background image

17

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

MAINTENANCE

THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR 

PROPER OPERATION. IT IS AGAINST FEDERAL REGULATIONS TO 

OPERATE THIS WOOD HEATER IN A MANNER INCONSISTENT WITH 

OPERATING INSTRUCTIONS IN THIS MANUAL.

DOOR HINGES: 

 If door hinges need lubricating, use an anti-seize com-

pound (never use oil) available from your IHP dealer.

DOOR LATCH: 

 If your door latch fails to latch tightly and the gasket is in 

good condition, place a length of pipe (cheater bar) over the inside portion 

of the door handle and bend slightly toward the door until the proper
adjustment is obtained. If the door handle does not close easily, apply 

high temperature anti-seize to the striker.

DOOR GASKET: 

 Periodically check gasket to make sure it is not over-

compressed. If compressed, replace with a special woven door rope. 

(Don’t try substituting rope, only use special IHP door rope).

PLATED ACCESSORIES: 

 Clean only with a household type glass cleaner 

and a very soft cotton cloth  Other products may damage plated finish, 

paint and gaskets.

BAFFLE BLANKETS: 

 Your baffle blankets should be inspected during 

every chimney cleaning. If the blanket is compressed or heavily stained, 

it should be replaced. Heavy creosote stains or matting is an indication 

of improper use and your burning habits should be reviewed.

GLASS CLEANING:

  Only clean glass with products specifically made to 

use on wood stoves and fireplace inserts. Other products could damage 

gaskets and paint. Never scrape glass with a razor blade. This can pit 

the glass and make it impossible to clean in the future.

WINDOW GASKET:

  The window gasket can be checked by running the 

flame of the match near the gasket and around the door. If the flame is 

drawn in around the window, the gasket should be replaced.

DOOR HANDLE: 

 Door handle may become tight as you use the fireplace 

insert. Free the handle up by using dry graphite supplied with the fireplace 

insert. The directions are included with the graphite.

       CAUTION 

Cleaning Glass: Ensure appliance is cold prior 

to cleaning glass.  A commercial glass cleaner 

designed for stoves is recommended.  Do not use 

abrasive cleaners. Do not clean with any materials, 

which may scratch or otherwise damage the glass.  

Scratches on the glass can develop into cracks or 

break.  Inspect the glass regularly.  If you detect a 

crack, extinguish the fire and contact your dealer 

for a replacement.

GLASS CLEANING GUIDELINES
WARNING: DO NOT CLEAN GLASS WHEN APPLIANCE IS HOT!

Glass on any wood stove or fireplace insert will not stay perfectly clean. 

Here are some guidelines for cleaning and caring for the glass:

•   Ensure the appliance is cold prior to cleaning glass.

•   This appliance is designed to provide a flow of air over the inside of 

the glass, where along with high heat helps inhibit build-up on the 

glass.  When build-up occurs, a commercial glass cleaner designed 

for stoves is recommended.  Regular household glass cleaners will 

not clean creosote.

•   Do not use abrasives such as steel pads, steel wool or oven cleaner 

as they will scratch the glass. Never scrape glass with a razor blade 

as this may pit the glass and make it impossible to clean in the future.

•   Do not use chemical glass cleaners as they may damage the gaskets 

or painted surfaces.

TIPS FOR KEEPING THE GLASS CLEAN

•   Burn only dry seasoned cord wood.  Wet wood = Dirty glass.

•   A short, hot fire (15 - 20 minutes) may help to clean off some of the 

normal buildup. Lower burns = more build-up. Higher burns = less 

build-up.

•   Keep freshly loaded wood away from the glass.

•   After reloading, allow all the wood to catch flame before dampering 

down the appliance. 

       WARNING 

Inspect and clean chimney and connector frequently. 

Under certain conditions of use, creosote buildup 

may occur rapidly. See 

Installing the Insert

 on 

Page 

13

 for instructions on removing the appliance for 

cleaning (reverse order of instructions).

Have your product inspected at least once a year by a qualified 

service technician to ensure gaskets, air tubes, baffles, and venting 

are in good repair to ensure proper performance. Have degraded 

items replaced by a qualified service technician.

Summary of Contents for Performer C210

Page 1: ...ro de la pi ce 900102 00 This appliance must be properly installed and operated in order to prevent the possibility of a house fire Please read this entire installation and operation manual before ins...

Page 2: ...Chimney Requirements 10 Installation Procedures Masonry Chimney 10 Positive Flue Connection 11 Installation Procedure Factory Built Zero Clearance Fireplaces 11 Fireplace Pre Installation Preparation...

Page 3: ...by a professionalchimneysweep Donotattempttoburnoutheavy creosoteaccumulationswithahotfire Iflargeaccumulations are occurring review your burning procedures 14 If a creosote fire should develop the fi...

Page 4: ...ccessories may turn color stove glass may develop a haze which will not come off with cleaning Overfiring of a stove or fireplace insert is a condition where excessive temperatures are reached beyond...

Page 5: ...tion is essential when using a Solid Fuel Burning heater In well insulated and weather tight homes it may be difficult to establish a good draft up the chimney caused by a shortage of air in the home...

Page 6: ...f three burns The first two should last for 20 minutes each at 250 degrees the appliance should be allowed to cool completely between each burn The third should be a burn of at least 450 degrees F for...

Page 7: ...nstall the two remaining boards where you originally installed the first two boards on each side of the baffle support and pushed against the rear of the unit The stainless steel support hanger should...

Page 8: ...from the door opening of the unit Canada 18 450 mm minimum hearth extension on all stoves and inserts as measured from the door opening of the unit Minimum distance of floor protection to the side 8...

Page 9: ...asterisk indicates it is a value taken from Tables 2 and 3 FOLLOWING EXAMPLES ARE CALCULATED FOR USA REQUIRMENTS Using the k formula Minimum k value per Inch of Specified min thickness of alternate ma...

Page 10: ...nter of the fireplace opening and push it back until the surround brackets are approximately 2 51 mm away from the fireplace front 7 Install the side surround panels and push the insert up snug agains...

Page 11: ...pproved methods of achieving a positive flue connection See Figure 9 A qualified installer should evaluate the existing fireplace to determine the best method for achieving a positive flue connection...

Page 12: ...Factory Built Zero Clearance Fireplaces Fireplace Pre Installation Preparation NOTE IHP RECOMMENDS PROFESSIONAL INSTALLATION BY A LICENSED AND BONDED INSTALLER SEE YOUR DEALER FOR RECOMMENDATIONS IMP...

Page 13: ...Part H5296 is available to fill the space between the insert and the hearth protection Install the brick and baffle as per Page 7 Chimney Liner Installation Installing the Insert Post Installation Ch...

Page 14: ...ermometer can be a helpful tool to help ensure you are not over firing your appliance and it will also ensure you are burning fuel at a rate that is most efficient Place a stove thermometer on the top...

Page 15: ...turn off continue to rotate the knob counterclockwise until it clicks OFF Blower Speed Control Knob rheostat Manual Auto Rocker Switch Blower Operation Guidelines While in auto operation mode the blo...

Page 16: ...locate thermometer on the face of the insert just above the door Now load the firebox and set the draft control At this point you may need to burn the fireplace insert with the draft open for a few m...

Page 17: ...are included with the graphite CAUTION Cleaning Glass Ensure appliance is cold prior to cleaning glass A commercial glass cleaner designed for stoves is recommended Do not use abrasivecleaners Donotc...

Page 18: ...rotective gloves are recommended Step 5 Install New Glass Assembly Install the new glass with gasket in recess on door back use only factory supplied 5mm ceramic glass Do not substitute Step 6 Reinsta...

Page 19: ...ss above SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OPEN and that the baffle blankets are pushed back flush with the front of the...

Page 20: ...requirements in your area Carbon Monoxide Monitor Recommended Carbon Monoxide Poisoning Early signs of carbon monoxide poison ing are similar to the flu with headaches dizziness and or nausea If you...

Page 21: ...dware 18 H8082 Replacement Power Cord 19 H8074 UHPII Blower Cage Snap Switch Black H8075 UHPII Blower Cage Snap Switch Gold H8076 UHPII Blower Cage Snap Switch Nickel H8077 UHPII Blower Cage Snap Swit...

Page 22: ...22 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 33 34 36 36 45 46 47 37 37 35 40 44 40 38 38 38 41 38 38 38 41 38 38 42 38 38 38 38 42 38 38 39 39 43 39 39 Replacement Parts Model C210 and CA210...

Page 23: ...23 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 7 13 1 2 3 4 5 6 8 1 2 3 4 5 9 10 8 14 11 6 7 12 16 29 17 15 32 18 19 Replacement Parts Model C210 and CA210 Door Parts Blower Parts...

Page 24: ...N 71021 WFT2640 B Black 26 3 4 x 40 71022 WFT2648 B Black 26 3 4 x 48 71025 WFT3040 B Black 30 3 4 x 40 71026 WFT3048 B Black 30 3 4 x 48 71007 WFT2640 G Gold 26 3 4 x 40 71008 WFT2648 G Gold 26 3 4 x...

Page 25: ...a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning d...

Page 26: ...a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices a...

Reviews: