE FIRE - BUILD WOOD FIRE DIRECTLY ON HEARTH.   FEED DOOR MUST BE 

CLOSED DURING FIRING EXCEPT WHEN ADDING FUEL. KEEP ASH DOOR CLOSED TO 

AVOID EXCESS HEAT.  DANGER: RISK OF ELECTRICAL SHOCK. DISCONNECT POWER 

BEFORE SERVICING UNIT.   

  TYPE OF FUEL: SOLID WOOD ONLY.

CAUTION:

CONTACT YOUR LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA

COMMUNIQUEZ AVEC LES AUTORITÉS LOCALES EN BÂTIMENT OU LE SERVICE DE PRÉVENTION DES INCENDIES POUR CONNAÎTRE LES NORMES D'INSTALLATION ET D'INSPECTION DE VOTRE RÉGION

Listed Factory-built or Masonry Fireplace Accessory/Insert / Poêle encastrable certifié pour installation dans un foyer de maçonnerie ou préfabriqué

Serial No.

Numéro de série
Model / Modèle:  C160TGL
 

 

C160AGL

Tested to/Testé selon: UL 1482, ULC S628

Type Of Fuel: Solid Wood Only

Report No./Numéro de Rapport: 14-186

C160GL-

"PREVENT HOUSE FIRES"

Install  and  use  only  in  accordance  with 

manufacturer's installation instructions and 

your local building codes. Do not connect this 

unit to a chimney flue serving another appliance.
Optional Blower, Part No.s: H7907 (black),  

H7909 (nickel), H7910 (brushed nickel)

Blower Electrical Rating: 120V, 60 Hz, 1 Amp

Do not route power cord under or in front of 

appliance.

Manufactured By / Fabriqué Par:

INNOVATIVE HEARTH PRODUCTS

1502 14th Street NW

Auburn, WA 98001  USA

Date of Manufacture /  Date De Fabrication

   2019   2020    2021   JAN.   FEB.   MAR.   APR   MAY   JUN   JUL   AUG   SEP   OCT   NOV   DEC

   

 

 

JANV  FEVR  MARS  AVR  MAI  JUIN  JUIL  AOÛT  SEPT   OCT   NOV   DEC

U.S. ENVIRONMENTAL PROTECTION AGENCY

Certified to comply with 2020 cordwood standard.

Part No./ No. pièce  #900902-00  Rev. 0, 01/2019 

     DO NOT REMOVE THIS LABEL  

Made in  U.S.A.

"PREVENTION DES INCENDIES''

Installer et utiliser l'appareil en conformité 

avec les directives d'installation du fabricant 

et des autorités locales en bâtiment ou le 

service de prévention des incendies. Ne pas 

brancher cette unité à un conduit de fumée 

raccordé à un autre appareil.
Type de combustible:  Bois seulement

(A) Espace entre l'encastrable et le manteau de cheminée 

= USA-24”, CAN-26” (660mm). Profondeur maximum de la 

tablette du manteau de cheminée 9"

(B)  Espace  entre  l'encastrable  et  les  matériaux 

combustibles du haut = USA -15” CAN-18”  (450mm)

(C) Espace minimum entre l'encastrable et le mur de côté 

combustible = 20” (508mm)

(D) Espace minimum entre l'encastrable et les matériaux 

combustibles du côté = 12” (305mm)

(E) Minimum requis de matériel non combustible au plancher, 

de chaque côté de l'ouverture de l'appareil = 8” (200mm)

(F) Minimum requis de matériel non combustible à l'avant 

de l'appareil = 18” (450mm)

Installer seulement dans un foyer de maçonnerie construit selon UBC Chapitre 37 ou dans un 

foyer approuvé par le fabricant (référez-vous au manuel).  Ne pas enlever de ciment ou de briques 

pour installer l'encastrable.  L'installation de la cheminée peut s'effectuer avec ou sans connecteur 

à la sortie de l'appareil.  Approuvé pour raccordement avec un conduit de tubage certifié en acier 

inoxydable de 6” (152mm) de diamètre.  Tirer l'appareil et nettoyer l'arrière fréquemment car le 

créosote peut s'y accumuler rapidement.

*Les  dégagements  minimums  peuvent  être  réduits  pour A,  B,  C,  D  en  utilisant  un  manteau 

optionnel et / ou des protecteurs latéraux.  Contacter votre détaillant Innovative Hearth Products 

pour la dimension des protecteurs requise.

**Réduction du recouvrement de plancher : 2'' (51mm) de moins si  l'encastrable est élevé de 2'' 

(51mm).  Respecter 16'' (406mm) de recouvrement de plancher minimum à l'avant de  l'encastrable.

ATTENTION:

  L'APPAREIL  EST  CHAUD  LORS 

DE L’OPÉRATION. NE PAS Y TOUCHER. RISQUE DE BRÛLURES 

CUTANÉES. TENIR LES ENFANTS, LES MATÉRIAUX COMBUSTIBLES, 

LES VÊTEMENTS ET LES MEUBLES ELOIGNÉS DE L’APPAREIL. 

VOIR LA PLAQUE SIGNALÉTIQUE ET LES DIRECTIVES.  NE PAS 

SURCHAUFFER  L'APPAREIL.  SI  L’APPAREIL  OU  LE  TUYAU  DE 

CHEMINÉE ROUGIT, VOUS SURCHAUFFEZ. INSPECTER ET NETTOYER LA CHEMINÉE ET LE 

TUYAU CONNECTEUR FRÉQUEMMENT. SOUS CERTAINES CONDITIONS, IL SE PEUT QUE 

LE CRÉOSOTE S’ACCUMULE RAPIDEMENT. NE SURÉLEVER PAS LE FEU À L'AIDE D'UN 

CHENET. DÉPOSER LES BÛCHES DE BOIS DIRECTEMENT SUR L’ÂTRE.  LA PORTE DOIT 

ÊTRE FERMÉE PENDANT L’USAGE SAUF POUR ALIMENTER LE FEU.  GARDER LA PORTE 

''BY-PASS'' (CENDRES) FERMÉE POUR ÉVITER DE SURCHAUFFER.

DANGER: RISQUES DE DÉCHARGE ÉLECTRIQUE. DÉCONNECTER LE FIL ÉLECTRIQUE DE LA 

PRISE DE CONTACT AVANT LE SERVICE. NE PAS FAIRE PASSER LE FIL ÉLECTRIQUE SOUS 

OU EN AVANT DE L’APPAREIL.

TYPE DE COMBUSTIBLE: BOIS SEULEMENT

NE PAS ENLEVER OU RECOUVRIR CETTE ÉTIQUETTE          Fabriqué aux  U.S.A.

  ,

)r

i

o

n

7

0

9

7

H

 :

s

e

c

è

i

P

 

e

D

 .

o

N

 ,

l

e

n

n

o

it

p

O

 r

u

e

t

a

li

t

n

e

V

H7909 (plaqué nickel), H7910 (plaqué nickel, fini 

brossé)

Spécification Électrique Du Ventilateur: 120V, 60 

Hz, 1 Amp
Ne pas faire passer le fil électrique sous ou en 

avant de l'appareil

Dégagements Minimums Aux Matériaux Combustibles - En Pouces (millimètres)

Minimum Clearance to Combustible Materials - Inches (millimeters)

C

US

This wood heater needs periodic inspection and repair for proper operation.

 

Consult the owner's 

manual for further information. It is against federal regulations to operate this wood heater in a 

manner inconsistent with the operating instructions in the owner's manual.

Certification test emission value 2.1 grams/hr per 2020 cordwood standard

Cet appareil de chauffage au bois doit être inspecté et entretenu périodiquement pour fonctionner 

correctement. Voir le manuel du propriétaire pour plus d'information. L'utilisation de cet appareil 

de chauffage au bois de manière incompatible avec les instructions du manuel du propriétaire 

constitue une infraction aux régulations fédérales.

Valeur d'émission du test d'homologation 2,1 g/h selon la norme 2020

 04/2019

25

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Summary of Contents for Striker C160AGL

Page 1: ...nde Num ro de la pi ce 900900 01 This appliance must be properly installed and operated in order to prevent the possibility of a house fire Please read this entire installation and operation manual be...

Page 2: ...ts 10 Installation Procedure Masonry Chimney 10 Positive Flue Connection 11 USING THIS MANUAL Please read and carefully follow all of the instructions found in this manual Please pay special attention...

Page 3: ...IN ITS ENTIRETY AND UNDER STAND THESE RULES TO FOLLOW FOR SAFETY 13 Inspectyourchimneyatleastonceamonthduringtheburn ing season to check for soot and creosote accumulations Any accumulations over 1 8...

Page 4: ...atupthechimneythanolderappliancesandfireplaces For this reason it is important to match the fireplace insert to the chimney The chimney has two functions 1 It draws combustion air into the appliance w...

Page 5: ...adequate air for combustion The fresh air requirements of this appliance must be met within the space where it will be installed Ventilation is essential when using a Solid Fuel Burning heater In wel...

Page 6: ...E OR CHIMNEY BECOMES RED REDUCE THE AMOUNT OF AIR ENTERING THE STOVE OR INSERT IMMEDIATELY Thisapplianceisdesignedtoburndryseasonednaturalwoodonly see Page 20 for a list of prohibited fuels Failure to...

Page 7: ...The final step of the baffle board baffle blanket installation will be installing the front baffle boards The front baffle boards will be the two remaining baffle boards which are the larger two baffl...

Page 8: ...the side 8 200mm This is measured from the sides of the door opening in the USA and from the sides of the insert in Canada 2 J Maximum lintel depth without flue offset or smoke deflector This applianc...

Page 9: ...cates it is a value taken from Tables 2 and 3 Using the k formula FOLLOWING EXAMPLES ARE CALCULATED FOR USA REQUIRMENTS Using the k formula Minimum k value per Inch of Specified min thickness of alter...

Page 10: ...rackets are approximately 2 51 mm away from the fireplace front 7 Install the side surround panels and push the insert up snug against thefireplaceface Thenwiththelocationselectedremovethesurround pan...

Page 11: ...off plate i e 22 gage sheet steel in the fireplace throat using masonry screws Other acceptable methods include packing noncombustible material i e high temp fiberglass or ceramic insulation around t...

Page 12: ...long bolts with the head up through the nuts attached to the insert on the lower rear corner of each side This will allow you to level the insert when placed into the fireplace Measure from the front...

Page 13: ...E OR INSERT NOTIFY YOUR INSURANCE COMPANY CHIMNEY LINER INSTALLATION Place the insert into the fireplace making sure to center it side to side Slide the insert in until the surround mounts are approxi...

Page 14: ...while the front door is slightly open Once kindling is burning well larger pieces of wood may be added then the door should be fully closed if there was the need to keep it slightly open during start...

Page 15: ...the blower will automatically turn off Rheostat Operation The highest blower speed is obtained by turning the rheostat knob clockwise until it clicks ON then rotate towards HIGH to increase blower spe...

Page 16: ...00 degrees on Elite inserts locate thermometer on the face of the insert just above the door Now load the firebox and set the draft control At this point you may need to burn the fireplace insert with...

Page 17: ...e graphite WARNING Inspectandcleanchimneyandconnectorfrequently Under certain conditions of use creosote buildup may occur rapidly See Installing the Insert on Page 13 for instructions on removing the...

Page 18: ...tive gloves are recommended Step 5 Install New Glass Assembly Install the new glass with gasket in recess on door back use only factory supplied 5mm ceramic glass Do not substitute Step 6 Reinstall Fa...

Page 19: ...above SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OPEN and that the baffle blanket is pushed back flush with the front of the baffl...

Page 20: ...rtment for requirements in your area Carbon Monoxide Monitor Recommended Carbon Monoxide Poisoning Early signs of carbon monoxide poison ing are similar to the flu with headaches dizziness and or naus...

Page 21: ...ap Switch Gold H8076 UHPII Blower Cage Snap Switch Nickel H8077 UHPII Blower Cage Snap Switch Brushed Gold H8078 UHPII Blower Cage Snap Switch Brushed Nickel 29 H8064 Snap Switch w Gasket and Screws 3...

Page 22: ...22 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE REPLACEMENT PARTS MODELS C160TGL AND C160AGL...

Page 23: ...23 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 7 13 1 2 3 4 5 6 8 1 2 3 4 5 9 10 8 14 11 6 7 12 16 29 17 15 32 18 19 REPLACEMENT PARTS MODELS C160TGL AND C160AGL Door Parts Blower Parts...

Page 24: ...NS BLWR N SS Blower Insert Nickle H7910 WSINS BLWR BN SS Blower Insert Brushed Nickel ETCHED GLASS 71073 Glass Arch Sailboat Arch Sailboat 71069 Glass Arch Cattail Arch Cattail 71070 Glass Arch Evergr...

Page 25: ...S Installer et utiliser l appareil en conformit avec les directives d installation du fabricant et des autorit s locales en b timent ou le service de pr vention des incendies Ne pas brancher cette uni...

Page 26: ...______________________________________ ______________________________________________________ ______________________________________________________ ___________________________________________________...

Page 27: ...inder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning dry s...

Page 28: ...erial Number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions conce...