23
12. To adjust the gates closed limit, rotate programming knob clockwise until “I-M-1 Close Limit is #### “ is
displayed. Increase this number to close the gate further or decrease the number to stop the gate
sooner.
13. To adjust the soft stop position, rotate the programming knob until “I-M-1 Slow Down at 80%” is
displayed. To adjust the gate so that it slows down from full speed at a sooner position, lower the
percentage. To slow the gate down later in its full cycle, increase the percentage.
14. When finished, scroll clockwise until “Exit the sub-menu” and push the programming knob to enter.
15. Scroll counter-clockwise to the current date and time to exit the menu
16. Once the gates open and closed limits have been set, it is recommended that you adjust the cam that is
closest to the close limit and move that cam until it activates the closed limit. This is how the Limit
Secure or “fail secure” feature is obtained.
17. If you desire to change the rate of the soft start or soft stop, you can do so by adjusting the rate of
acceleration or deceleration in the “Motor Drive Menu”
18. It is highly recommended that you verify the motors running amperage so that you can properly adjust
the maximum amperage force for each motor. To do this, rotate the programming knob from the date
and time clockwise until the display reads “Maintenance Menu” and push enter to adjust. Scroll
clockwise until the display reads “Motor Diagnostics – View for M1 Off”. Press the programming knob
to enter and the programming
*
will be displayed. Rotate the knob until “ON” is displayed, press the
programming knob again so that the
*
disappears and then rotate the programming knob clockwise until
“Exit the sub-menu” and push the knob to exit.
19. From here, rotate the programming knob counter-clockwise until the date and time is displayed. Using
the RADIO button or any desired open contact, operate the gate and view the amperage. When the
operator is not running, the previous highest amperage and lowest voltage requirements will be
displayed. By using this information, you can adjust the motor amperage in the “Motor Drive Menu”
accordingly.
20. Return to the “Maintenance Menu” and turn of the “Motor Diagnostics” for each motor when you no
longer need them displayed.
At this point, the IQ-5000-S has been learned and may be operated. Remember to disconnect all batteries and
power via the On/Off switch before and during any accessory wiring. You may also reconnect any magnetic or
other gate locks. If the install is going to consist of a “master and slave” configuration, you can learn M-2 at this
time. You may also set any desired open and close leaf delays to assist in a master/slave configuration in the
“Motor Drive Menu”.