Summary of Contents for iQ426HEPA

Page 1: ...d the iQ426HEPA Operator s Manual in your language Please read the operator s manual carefully and make sure you understand the instructions before using the machine Cyclonic Dust Extractor With HEPA Filtration For light industrial and indoor use only ...

Page 2: ...M iQ426HEPA 001 0M112019 ...

Page 3: ...tools com English TABLE OF CONTENTS Safety Machine Labels Introduction What Is What Assembly Operation Filter Maintenance Dust Disposal Cart Transport and Storage Troubleshooting Technical Data Warranty Policy 1 2 3 4 5 6 7 8 9 10 11 12 13 Topic Section ...

Page 4: ... your body away from openings and moving parts k Turn off all controls before unplugging l Use extra care when cleaning on stairs IMPORTANT SAFETY INSTRUCTIONS m Do not use to pick up flammable or combustible liquids such as gasoline or in area where they may be present n For grounded appliance Connect to a properly grounded outlet only See grounding instructions o For a vacuum cleaner 1 Do not pi...

Page 5: ...ble for outdoor use Use of a cord suitable for outdoor use reduces the risk of electric shock Keep the connection to the extension cord dry and off the ground Keep cable away from heat oil sharp edges or moving parts Damaged or entangled cables increase the risk of electric shock Check that the cord and extension cord are intact and in good condition Never use the machine if any cable or plug is d...

Page 6: ... for picking up dry non flammable dust and debris in an indoor environment It is not suitable for picking up liquids Do not pick up any type of liquids Do not allow a build up of dust hair and 1 3 GENERAL SAFETY PRECAUTIONS This section describes basic safety directions for using the machine This information is never a substitute for professional skills and experience Please read the operator s ma...

Page 7: ...f the cord and never pull out the plug by pulling the cord Hold the plug to disconnect the power cord Never use the machine if any cable or plug is damaged but hand it in to an authorized service workshop for repair Prevent unintentional starting of the motor WARNING WHEN CLEANING THE MACHINE MAKE SURE TO AVOID WATER ENTERING THE ELECTRICAL SYSTEM AND THE MOTOR UNIT WATER CAN CAUSE DAMAGE TO THE M...

Page 8: ...urroundings if the instructions in the manual are not followed Used if there is a risk of damage to materials or the machine if the instructions in the manual are not followed NOTICE 2 1 Always wear hearing protection Always wear protective goggles and or a visor High voltage Risk of an electric shock Turn off machine and unplug before transportation CSA approved 248014 CU S International Symbols ...

Page 9: ...tor s manual so they will also know how to properly maintain and use it Owner Responsibility It is the owner s employer s responsibility to ensure that the operator has sufficient knowledge about how to use the machine safely Supervisors and operators must have read and understood the Operator s Manual They must be aware of The machine s safety instructions The machine s range of applications and ...

Page 10: ...ust Collection Tub 4 Visible Window 5 Cyclones Frontside 4 1 6 Tub Latch 7 Vacuum Hose Connection 8 Electric Tool Power Outlet 9 Vacuum Housing Handle 10 Vacuum Housing Lift Latch 11 Accessory Rack 12 Power Supply Selector 13 On Off Switch 14 Vacuum Motor 15 Release Lever 8 7 10 6 5 3 2 1 11 12 13 9 14 15 4 ...

Page 11: ... 7744 www iqpowertools com English 16 Cart Handle 17 Cyclones 18 Filter Spin Knob 19 Cart Caster WHAT IS WHAT 4 2 20 Cart 21 Cart Wheel 22 Cart Handle Latch Release 23 Accessory Rack 24 Hose End Holder Backside 16 17 21 20 19 18 23 22 24 ...

Page 12: ...ww iqpowertools com English WHAT IS WHAT Side 25 Cart Handle 26 Cord Wrap Hook 27 Electrical Tool Power Outlet 28 Tub Latch 29 Cart 30 Filter Spin Knob 31 Accessory Rack 32 Vacuum Housing Lift Hook 33 Vacuum Inlet 4 3 25 26 27 28 29 30 32 31 33 ...

Page 13: ...rt 34 HEPA Filter Cover 35 Back Tub Latch 36 Current Overload Switch 37 HEPA Filter Status Light 38 On Off Auto Switch 39 OFF 40 ON 41 Auto ON with Electric Tool Outlet 42 Power Supply Selector HEPA 20A 15A Control Panel 4 4 HIGH LOW WHAT IS WHAT 34 35 38 36 37 42 41 40 39 ...

Page 14: ...ce preferably a workbench to prevent the equipment from tipping or sliding during assembly ATTACHING CART WHEELS Gather all pieces for the wheels This includes 4 washers 2 bolts 2 spacers Put one spacer in the center hole of the wheel With washer already on the bolt feed the bolt through the spacer Put a second washer on the other side of the bolt Take wheel and feed bolt into the hole on the cart...

Page 15: ...xtractor and place on a flat horizontal and stable surface preferably a workbench to prevent the equipment from tipping or sliding during assembly ATTACHING RACK Gather all pieces for the rack This includes 1 rack 2 end caps and 8 screws Hold rack on the outside of the cart While holding rack place the end cap on the front side Use 4 screws to tighten rack Repeat for the other side Included Access...

Page 16: ...ONNECTED TO THIS RECEPTACLE IS TURNED ON THE IQ426HEPA WILL AUTOMATICALLY TURN ON WARNING TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT USE ON WET SURFACES DO NOT EXPOSE TO RAIN STORE INDOORS STARTING MACHINE To start the motor engage the POWER switch or on symbol Defective switches should be replaced by an authorized service workshop STOPPING MACHINE To stop the saw motor engage the POWER switch O ...

Page 17: ...cian or service person if you are in doubt as to whether the outlet is properly grounded Do not modify the plug provided with the appliance if it will not fit the outlet have a proper outlet installed by a qualified professional For grounded cord connected appliance rated less than 15 A and intended for use on a nominal 120 V supply circuit the instructions in either 1 or 2 1 The appliance is for ...

Page 18: ...ter REPLACING THE IQ DURABOND FILTER Spin filter knob 5 times to ensure all dust is released While dust settles remove the 5 screws around the filter cover Remove filter cover and filter Put in new filter and cover with filter cover Note the cover should be attached at the same position as in image below Replace the 5 screws REPLACING THE HEPA FILTER When the HEPA filer light turns red it is time ...

Page 19: ...uirements and applicable regulations When the product no longer is being used discard it at a recycling location DUST DISPOSAL Each iQ426HEPA will come out of the box with 3 bags The bags come with an attached tie to ensure closure when disposing of dust Replacement bags are available to purchase with your dealer or at iqpowertools com DUST TUB COLLECTION BAG INSTALLATION Install bag hooking band ...

Page 20: ... com vacuum dance REMOVING THE IQ426HEPA DUST TUB FROM CART Step 1 Start by spinning filter 3 5 times It is important to clean the filter before emptying the dust tub NOTE Machine must be turned off before cleaning filter Step 2 Un hook the latches at the front and back of the dust tub by pressing down and then out Step 3 Step on the release lever at the bottom of the cart while pushing the cart h...

Page 21: ... not sure about how to lift heavy equipment Attach the product safely during transportation in order to prevent transport damage and accidents If possible use a closed vehicle during transportation of the product Storage The product must be stored inside away from outdoor elements Do not expose the product to rain or moisture Disconnect the product from the power source Store the product and the e...

Page 22: ...WHAT TO DO 1 The hose is not connected 1 Connect the hose 2 The hose is blocked 2 Unblock the hose 3 The cyclones and or vacuum is blocked 3 Clean the cyclones and or vacuum passages TROUBLE THEMOTORRUNSBUTSUCTIONISPOOR WHAT S WRONG WHAT TO DO 1 There is a hole in the hose 1 Replace the hose 2 The filter is clogged 2 Clean or replace the filter 3 The top cover is misaligned 3 Adjust the cover to t...

Page 23: ...TER DURABOND CARTRIDGE AREA SQR FT M2 8 74 HEPA FILTER 99 97 AT 0 3 µM TOTAL HEPA FILTER AREA FT2 M2 37 034 DUST COLLECTION TUB TUB WITH OPTIONAL PLASTIC BAG FILTER CLEANING MECHANISM SPIN CLEAN WHEN MACHINE IS EMPTIED SOUND PRESSURE LEVEL LPA AT THE OPERATORS EAR DB A 2 84 5 POWER CORD IN MM 18 457 DIMENSIONS WEIGHT LB KG 60 27 CART WEIGHT LB KG 23 11 DIMENSIONS W x H x L INCH MM 23 x 41 x 34 584...

Page 24: ...AGRAM 12 2 Incoming Current Selector Rocker Switch Receptacle Over Load Indicator LOAD LINE 15A 120VAC 120VAC 60Hz 1 Overload Instruction J4 2 J4 1 Red Red Red White N Black L Black White MT_V1 MT_V2 White Black Black Red Black Black White Red L1 L2 N1 SK_N SK_L B2 2 B1 A2 A1 LED ...

Page 25: ...or freight or other transportation related costs or expenses in connection with any defective products replacements or components that are returned to iQ Power Tools facility or any authorized repair station WARRANTY Parts and labor needed to maintain products and the replacement of components due to normal wear and tear are the purchaser s responsibility and are not covered by this Warranty All p...

Page 26: ...iQ426HEPA Operator s Manual 888 274 7744 www iqpowertools com English NOTES ...

Page 27: ...888 274 7744 WWW IQPOWERTOOLS COM ...