Product Description of BRT-606

Page 3 of 5

Shenzhen Asia Bright Industry co., Ltd., Building 10, Asia Industrial Park, Gangtou, Bantian, Shenzhen, China.

www.a-brt.com

[email protected].

© 2015 All rights reserved. Subject to change without notices.

Fig. 4 shows the remote control set. Each of the buttons can be used as an on/off button. Although

there are 6 buttons on the remote, only two buttons are needed to control one BRT-606 wall mount

unit. The remote set can be set to control up to three BRT-606 wall mount units. Please refer to

BRT-606 Timer Switch Setup” for details.

Specification Parameters:

Input Voltage

220

240V(50Hz/60Hz)

Operation

Environment

No-condensation 20-90% RH

-20

℃~

55

Wattage

1000W/Loads

Load type

All Types

Mounting Hole

Spacing

60mm

Matching

Box

75mm x 75mm x 50mm

Wall Mount

Unit Dimension

86mm x 86mm x 43mm

Wall mount

Unit Weight

112g

Remote Set

Dimension

102mm x 43mm x 13mm

Remote Set

Weight

33g

Wiring Diagram and Installation Guide:

The wall mount unit of BRT-606 timer switch requires both hot wire and neutral wire for

installation:

Hot wire (ACL):

Coming from the power line with 220V;

Neutral wire (ACN):

Usually coming with the hot wire;

Load wires:

Going to the load.

Fig. 5

Wiring Diagram of Wall Mount Unit

Warning:

Please make sure power is turned off before starting installation!

Fig. 5 shows the wiring diagram and Fig. 6 shows the step-by-step installation instructions. There

are three easy steps:

Summary of Contents for BRT-606

Page 1: ...unt unit is designed for easy installation and retrofit directly fit into standard wall box Two buttons to control two loads respectively Hidden keypad panel for timer settings Delay off time up to 30 minutes which can be set accurately to a second Remote control distance up to 15m LCD display showing the current time and the current status of the switch Good for all kinds of loads Resistive induc...

Page 2: ...button is pressed The display shows On and the load will be turned on immediately and When the On Off button is presses again the display will show Off and If there is no delay off time being set the load will be turned off immediately or If there is delay off time being set the load will be turned off only after the preset delay off time runs out Meanwhile the display will show a bell sign Press ...

Page 3: ... 240V 50Hz 60Hz Operation Environment No condensation 20 90 RH 20 55 Wattage 1000W Loads Load type All Types Mounting Hole Spacing 60mm Matching Box 75mm x 75mm x 50mm Wall Mount Unit Dimension 86mm x 86mm x 43mm Wall mount Unit Weight 112g Remote Set Dimension 102mm x 43mm x 13mm Remote Set Weight 33g Wiring Diagram and Installation Guide The wall mount unit of BRT 606 timer switch requires both ...

Page 4: ...played hours will flash and then press or to adjust the hours Press the SET button again the displayed minutes will flash and then press or to adjust the minutes Press the SET button again the displayed date will flash and then press or to adjust the date Finally press the SET button to finish and the settings are saved 4 Set up Delay off Time The delay off time of the two loads can be set separat...

Page 5: ... top edge Press and hold I button for 2 seconds until the display shows Then press one of the 6 buttons on the remote until disappears This button is now set up to control the first load specifically The synchronization process can last up to 20 seconds Another remote button can be synchronized to control the second load by usingⅡbutton Applications BRT 606 timer switch kit can be used for automat...

Reviews: