Chapter 4

– Using the Control Panel

4.4.8  Filter Life Reset (New Filter)

The Filter Life Reset function allows the Filter Life Monitor to be reset after a new
filter has been inserted. As a result, the appropriate filter life LED on the control
panel will be reset to green and the hour count in the Filter Life Reset display will
be reset to the full life span of the new filter. 

Note:

Resetting the Filter Life

Monitor will also cancel the “Replace Filter” warning from the main display
window.

Important:

To safeguard against inadvertently resetting the life of the wrong

filter, the filter selection needs to be confirmed twice by pressing the 

Enter 

key.

Refer to steps 4 and 5 below. If the wrong filter has been selected, or if you wish
to exit the Enter mode, press the 

Menu 

key. This will leave the Filter Life Reset

unaffected and return you to the Main display. 

Note: 

If no key is pressed for 15

seconds in a menu window, the display will revert to the main display window.

1.

To reach the Filter Life Reset function from the main display window, press
the 

Menu

key seven times.

2.

Press and hold the 

Enter

key until the flashing cursor appears. The first filter

selection to appear is the Pre-Filter. Release the 

Enter

key.

3.

Press the 

p

key to select the filter that has been replaced. The Filter Life LED

for the appropriate filter is currently flashing red.

4.

Press the 

Enter

key to confirm that the selected filter has been replaced. 

5.

To re-confirm the filter change, press the 

Enter

key.  To exit the Filter Life

Reset window, press the 

Menu

key.

6.

Upon successful reset of the filter life,   the new remaining filter life (taking the
currently selected fan speed into account) will be displayed, and the filter
LED light on the control panel will change from red to green. 

4.4.7  Time & Day Setting

When the IQAir system is first connected to the power, the day and time
displayed will be incorrect and will have to be set for the timer function to work
properly. Once the current day and time are set, they will only need to be reset
if the system is disconnected from the power supply for more than an hour.

1.

To access the Time & Day Menu from the main display window, press the

Menu

key six times.

2.

Press and hold the 

Enter

key until the cursor starts to flash. 

3.

Select the hour by pressing the 

p

key. 

4.

Press the 

Enter

key to save the hour setting and to proceed to the minute

setting.

5.

Select the minutes by pressing the 

p

key. 

6.

Press the 

Enter

key to save the minute setting and to proceed to the day

setting.

7.

Select the day of the week by pressing the 

p

key. 

8.

Press the 

Enter

key to save the day setting and to exit the enter mode.

9.

Press the 

Power

key to return to the main display. 

Note:

The display will

automatically return to the main window if no key is pressed for 15 seconds.

Summary of Contents for Cleanroom H 13

Page 1: ...Cleanroom H13 User Manual Swiss Made...

Page 2: ...nces Replacement cords are available from IQAir Only use this air cleaner for its intended purpose of air cleaning in non industrial environments Do not use this air cleaner in areas with very high co...

Page 3: ...4 4 4 Day of the Week Timer 14 4 4 5 Timer ON OFF Fan Speed Selection Menu 14 4 4 6 Timer Information in the Control Panel 15 4 4 7 Time Day Setting 16 4 4 8 Filter Life Reset New Filter 16 4 4 9 Cha...

Page 4: ...to cope with your room size The actual hourly air volume cleaned by the system should be at least double the air volume of your room If the rate at which pollutants enter the room air is high or the i...

Page 5: ...tto u 4 2 m e t s y l o r t n o c e d n a t e k p o t e h t n re se e S e S C e d le o a T D D ay D e m i T Ti l a u n a m r e s u e h t o t r e f re og r p o t d e r i qu e r s i k c o cl e h t g in...

Page 6: ...ntrally the system is positioned the better the performance Position the system close to a power outlet and make sure that the power cord is positioned in a way that it does not present an obstacle in...

Page 7: ...gn features air intake openings on two sides The Pre Filter module consists of frame 1 and the Pre Filter which is secured inside the frame by four filter clamps The fan assembly comprises two housing...

Page 8: ...culate air HyperHEPA filter media 5 Low turbulence low velocity air is returned to the room via the EvenFlow diffuser 8 Chapter 3 The IQAir System s Components 3 2 Description of Removable Components...

Page 9: ...and off Controlling the fan speed and corresponding air delivery rate Checking the remaining filter life of the individual filters Setting the automatic timer Resetting the Filter Life Monitor after...

Page 10: ...or a reduction in filter efficiency gas phase filter is saturated Fan Speed LEDs These LEDs simulate the fan speed through the frequency of their rotation The faster the rotation of the fan speed LED...

Page 11: ...et per minute x 60 air changes per hour ACH air volume of the room cu ft L x W x H Note The air delivery rates of the IQAir system at the various fan speeds settings are listed on the Technical Specif...

Page 12: ...lter is beyond its useful life a negative number will be displayed How the Filter Life Monitor Works The basis for calculating the remaining filter life is the already elapsed operation time at the se...

Page 13: ...rsor starts to flash 3 Press the p key one time to activate the timer Note If the START and STOP times are identical the timer cannot be activated Note The time is displayed in a 24 hrs clock military...

Page 14: ...n and exits the enter mode 4 4 4 Day of the Week Timer The Day of the Week Timer allows the deactivation of the Timer ON period on certain days of the week In its default setting the Timer ON period i...

Page 15: ...ng The first line shows the fan speed and the second line shows the airflow The Timer LED is off System on Standby The first line shows the current day and time and the second line shows the next time...

Page 16: ...ter Life LED for the appropriate filter is currently flashing red 4 Press the Enter key to confirm that the selected filter has been replaced 5 To re confirm the filter change press the Enter key To e...

Page 17: ...er mode 17 Chapter 4 Using the Control Panel 4 4 9 Changing the Airflow Units 1 You can reach the Airflow Units Menu by pressing the Menu key eight times 2 You can change the air volume units which ar...

Page 18: ...en set in the Weekly Auto Timer Menu it is possible to switch the timer on and off with the remote control To switch the timer on press the Timer Modification key and then the Timer ON key To switch t...

Page 19: ...r of minutes The illustration of the IQAir system on the control panel shows the positions of the individual filters These positions correspond to the actual positions of the filters within the system...

Page 20: ...s and push the locking arms inwards simultaneously until they snap back into the housing top of the diffuser IQ Air 20 Chapter 6 Replacing Filters Opening Closing 6 3 1 Troubleshooting When Closing th...

Page 21: ...me from the filter 10 Make sure that the filter is inserted all the way into the frame Insert the clamps into the sliding grooves inside the frame and push them down securing the filter into place 6 5...

Page 22: ...r at www iqair com support where you can find answers to most frequently asked questions FAQs or contact us with your inquiry To expedite your service request please have the following information rea...

Page 23: ...ng fixture you will also need a medium size flathead screwdriver How to install the power cord fixture 1 Disconnect the power cord from the wall outlet Plug the connector of the power cord into the ai...

Page 24: ...ng the supplied tool 7 8 6 9 Plug the red connector of the ribbon cable back into the control panel Ensure that it is pushed in all the way 10 Tuck the ribbon cable underneath and reinsert the control...

Page 25: ...of positive pressure if placed within the room and negative pressure if placed outside the room OutFlow Complete ducting adapter kit for the creation of negative pressure if placed within the room an...

Page 26: ...ly usage of 10h on speed 3 U S FDA registered as a Class II Medical Device Registration No 2087558 Performance 99 97 for particles 0 3 microns indiv tested at highest fan speed 99 5 at 0 003 microns y...

Page 27: ...27 Notes...

Page 28: ...www iqair com Swiss Made IQ_MA_CRH13_NE_US_130724...

Reviews: