IronStrike Striker C160AGL Installation And Operation Manual Download Page 3

3

1.   When this room heater is not properly installed, a house 

fire may result. To reduce the risk of fire, follow the instal-

lation instructions. Contact local building or fire officials 

about restrictions and installation inspection requirements 

in your area. 

2.   Wear gloves during installation to avoid injury from sharp 

edges on the insert and/or its parts.

3.   This unit is designed and engineered to burn only dry, well-

seasoned wood. Burning wet wood will greatly reduce your 

inserts efficiency, produce excessive amounts of smoke 

and can cause dangerous chimney fires due to creosote 

build-up.

4.   Before opening the door, the draft control must be fully open 

to avoid possible combustion flash (ignition of hot volatile 

gases as the door is opened).

5.   Never use gasoline, gasoline-type lantern fuel, kerosene, 

charcoal lighter fluid, or similar liquids to start or ’freshenup’ 

a fire in this heater. Keep all such liquids well away from 

the heater while it is in use. DO NOT USE CHEMICALS OR 

FLUIDS TO START THE FIRE.

6.   While burning, fuel utilizes oxygen from the air in the room. 

Be sure to allow an adequate amount of fresh air into the 

room where the insert is burning.

7.   The outside surface of the insert will be hot while burning 

properly and can set items like clothing and curtains on fire. 

Keep furnishings and other combustible materials away 

from the insert. Using the heat from the insert to dry wet 

clothing can be hazardous if clothes are placed too near 

the surface of the insert.

8.   HOT WHILE IN OPERATION.  KEEP CHILDREN, CLOTHING 

FURNISHINGS AND COMBUSTIBLE MATERIAL A CONSIDER-

ABLE DISTANCE AWAY.  CONTACT MAY CAUSE SKIN BURNS. 

Do not allow children to play near the insert without close 

supervision. Do not touch the insert while it is burning. 

Use extreme caution while the unit is in use. Surface tem-

peratures become dangerously hot and can cause serious 

burns.

9.   Do not allow anyone to operate the insert who is not familiar 

with the operating instructions.

10.  Attempts to achieve heat output rates that exceed insert 

design specifications can result in permanent damage to 

the insert. Never leave your insert unattended on high burn 

rates. This may cause overfiring. Overfiring the insert may 

cause a house fire. If the insert glows, you are overfiring.

11.  Keep a water hose or hand-operated fire extinguisher close 

for safety.

12.  Smoke Detectors - Since there are always several poten-

tial sources of fire in any home, we recommend installing 

smoke detectors. If possible, install the smoke detector in 

a hallway adjacent to the room (to reduce the possibility 

of occasional false activation from the heat produced by 

the insert).  If your local code requires a smoke detector 

be installed within the same room, you must follow the 

requirements of your local code. Check with your local 

building department for requirements in your area.

IMPORTANT SAFETY AND WARNING 

INFORMATION

READ THIS MANUAL IN ITS ENTIRETY AND UNDER-

STAND THESE RULES TO FOLLOW FOR SAFETY.

13.  Inspect your chimney at least once a month during the burn-

ing season to check for soot and creosote accumulations. 

Any accumulations over 1/8” thick should be removed by 

a professional chimney sweep. Do not attempt to burn out 

heavy creosote accumulations with a hot fire. If large ac-

cumulations are occurring, review your burning procedures.

14.  If a creosote fire should develop, the fire department should 

be called immediately and then attempts should be made 

to control the fire until assistance arrives. If a “runaway” 

fire should develop causing over-heating of the insert, the 

door and draft regulators should be closed immediately. 

The fire should die down once deprived of oxygen. After a 

severe chimney fire, the complete chimney system should 

be checked before further use.

15.  Do Not Use Grate Or Elevate Fire - Build Wood Fire Directly 

On Hearth (firebrick). Do not use andirons or other methods 

of supporting the fuel. 

16. Please read this entire manual before you install and use 

your new room heater. Failure to follow instructions may 

result in property damage, bodily injury, or even death.

17.  Check all local building and safety codes before installation. 

The installation instructions and appropriate code require-

ments must be followed exactly and without compromise. 

In the absence of local codes the following standards and 

codes must be followed.

18.  In the U.S.A, install in accordance with the National Fire 

Protection Association’s Code, NFPA 211, Standards for 

Chimneys, Fireplaces, Vents and Solid-Fuel-Burning Appli-

ances, or similar regulations, may apply to the installation 

of a Solid-Fuel-Burning appliance in your area. In Canada, 

the guideline is established by the CSA Standard, CAN/

CSA-B365-M93, Installation Code for Solid-Fuel-Burning 

Appliances and Equipment.

19. 

DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY 

AIR DISTRIBUTION DUCTWORK UNLESS SPECIFICALLY 

APPROVED FOR SUCH INSTALLATIONS.

20. WARNING: BURNING IMPROPER FUEL (I.E. CHARCOAL) 

CAN RESULT IN CARBON MONOXIDE POISONING, WHICH 

MAY LEAD TO DEATH!  

21.  Carbon Monoxide Poisoning – early signs of carbon monox-

ide poisoning resemble the flu with headaches, dizziness, 

or nausea.  If you have these signs, get fresh air at once!  

Have the heater inspected by a qualified service technician.  

Some people are more affected by carbon monoxide than 

others.  These include pregnant women, people with heart 

or lung disease or anemia, those under the influence of 

alcohol, and those at high altitudes.

22.  Failure to use manufacturer provided parts, variations in 

techniques and construction materials or practices other 

than those described in this manual may create a fire hazard 

and void the limited warranty.

23.  Do not make any make-shift compromises during installa-

tion. Any modification or alteration may result in damage 

to the appliance or dwelling and will void the warranty, 

certification and listings of this unit.

24.  These appliances are designed as supplemental heaters. 

Therefore, it is advisable to have an alternate heat source 

when installed in a dwelling.

Summary of Contents for Striker C160AGL

Page 1: ...nde Num ro de la pi ce 900900 01 This appliance must be properly installed and operated in order to prevent the possibility of a house fire Please read this entire installation and operation manual be...

Page 2: ...ts 10 Installation Procedure Masonry Chimney 10 Positive Flue Connection 11 USING THIS MANUAL Please read and carefully follow all of the instructions found in this manual Please pay special attention...

Page 3: ...IN ITS ENTIRETY AND UNDER STAND THESE RULES TO FOLLOW FOR SAFETY 13 Inspectyourchimneyatleastonceamonthduringtheburn ing season to check for soot and creosote accumulations Any accumulations over 1 8...

Page 4: ...atupthechimneythanolderappliancesandfireplaces For this reason it is important to match the fireplace insert to the chimney The chimney has two functions 1 It draws combustion air into the appliance w...

Page 5: ...adequate air for combustion The fresh air requirements of this appliance must be met within the space where it will be installed Ventilation is essential when using a Solid Fuel Burning heater In wel...

Page 6: ...E OR CHIMNEY BECOMES RED REDUCE THE AMOUNT OF AIR ENTERING THE STOVE OR INSERT IMMEDIATELY Thisapplianceisdesignedtoburndryseasonednaturalwoodonly see Page 20 for a list of prohibited fuels Failure to...

Page 7: ...The final step of the baffle board baffle blanket installation will be installing the front baffle boards The front baffle boards will be the two remaining baffle boards which are the larger two baffl...

Page 8: ...the side 8 200mm This is measured from the sides of the door opening in the USA and from the sides of the insert in Canada 2 J Maximum lintel depth without flue offset or smoke deflector This applianc...

Page 9: ...cates it is a value taken from Tables 2 and 3 Using the k formula FOLLOWING EXAMPLES ARE CALCULATED FOR USA REQUIRMENTS Using the k formula Minimum k value per Inch of Specified min thickness of alter...

Page 10: ...rackets are approximately 2 51 mm away from the fireplace front 7 Install the side surround panels and push the insert up snug against thefireplaceface Thenwiththelocationselectedremovethesurround pan...

Page 11: ...off plate i e 22 gage sheet steel in the fireplace throat using masonry screws Other acceptable methods include packing noncombustible material i e high temp fiberglass or ceramic insulation around t...

Page 12: ...long bolts with the head up through the nuts attached to the insert on the lower rear corner of each side This will allow you to level the insert when placed into the fireplace Measure from the front...

Page 13: ...E OR INSERT NOTIFY YOUR INSURANCE COMPANY CHIMNEY LINER INSTALLATION Place the insert into the fireplace making sure to center it side to side Slide the insert in until the surround mounts are approxi...

Page 14: ...while the front door is slightly open Once kindling is burning well larger pieces of wood may be added then the door should be fully closed if there was the need to keep it slightly open during start...

Page 15: ...the blower will automatically turn off Rheostat Operation The highest blower speed is obtained by turning the rheostat knob clockwise until it clicks ON then rotate towards HIGH to increase blower spe...

Page 16: ...00 degrees on Elite inserts locate thermometer on the face of the insert just above the door Now load the firebox and set the draft control At this point you may need to burn the fireplace insert with...

Page 17: ...e graphite WARNING Inspectandcleanchimneyandconnectorfrequently Under certain conditions of use creosote buildup may occur rapidly See Installing the Insert on Page 13 for instructions on removing the...

Page 18: ...tive gloves are recommended Step 5 Install New Glass Assembly Install the new glass with gasket in recess on door back use only factory supplied 5mm ceramic glass Do not substitute Step 6 Reinstall Fa...

Page 19: ...above SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OPEN and that the baffle blanket is pushed back flush with the front of the baffl...

Page 20: ...rtment for requirements in your area Carbon Monoxide Monitor Recommended Carbon Monoxide Poisoning Early signs of carbon monoxide poison ing are similar to the flu with headaches dizziness and or naus...

Page 21: ...ap Switch Gold H8076 UHPII Blower Cage Snap Switch Nickel H8077 UHPII Blower Cage Snap Switch Brushed Gold H8078 UHPII Blower Cage Snap Switch Brushed Nickel 29 H8064 Snap Switch w Gasket and Screws 3...

Page 22: ...22 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE REPLACEMENT PARTS MODELS C160TGL AND C160AGL...

Page 23: ...23 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 7 13 1 2 3 4 5 6 8 1 2 3 4 5 9 10 8 14 11 6 7 12 16 29 17 15 32 18 19 REPLACEMENT PARTS MODELS C160TGL AND C160AGL Door Parts Blower Parts...

Page 24: ...NS BLWR N SS Blower Insert Nickle H7910 WSINS BLWR BN SS Blower Insert Brushed Nickel ETCHED GLASS 71073 Glass Arch Sailboat Arch Sailboat 71069 Glass Arch Cattail Arch Cattail 71070 Glass Arch Evergr...

Page 25: ...S Installer et utiliser l appareil en conformit avec les directives d installation du fabricant et des autorit s locales en b timent ou le service de pr vention des incendies Ne pas brancher cette uni...

Page 26: ...______________________________________ ______________________________________________________ ______________________________________________________ ___________________________________________________...

Page 27: ...inder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning dry s...

Page 28: ...erial Number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions conce...

Reviews: