- LIK50
Description & Installation
Issue
1.2.1
47
4.4.4.8 Module Installation Sequence
A
SEQUENCE NUMBER
is assigned to gateway modules based on the sequence of registration with
the system, refer to the
iPECS Admin & Program Manual
for further details. This
SEQUENCE
NUMBER
determines the logical CO Line and station numbers assigned in the system database.
Although the
SEQUENCE NUMBER
in the database can be changed, connecting the gateway
Modules to the iPECS in the desired sequence based on type of Module is recommended. The
Module
SEQUENCE NUMBER
can be easily established at installation by controlling the order of
connection of the
Module’s LAN port to the system.
Station numbers are also assigned consecutively based on the order of connection to the system.
Since the first phone installed is assigned as the Admin Station (station number 100), it is
recommended an LIP Phone be connected to the system prior to installing any SLT gateway
Module.