REPLACEMENT PARTS - MODELS C160TGL AND C160AGL

FRONT DOOR PARTS LIST

Item #

Cat. No

Description

1

H5639

Door Rope Kit, 7/8” Dia. (6’ 2”)

2

H5629

Upper Hinge Pin

3

H5625

Upper Hinge Pin E-Clip

4

H5628

Lower Hinge Pin

5

H5646

Lower Hinge Pin Copper Washer

6

H5640

Glass Gasket Kit (8’ 4”)

7

H5577

Set of 6 screws and 6 washers for door assembly

8

H5654

Spring Handle / Nickel

H5653

Spring Handle / Gold

9

71067

Traditional Door Glass / Plain

10

71057

Traditional Door Faceplate / Black

71058

Traditional Door Faceplate / Gold

71059

Traditional Door Faceplate / Nickel

71148

Traditional Door Faceplate / Brushed Gold

71145

Traditional Door Faceplate / Brushed Nickel

11

71072

Arch Door Glass / Plain

12

71060

Arch Door Faceplate / Black

71061

Arch Door Faceplate / Gold

71062

Arch Door Faceplate / Nickel

71147

Arch Door Faceplate / Brushed Gold

71144

Arch Door Faceplate / Brushed Nickel

13

H5579

Traditional Door Back w/ Handle

(door gasket included)

14

H5578

Arch Door Back w/ Handle (door gasket included)

USB BLOWER PARTS

Item #

Cat. No

Description

15

H8067

UHPII Wiring Harness

16

H5655

UHPI & UHPII Blower Speed Control

17

H8068

Snap Switch Bracket w/ hardware

18

H8082

Replacement Power Cord

19

H8074

UHPII Blower Cage-Snap Switch/ Black

H8075

UHPII Blower Cage-Snap Switch/ Gold

H8076

UHPII Blower Cage-Snap Switch/ Nickel

H8077

UHPII Blower Cage-Snap Switch/ Brushed Gold

H8078

UHPII Blower Cage-Snap Switch/ Brushed Nickel

29

H8064

Snap Switch w/ Gasket and Screws

32

H8066

Control Switch (Manual, Off, Automatic)

C160TGL AND C160AGL INSERT PARTS

33

71138

Small Flange Screw/ Black - Seven Needed

71128

Small Flange Screw/ Nickel - Seven Needed

34

F1871

IronStrike

®

 Nameplate Kit w/ Hardware - Nickel 

35

H5650

Draft Rod Knob

36

H5647

Tinnerman Nuts for Flange Installation - Seven 

Needed

37

H5645

Side Leveling Bolts - Two Included

38

H5644

Blower Mounting Bolts - Two Needed

39

H5612

Firebrick 4-1/2” x 9” (10 per appliance)

40

H5576

Firebrick 4-1/4” x 9” (2 per appliance)

41

H5607

Firebrick 2-1/4” x 9” (3 per appliance)

42

H3095

Firebrick 2-1/4” x 8-7/8” (1 per appliance)

43

H5604

Firebrick 1-1/2” x 9” (1 per appliance)

44

H5597

Firebrick 1-1/2” x 8-7/8” (1 per appliance)

45

H3104

Front Baffle/Secondary Burn Tube Assembly

46

H3105

Middle/Rear Baffle/Secondary Burn Tube Assembly

47

H3103

Complete Baffle/Secondary Burn Tube Assembly 

(includes tubes and all mounting hardware) 

48

H8017

Baffle Blanket 20” x 11” x 1” 

49

H8016

Baffle Board Kit w/ Baffle Blanket

MISCELLANEOUS PARTS

---

71052

Dry Graphite (Apply to door handle and door hinges)

---

H5633

Anti Seize 2 gram pouch

Contact an IHP dealer to obtain any of these parts. Never use 

substitute materials. Use of non-approved parts can result in 

poor performance and safety hazards.

Summary of Contents for Striker C160AGL

Page 1: ...nde Num ro de la pi ce 900900 01 This appliance must be properly installed and operated in order to prevent the possibility of a house fire Please read this entire installation and operation manual be...

Page 2: ...ts 10 Installation Procedure Masonry Chimney 10 Positive Flue Connection 11 USING THIS MANUAL Please read and carefully follow all of the instructions found in this manual Please pay special attention...

Page 3: ...IN ITS ENTIRETY AND UNDER STAND THESE RULES TO FOLLOW FOR SAFETY 13 Inspectyourchimneyatleastonceamonthduringtheburn ing season to check for soot and creosote accumulations Any accumulations over 1 8...

Page 4: ...atupthechimneythanolderappliancesandfireplaces For this reason it is important to match the fireplace insert to the chimney The chimney has two functions 1 It draws combustion air into the appliance w...

Page 5: ...adequate air for combustion The fresh air requirements of this appliance must be met within the space where it will be installed Ventilation is essential when using a Solid Fuel Burning heater In wel...

Page 6: ...E OR CHIMNEY BECOMES RED REDUCE THE AMOUNT OF AIR ENTERING THE STOVE OR INSERT IMMEDIATELY Thisapplianceisdesignedtoburndryseasonednaturalwoodonly see Page 20 for a list of prohibited fuels Failure to...

Page 7: ...The final step of the baffle board baffle blanket installation will be installing the front baffle boards The front baffle boards will be the two remaining baffle boards which are the larger two baffl...

Page 8: ...the side 8 200mm This is measured from the sides of the door opening in the USA and from the sides of the insert in Canada 2 J Maximum lintel depth without flue offset or smoke deflector This applianc...

Page 9: ...cates it is a value taken from Tables 2 and 3 Using the k formula FOLLOWING EXAMPLES ARE CALCULATED FOR USA REQUIRMENTS Using the k formula Minimum k value per Inch of Specified min thickness of alter...

Page 10: ...rackets are approximately 2 51 mm away from the fireplace front 7 Install the side surround panels and push the insert up snug against thefireplaceface Thenwiththelocationselectedremovethesurround pan...

Page 11: ...off plate i e 22 gage sheet steel in the fireplace throat using masonry screws Other acceptable methods include packing noncombustible material i e high temp fiberglass or ceramic insulation around t...

Page 12: ...long bolts with the head up through the nuts attached to the insert on the lower rear corner of each side This will allow you to level the insert when placed into the fireplace Measure from the front...

Page 13: ...E OR INSERT NOTIFY YOUR INSURANCE COMPANY CHIMNEY LINER INSTALLATION Place the insert into the fireplace making sure to center it side to side Slide the insert in until the surround mounts are approxi...

Page 14: ...while the front door is slightly open Once kindling is burning well larger pieces of wood may be added then the door should be fully closed if there was the need to keep it slightly open during start...

Page 15: ...the blower will automatically turn off Rheostat Operation The highest blower speed is obtained by turning the rheostat knob clockwise until it clicks ON then rotate towards HIGH to increase blower spe...

Page 16: ...00 degrees on Elite inserts locate thermometer on the face of the insert just above the door Now load the firebox and set the draft control At this point you may need to burn the fireplace insert with...

Page 17: ...e graphite WARNING Inspectandcleanchimneyandconnectorfrequently Under certain conditions of use creosote buildup may occur rapidly See Installing the Insert on Page 13 for instructions on removing the...

Page 18: ...tive gloves are recommended Step 5 Install New Glass Assembly Install the new glass with gasket in recess on door back use only factory supplied 5mm ceramic glass Do not substitute Step 6 Reinstall Fa...

Page 19: ...above SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OPEN and that the baffle blanket is pushed back flush with the front of the baffl...

Page 20: ...rtment for requirements in your area Carbon Monoxide Monitor Recommended Carbon Monoxide Poisoning Early signs of carbon monoxide poison ing are similar to the flu with headaches dizziness and or naus...

Page 21: ...ap Switch Gold H8076 UHPII Blower Cage Snap Switch Nickel H8077 UHPII Blower Cage Snap Switch Brushed Gold H8078 UHPII Blower Cage Snap Switch Brushed Nickel 29 H8064 Snap Switch w Gasket and Screws 3...

Page 22: ...22 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE REPLACEMENT PARTS MODELS C160TGL AND C160AGL...

Page 23: ...23 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 7 13 1 2 3 4 5 6 8 1 2 3 4 5 9 10 8 14 11 6 7 12 16 29 17 15 32 18 19 REPLACEMENT PARTS MODELS C160TGL AND C160AGL Door Parts Blower Parts...

Page 24: ...NS BLWR N SS Blower Insert Nickle H7910 WSINS BLWR BN SS Blower Insert Brushed Nickel ETCHED GLASS 71073 Glass Arch Sailboat Arch Sailboat 71069 Glass Arch Cattail Arch Cattail 71070 Glass Arch Evergr...

Page 25: ...S Installer et utiliser l appareil en conformit avec les directives d installation du fabricant et des autorit s locales en b timent ou le service de pr vention des incendies Ne pas brancher cette uni...

Page 26: ...______________________________________ ______________________________________________________ ______________________________________________________ ___________________________________________________...

Page 27: ...inder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning dry s...

Page 28: ...erial Number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions conce...