OPERATION
Before starting
Wear personal protective equipment. See instructions
under the heading “Personal Protective Equipment”.
Make sure no unauthorized persons are in the working
area, otherwise there is a risk of serious personal injury.
Prevent unintentional starting of the motor by
ensuring the power switch is in the OFF position before
connecting the machine to a power source.
Check that the machine is assembled correctly and do
not show any signs of damage.
Before starting the vacuum verify your power supply
whether it be LOW (15 AMP) or HIGH (20 AMP) then set
the power supply selector on the appropriate setting.
This allows the iQ smart power management system
to know how many amps are available so the system
can manage the power and minimize trip circuit
breakers and downtime.
WARNING!
PLEASE READ THE OPERATOR’S
MANUAL CAREFULLY AND MAKE
SURE YOU UNDERSTAND THE INSTRUCTIONS BEFORE
USING THE MACHINE
6.1
CAUTION!
TO REDUCE THE RISK OF FIRE,
ONLY CONNECT A TOOL RATED
7.32AMP MAX TO THIS RECEPTACLE. RISK OF INJURY TO
PERSONS - TOOL SHOULD BE TURNED OFF BEFORE PLUG-IN
RISK OF INJURY – THIS IS A SWITCHED RECEPTACLE AND IS
ENERGIZED WHEN IQ426HEPA IS TURNED ON.
RISK OF INJURY – WHEN APPLIANCE CONNECTED TO
THIS RECEPTACLE IS TURNED ON, THE IQ426HEPA WILL
AUTOMATICALLY TURN ON.
WARNING!
TO REDUCE THE RISK OF ELECTRIC
SHOCK - DO NOT USE ON WET
SURFACES. DO NOT EXPOSE TO RAIN. STORE INDOORS.
STARTING MACHINE
To start the motor, engage the
POWER
switch
-
or on
symbol. Defective switches should be replaced by an
authorized service workshop.
STOPPING MACHINE
To stop the saw motor engage the
POWER
switch
O
or off symbol.
AUTOMATIC START FUNCTION
When you use the dust extractor together with
another power tool, there is an electrical outlet on the
dust extractor. Connect the power tool to this outlet.
When you start the power tool, the dust extractor will
also start. When you turn off the power tool, the dust
extractor will continue to run for approximately 10
seconds to empty the hose and then stop.
CLEANING YOUR IQ426HEPA
Only use a cloth to clean the dust extractor.
DO NOT use water.
• All equipment once used must be regarded as
contaminated and be treated thereafter.
• All parts that are contaminated after service
work must be disposed in a correct procedure
in plastic bags. Refer to local regulations.
• Use correct personal equipment when you
clean the product.
• Clean the filters and the dust extractor in
applicable area.
• Do not use water on electrical components.
• Do not clean the dust extractor with high
pressure (air or water).
• Do not put tools on the surface of the filter,
it can cause damage to the filter.
• Do not make a hole in the HEPA filter, it can
cause a health risk.