background image

21

FRONT DOOR PARTS LIST

Item #

Cat. No.

Description

1

H5639

Door Rope Kit, 7/8” Dia. (6’ 2”)

2

H5629

Upper Hinge Pin

3

H5625

Upper Hinge Pin E-Clip

4

H5628

Lower Hinge Pin

5

H5646

Lower Hinge Pin Copper Washer

6

H5640

Glass Gasket Kit (8’ 4”)

7

H5577

Set of 6 screws and 6 washers for door assembly

8

H5654

Spring Handle / Nickel

H5653

Spring Handle / Gold

9

71067

Traditional Door Glass / Plain

71068

Traditional Door Glass / Sailboat

71063

Traditional Door Glass / Cattail

71065

Traditional Door Glass / Evergreen

71066

Traditional Door Glass / Floral

10

71057

Traditional Door Faceplate / Black

71058

Traditional Door Faceplate / Gold

71059

Traditional Door Faceplate / Nickel

71148

Traditional Door Faceplate / Brushed Gold

71145

Traditional Door Faceplate / Brushed Nickel

11

71072

Arch Door Glass / Plain

71073

Arch Door Glass / Sailboat

71069

Arch Door Glass / Cattail

71070

Arch Door Glass / Evergreen

71071

Arch Door Glass / Floral

12

71060

Arch Door Faceplate / Black

71061

Arch Door Faceplate / Gold

71062

Arch Door Faceplate / Nickel

71147

Arch Door Faceplate / Brushed Gold

71144

Arch Door Faceplate / Brushed Nickel

13

H5579

Traditional Door Back w/ Handle (door gasket 

included)

14

H5578

Arch Door Back w/ Handle (door gasket included)

USB BLOWER PARTS

15

H8067

UHPII Wiring Harness

16

H5655

UHPI & UHPII Blower Speed Control

17

H8068

Snap Switch Bracket w/ hardware

18

H8082

Replacement Power Cord

19

H8074

UHPII Blower Cage-Snap Switch/ Black 

H8075

UHPII Blower Cage-Snap Switch/ Gold 

H8076

UHPII Blower Cage-Snap Switch/ Nickel 

H8077

UHPII Blower Cage-Snap Switch/ Brushed Gold 

H8078

UHPII Blower Cage-Snap Switch/ Brushed Nickel 

29

H8064

Snap Switch w/ Gasket and Hardware

32

H8066

Control Switch (Manual, Off, Automatic)

C/A210 INSERT PARTS

33

71139

Large Flange Screw/ Black - Seven Needed

H5294

Large Flange Screw/ Gold - Seven Needed

H5295

Large Flange Screw/ Nickel - Seven Needed

34

F1871

IronStrike™ Nameplate Kit w/ Hardware - Nickel 

F1872

IronStrike Nameplate Kit w/ Hardware - Gold

35

H5650

Draft Rod Knob

36

H5645

Side Leveling Bolts - Two Included

37

H5644

Blower Mounting Bolts - Two Needed

38

H5612

Firebrick 4-1/2” x 9” (14 per stove)

39

H5606

Firebrick 4-1/2” x 5-1/2” (4 per stove)

40

H5605

Firebrick 3” x 9” (2 per stove)

41

H5611

Firebrick 2-1/8” x 9” (2 per stove)

42

H5599

Firebrick 1-1/2” x 9” (2 per stove)

43

H3096

Firebrick 1-1/2” x 5-1/2” (1 per stove)

44

H5603

Firebrick 1-1/2” x 3” (1 per stove)

45

H5571

Complete Baffle/Secondary Burn Tube Assembly 

(includes tubes and all mounting hardware) 

46

H8019

Baffle Blankets 15-1/4” x 12-1/2” x 1” - Two 

Included

47

H8018

Baffle Board Kit w/ Baffle Blankets

MISCELLANEOUS PARTS

71052

Dry Graphite (Apply to door handle and door 

hinges)

H5633

Anti Seize 2 gram pouch

REPLACEMENT PARTS - MODEL C210 AND CA210

Contact an IHP dealer to obtain any of these parts. Never use 

substitute materials. Use of non-approved parts can result in 

poor performance and safety hazards.

Summary of Contents for Performer C210

Page 1: ...ro de la pi ce 900102 00 This appliance must be properly installed and operated in order to prevent the possibility of a house fire Please read this entire installation and operation manual before ins...

Page 2: ...Chimney Requirements 10 Installation Procedures Masonry Chimney 10 Positive Flue Connection 11 Installation Procedure Factory Built Zero Clearance Fireplaces 11 Fireplace Pre Installation Preparation...

Page 3: ...by a professionalchimneysweep Donotattempttoburnoutheavy creosoteaccumulationswithahotfire Iflargeaccumulations are occurring review your burning procedures 14 If a creosote fire should develop the fi...

Page 4: ...ccessories may turn color stove glass may develop a haze which will not come off with cleaning Overfiring of a stove or fireplace insert is a condition where excessive temperatures are reached beyond...

Page 5: ...tion is essential when using a Solid Fuel Burning heater In well insulated and weather tight homes it may be difficult to establish a good draft up the chimney caused by a shortage of air in the home...

Page 6: ...f three burns The first two should last for 20 minutes each at 250 degrees the appliance should be allowed to cool completely between each burn The third should be a burn of at least 450 degrees F for...

Page 7: ...nstall the two remaining boards where you originally installed the first two boards on each side of the baffle support and pushed against the rear of the unit The stainless steel support hanger should...

Page 8: ...from the door opening of the unit Canada 18 450 mm minimum hearth extension on all stoves and inserts as measured from the door opening of the unit Minimum distance of floor protection to the side 8...

Page 9: ...asterisk indicates it is a value taken from Tables 2 and 3 FOLLOWING EXAMPLES ARE CALCULATED FOR USA REQUIRMENTS Using the k formula Minimum k value per Inch of Specified min thickness of alternate ma...

Page 10: ...nter of the fireplace opening and push it back until the surround brackets are approximately 2 51 mm away from the fireplace front 7 Install the side surround panels and push the insert up snug agains...

Page 11: ...pproved methods of achieving a positive flue connection See Figure 9 A qualified installer should evaluate the existing fireplace to determine the best method for achieving a positive flue connection...

Page 12: ...Factory Built Zero Clearance Fireplaces Fireplace Pre Installation Preparation NOTE IHP RECOMMENDS PROFESSIONAL INSTALLATION BY A LICENSED AND BONDED INSTALLER SEE YOUR DEALER FOR RECOMMENDATIONS IMP...

Page 13: ...Part H5296 is available to fill the space between the insert and the hearth protection Install the brick and baffle as per Page 7 Chimney Liner Installation Installing the Insert Post Installation Ch...

Page 14: ...ermometer can be a helpful tool to help ensure you are not over firing your appliance and it will also ensure you are burning fuel at a rate that is most efficient Place a stove thermometer on the top...

Page 15: ...turn off continue to rotate the knob counterclockwise until it clicks OFF Blower Speed Control Knob rheostat Manual Auto Rocker Switch Blower Operation Guidelines While in auto operation mode the blo...

Page 16: ...locate thermometer on the face of the insert just above the door Now load the firebox and set the draft control At this point you may need to burn the fireplace insert with the draft open for a few m...

Page 17: ...are included with the graphite CAUTION Cleaning Glass Ensure appliance is cold prior to cleaning glass A commercial glass cleaner designed for stoves is recommended Do not use abrasivecleaners Donotc...

Page 18: ...rotective gloves are recommended Step 5 Install New Glass Assembly Install the new glass with gasket in recess on door back use only factory supplied 5mm ceramic glass Do not substitute Step 6 Reinsta...

Page 19: ...ss above SMOKES WHEN 1 If smoke is entering the room check to make sure your baffle boards are properly installed DOOR IS OPEN and that the baffle blankets are pushed back flush with the front of the...

Page 20: ...requirements in your area Carbon Monoxide Monitor Recommended Carbon Monoxide Poisoning Early signs of carbon monoxide poison ing are similar to the flu with headaches dizziness and or nausea If you...

Page 21: ...dware 18 H8082 Replacement Power Cord 19 H8074 UHPII Blower Cage Snap Switch Black H8075 UHPII Blower Cage Snap Switch Gold H8076 UHPII Blower Cage Snap Switch Nickel H8077 UHPII Blower Cage Snap Swit...

Page 22: ...22 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 33 34 36 36 45 46 47 37 37 35 40 44 40 38 38 38 41 38 38 38 41 38 38 42 38 38 38 38 42 38 38 39 39 43 39 39 Replacement Parts Model C210 and CA210...

Page 23: ...23 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE 7 13 1 2 3 4 5 6 8 1 2 3 4 5 9 10 8 14 11 6 7 12 16 29 17 15 32 18 19 Replacement Parts Model C210 and CA210 Door Parts Blower Parts...

Page 24: ...N 71021 WFT2640 B Black 26 3 4 x 40 71022 WFT2648 B Black 26 3 4 x 48 71025 WFT3040 B Black 30 3 4 x 40 71026 WFT3048 B Black 30 3 4 x 48 71007 WFT2640 G Gold 26 3 4 x 40 71008 WFT2648 G Gold 26 3 4 x...

Page 25: ...a binder may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high efficiency EPA fireplaces are approved for burning d...

Page 26: ...a complete replacement parts list Use only parts supplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices a...

Reviews: