16
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Chimney
Termination
Rain Cap
Chimney
Termination
Rain Cap
Flashing
Flashing
Masonry Fireplace -
Built to UBC Chapter 37
Standards
Requires a minimum of a
positive flue connection
(Figure 12) in the USA.
In Canada, a full length
stainless steel flue liner is
required.
Approved Liner -
6” - 2100ºF HT Liner listed to
UL 1777 (US) or ULC S635
(Canada)
Remove Fireplace
Damper Or
Secure Open
Remove Fireplace
Damper Or
Secure Open
Flexible or Rigid 6”
Stainless Steel
Liner
Factory Built (ZC) Fireplace
Built to UL-127 (US) or ULC-
S610 (Canada) Standards
Requires a minimum of a
positive flue connection (Fig
-
ure 12) in the USA. In Canada,
a full length stainless steel
flue liner is required.
Approved Liner -
6” - 2100ºF HT Liner listed to
UL-1777 (US) or ULC-S635
(Canada)
Shown with offset
box installed
(see
Offset Boxes on
Pages 14 and 15
)
Secure liner to flue
outlet using three
sheet metal screws
Secure liner to flue
outlet using three
sheet metal screws
Flexible or Rigid 6”
Stainless Steel
Liner
Figure 15 - Typical Installation - Factory Built Fireplace
Figure 16 - Typical Installation - Masonry Fireplace
YOUR CHIMNEY INSTALLATION MUST COMPLY WITH LOCAL BUILDING AND FIRE CODES.
INSTALL VENTING SYSTEM PER VENT MANUFACTURERS INSTRUCTIONS!