Reader Connection Terminals Group
Reader Indication Terminals Group
Note: Connect both readers by the same protocol! Reader indication control is common for both
readers.
LED Indicators Layout on Controller's PCB
No Designation
Purpose
1
DATA1
-
Wiegand mode: DATA1 for reader input and DATA0
for reader output.
-
iButton™ mode: reader output signal wire (TM).
2
GROUND
Reader common wire connection.
3
DATA0
-
Wiegand mode: DATA0 for reader input and DATA1
for reader output.
-
iButton mode: reader input signal wire (TM).
4
+12V
Power to readers. Output is protected against short-circuiting
for up to 200 mA.
№
Designation
Purpose
1
BEEP
Output signal for management of sound indication of readers. Low
level of a signal is active.
2
RED
Output signal for control of a red LED of readers. The active is the low
level of a signal.
3
GREEN
Output signal for control of a green LED of readers. The active is the
low level of a signal.
Indicator
OPER
Indicator
CONN
Indicator
USB
Indicator
W
IFI
Indicator
LINK/ACT
Indicator
MODE
Indicator
STATUS
Z-5R Web
www.ironlogic.
me
page
5