ZProxy Server (available at zproxy.con.ru) allows the (proxied) connection between controller 

and  the  control  software,  where  direct  connection  is  impossible,  e.g.  if  the  controller  and  the 
software are in different LANs. If Internet access is available, 1) the controller connects to ZProxy 
server, 2) the control software connects to that server too, and 3) using a password, the control 
software requests connection to the required controller.

If no connection exists to control software, the controller will work in 

Standalone

 mode.

To configure controller functioning mode, use a jumper on the PCB, which can be set as follows:

· 

CONFIG

:  on  power-up,  the  controller  boots  into  setup  mode,  to  configure  connection 

parameters and equipment types.

· 

NORMAL

:  Normal  mode  –  the  connection  module  connects  to  LAN  as  configured,  the 

controller makes access control decisions. The existing connection parameters and connected 
equipment can be configured at a local IP address.

· 

LOCK

:  same  operation  as  at  NORMAL.  However,  both  the  Web  interface  for  connection 

parameters and connected equipment configuration, and data update in Web connection mode, are 
locked.

5.  WEB INTERFACE

The Web interface is used to configure connection parameters and connected equipment.
 You will require a device with a Wi-Fi network connection (smartphone, tablet or notebook), 
and an Internet browser (Internet Explorer, FireFox, Opera, Chrome etc.)
Launch the Web interface for controller configuration, via the following sequence:
1.  Set on-board jumper into CONFIG position.

2.   

Power up the controller.

Zproxy

Z-5R

WEB

Internet

>LOCK

>NORMAL

>CONFIG

Z-5R Web

www.ironlogic.

me

page 

8

Summary of Contents for Z-5R Web

Page 1: ...s that program the controller They only work for standalone controller programming and cannot be used for access Master keys allow to Add and erase Normal Blocking and other Master keys Set time for opening signal on locking device access control Activate and deactivate Accept Mode In Accept Mode any key is granted access but also is stored into controller memory as a Normal key This mode helps to...

Page 2: ...tedProtocols IP ARP TCP SSH ICMP UDP DHCP HTTP Wi Fi SupportedStandards IEEE802 11b g n FrequencyRange 2 4 2 4835GHz Transfer Rates 802 11n upto150Mbps 802 11g upto54M bps 802 11b upto11M bps W ireless signal power Upto20dBm 100mW W ireless operationmodes Access point Client W ireless security 64 128 512 bit WEP W PA W PA PSK W PA2 W PA2 PSK USB USBConnector type USBTypeA USBVersion USB2 0 USBMode...

Page 3: ...ON The controller dimensions are presented on this Figure Caution To avoid sharp edges in controller casing use saw to remove the tabs covering holes for leading wires through rather than breaking the tabs out manually Dimensions for controller mounting page 3 ...

Page 4: ...ield effect transistor drain No Designation Purpose 1 EX OPEN Input Evacuation mode Short circuiting this signal to GROUNDswitches theController into Evacuationmode 2 GROUND Common Ground wire for EX OPEN andDOOR signals 3 DOOR Input Door sensor When the door is closed must be short circuited to GROUND This terminal is multi functional and its function can bereassigned No Designation Purpose 1 ALA...

Page 5: ...ader input andDATA1 for reader output iButton mode reader input signal wire TM 4 12V Power to readers Output is protected against short circuiting for up to 200 mA Designation Purpose 1 BEEP Output signal for management of sound indication of readers Low level of asignal is active 2 RED Output signal for control of ared LED of readers The active is thelow level of asignal 3 GREEN Output signal for...

Page 6: ...ur Purpose WIFI Blue Wi Ficonnection status Solid ON Wi Finetworkconnected BlinkingON data transferin progress USB Green USB status Solid ON USB device connected BlinkingON data transferin progress LINK ACT Green Ethernet connection status Solid ON Ethernet physical connection between Z 5R WEB and thedevice on the other cable end usuallya switch Blinking Ethernetpackets being received MODE Yellow ...

Page 7: ...on mode The connection module attempts to connect to control software via TCP IP To configure this mode provide the IP address and port number of a remote PC running the control software such as GuardLight Avantgarde Авангард or Zproxy server Internet Ethernet Ethernet Z 5 R W E B Z 5 R W E B Ethernet Ethernet Ethernet Z 5 R W E B Z 5 R W E B Z 5 R W E B Wifi Wifi Z 5R Web www ironlogic me page 7 ...

Page 8: ...rs and equipment types NORMAL Normal mode the connection module connects to LAN as configured the controller makes access control decisions The existing connection parameters and connected equipment can be configured at a local IPaddress LOCK same operation as at NORMAL However both the Web interface for connection parameters and connected equipment configuration and data update in Web connection ...

Page 9: ...eb interface will still be available by the IP address which will either be manually assigned during initial configuration or automatically acquired from DHCPserver when registering onto the on site LAN If the Web interface is activated through the controller IP address a pop up authorisation window will appear Use z5rweb no quotes as your login and for password the 8 character AUTH_KEY value foun...

Page 10: ...ring the current connection session Jumper Position The current jumper position CONFIG NORMALor LOCK 5 3 Connection Setup Tab Connection Setup Tab allows setting up the network connection type and connection parameters Parameters configuration is similar to those of an Internet router 5 3 1 Ethernet If Ethernet connection type is selected the interface looks as follows If a DHCP Server is present ...

Page 11: ... by Save button 5 3 2 Wi Fi If Wi Fi connection type is selected the interface looks as follows SSID The SSID identifier of the Wi Fi network to connect to Security type Security type on this Wi Fi network WPA WPA2 None etc Security key Security key for this Wi Fi network Network Discovery Discover available Wi Fi networks IP Network parameters setup as for Ethernet connection type described above...

Page 12: ...ameters by pressing Save button 5 3 3 3G Modem If 3G modem connection type is selected the interface looks as follows Where Device Adrop down list of all available modems currently connected to device USB port The rest of parameters must be set according to your 3G modem documentation or obtained from your mobile operator APN Mobile operatorAccess Point Name Login Mobile operatorAccess login Passw...

Page 13: ...on module and control software Control Software Connection Mode tab allows to select the connection mode to the control software Where Authentication Key Required when connecting to a cloud based internet server or when working via a ZProxy server and for accessing the controller s Web interface Initially this field contains the factory pre set key found on a sticker on the back of device casing u...

Page 14: ... data transmission to Web server before the currentTransmission Interval has elapsed After setup is complete save the parameters by pressing Save button 5 4 2 Server In Server connection mode the connection module is listening for control software connection on a local port In this mode the following parameters need to be provided Where Local Port LocalTCPport listening for control software connec...

Page 15: ...to the controller After setup is complete save the parameters by pressing Save button 5 4 4 StandaloneThe initial ACS setup done by jumpers on other controllers on this device is performed in Standalone mode It works with controller keys database via Web interface no Master key needed Creating and modifying the keys database can thus be done in two ways First via Web interface Second using a speci...

Page 16: ...ten and lost 5 5 Controller Setup Tab Controller Setup tab allows to set up controller operational parameters Lock Type Electric Latch Electromagnetic or Electromechanical Readers Protocol Select key code transmission protocol For Wiegand protocol the controller automatically detects the bit width 26 34 42 or 50 FireAlarm Input Enables emergency door unlocking when EX OPEN input signal is asserted...

Page 17: ...please change the jumper position from CONFIG to NORMALor LOCK go toAdvanced Settings tab and choose the Reboot Controller function there 6 POWER UPAND GETTING STARTED Connect external devices to your controller as per Chapter 3 Factory default settings for Z 5R WEB module are as follows Use DHCP server Ethernet connection configuration Wi Fi protocol disabled Server software connection mode Local...

Page 18: ... To add new Keys keep touching the reader with them one after another ensuring that interval between touches does not exceed 16 s The reader will acknowledge each new touch by a short beep Hold a new key at the reader for 3 s and more for it to be written as a Blocking key otherwise Normal key If the presented key already exists in memory the controller will emit two short beeps To exit this mode ...

Page 19: ...y away from the reader Note When keys database is being erased via the Master key the existing programmed Lock OpeningTime setting is not erased 7 5 Set Lock Opening Time Touch the reader shortly four times with a Master key On each touch the controller will acknowledge the Master key emitting as many short beeps as the number of touch one for first touch two for second etc On fourth touch the con...

Page 20: ... Add Erase Keys modes do not persist after power is back on but normal operation mode is reactivated instead Note 2 When switching from standalone mode to network mode the control software usually overwrites existing keys database with the new keys database from the control computer Therefore we recommend saving existing keys database before connecting the controller to control software so it can ...

Page 21: ...AVS LLC 7 Bobruiskaya street Saint Petersburg 195009 Russian Federation E mail marketing rfenabled com Phone 78122411853 78125421185 www ironlogic ru Authorized representative in the European Union SIA IRONLOGIC 79A Slokas iela LV 1007 Riga Latvia E mail info ironlogic lv headstaff ironlogic lv Phone 37166181894 37124422922 www ironlogic me Z 5R Web www ironlogic me The symbol of crossed throught ...

Reviews: