Model 2100,2080,2000 Ver.14.0
7
Electrical installation requirements:
IMPROPER INSTALLATION MAY RESULT IN EQUIPMENT DAMAGE AND VOID THE WARRANTY
NOTE
:
DO not turn on electrical power to your spa until instructed in the owner manual.
1)
Improper electrical connections may damage the equipment, cause injury, a fire, and void your spa warranty.
We strongly recommend that only a licensed and bonded electrician perform the electrical installation.
2)
Installation must be in accordance with the National Electrical Code; local and state electrical codes; and the
manufacturer’s instructions. It is the responsibility of the spa owner to ensure a qualified electrician performs
the electrical installation.
3)
This equipment has been designed to operate on 230 or 380 volts, 50HZ alternating current.
4)
The spa must be connected to a dedicated branch circuit.
5)
IMPORTANT Note: Europe – R.C.D. Installation – circuit breaker, including ampere size and
selection of the conductor size and type must be performed by qualified electricians in accordance
with national Regional and Local codes and regulations in effect at the time of installation.
6)
As required, the electrical circuit to the spa must include a Class A type Ground R.C.D Interrupter.
7)
All supply wires must be copper and rated at a minimum 90.C
8)
Input Power Wiring and Circuit Breaker Selection
The Equipment Type column does not include the circulation pump for Silver series.
A jumper in the equipment control box configures the mode. In the HC 32 AMP 230 V or 2 and 3 phases Mode
the heater will operate with everything on in the spa. In the LC 16 AMP Mode the heater turns off if either pump
is in high speed or if the blower is turned on.
To hook-up your spa, follow these instructions:
1)
Remove the screws holding the equipment access panel to the front of the spa cabinet. Set the panel aside.
Instructions how to open see page 26.
2)
Loosen the 2 screws on the top of the front equipment control enclosure.
3)
Use- ―flexible, non-metallic conduit for a spa requiring #10 AWG or #8 AWG wire or 1‖ flexible
non-metallic conduit for a spa requiring #6 AWG wire. Run the conduit from the power source through the
hole in the left or right front corner of the enclosure into the equipment control box to the spa and secure /
seal with PG so no water can enter into the box.
4)
After pulling all wires through the conduit and into the equipment control box, connect them to the proper
terminals as indicated by the wiring diagram see Electrical service configuration for each system
Diamond/Gold or Silver versions.
5)
Configure the jumpers to the correct position as indicated by the
Electrical service configuration.
Ensure
the wires are properly tightened.
6)
Close the lid on the equipment control box and secure with the 2 screws.
7)
Electrical hook-up is now complete. Do not replace the equipment door at this point.