Table 3.1-1  System Capacities

 

 

 

CAPACITY

 

LIK-MFIM50A

 

LIK-MFIM50B

 

LIK-

 

System Capacity

 

50

 

50

 

31

 

Stations 

*1

 

50

 

50

 

26

 

 

PSTN/ISDN circuits*2

 

42 

( Basic: 4 PSTN +VoIP)

 

42 

( Basic: 4 ISDN-BRI +VoIP)

 

(Basic: 5 VoIP)

 

Max. RSGMs *3

 

25

 

25

 

13

 

Attendants

 

4

 

4

 

4

 

Serial Port (RS-232C)

 

1

 

1

 

0

 

USB Host port

 

1

 

1

 

1

 

Alarm/Door bell input

 

1

 

1

 

0

 

External Control Relays(s)

 

1

 

1

 

0

 

Music Source Inputs

 

1

 

1

 

0

 

Power Fail Circuit (PFT) *4

 

1

 

0

 

0

 

External Page Zones

 

1

 

1

 

0

 

Internal Page Zones

 

10

 

10

 

10

 

System Speed Dial

 

800 (48 digits)

 

800 (48 digits)

 

800 (48 digits)

 

System  Speed  Dial  Zones 
(Groups)

 

 

10

 

 

10

 

10

 

Station Speed Dial

 

20 (48 digits)

 

20 (48 digits)

 

20 (48 digits)

 

Last Number Redial

 

10 (48 digits)

 

10 (48 digits)

 

10 (48 digits)

 

Save Number Redial

 

1 (48 digits)

 

1 (48 digits)

 

1 (48 digits)

 

DSS Consoles/Station

 

9

 

2

 

3

 

 

 

Note 1   2 FXS ports are provided in LIK-MFIM50A/B as standard.

 

Note 2   4 FXO (Analog CO/ 4 FXD (ISDN-BRI) ports are provided on LIK-MFIM50A/LIK-MFIM50B standard, 
respectively.

 

Note 3   For  maximum  RSGM  connection  ports,  calculation  formula  is  =  (available  station  ports)/2,  there 

must be enough VoIP channels for RSGM operation.

 

Note 4   1 PFT circuit is provided on LIK-MFIM50A only. It is connected between FXS port 1 and FXO port 1.

 

Summary of Contents for LIK-MFIM50A

Page 1: ...IPECS 50A 50B Hardware Description Installation Manual...

Page 2: ...nstallation Issue 1 2 1 ii Update Revision History ISSUE DATE DESCRIPTION OF CHANGES 1 0 JUL 2008 Initial Release 1 1 Oct 2009 Manual is merged 1 2 Aug 2010 Changed the new CI LG Ericsson 1 2 1 Jun 20...

Page 3: ...LIK50 Description Installation Issue 1 2 1 iii CD Manual Revision History ISSUE DATE DESCRIPTION OF CHANGES 1 3 5 Oct 2009 Manual is merged 1 5 Aug 2010 Changed the new CI LG Ericsson...

Page 4: ...to the user allowing the user to take appropriate steps to maintain telephone service iPECS LIK50 comply with rules regarding radiation and radio frequency emission as defined by local regulatory agen...

Page 5: ...mount Holder Extender 20 2 3 2 WHLD Wall mount HoLDer 21 2 3 3 1URMB 1U Rack Mount Bracket 21 2 4 Software Components 22 3 System Specifications 23 3 1 System Capacity 23 3 2 Dimension and Weight 24 3...

Page 6: ...on 35 4 4 3 38 4 4 4 General Installation 41 4 4 4 1 Miscellaneous Connections 41 4 4 4 2 Telephony FXS FXO Connections 41 4 4 4 3 BRI Line Connections 42 4 4 4 4 LAN Connections 42 4 4 4 5 LAN Wiring...

Page 7: ...LIP Phones commonly used features are activated by selection of a single button Additionally most functions can be accessed from any telephone by dialing specific codes For LIP and digital Phone user...

Page 8: ...r the life of the system The reliability extensive feature content the ability to support present and future applications with the iPECS Feature Server and the capability to use an array of modules an...

Page 9: ...LIK50 Description Installation Issue 1 2 1 3 Figure 1 1 2 below is a diagram of the system terminals and applications available with iPECS LIK50B Figure 1 1 2 iPECS LIK50B Structure...

Page 10: ...LIK50 Description Installation Issue 1 2 1 4 Figure 1 1 23 NA Figure 1 1 3 NA...

Page 11: ...e 24 button 3 line display w Menu Soft Nav buttons 12 LIP 7024LD LIP Phone 24 button Large display w Menu Soft Nav buttons 13 LIP 7048DSS LIP DSS Console with 48 buttons 14 LIP 8002 LIP Phone 4 button...

Page 12: ...tery to maintain the real time clock and prevent loss of system database during power fail refer to section 4 4 1 4 4 2 There are two types of MFIMs as shown in Table 2 1 1 1 Table 2 1 1 1 LIK MFIM50...

Page 13: ...upports four 4 ports and there are two versions based on protocol LIK CMU1216 CMU 50PR Each version is for different regions as shown below 1216 Australia Denmark Italy Spain Sweden Belgium India Isra...

Page 14: ...ax over IP A ring generator and message wait source are integrated FXS allows Single Line Telephones to be connected up to 4 Kilometers 13 000 feet from the gateway using 24 AWG wire MFIM50B have a fr...

Page 15: ...LIK50 Description Installation Issue 1 2 1 9 This page intentionally blank...

Page 16: ...ionally relevant AC blade type The adapter supports AC input power systems with rated voltage range of 100 240 VAC 50 60 Hz The adapter provides 12 VDC 1 5A amps The DC output connector is cabled to t...

Page 17: ...e 12 button 3 line display w Menu Soft Nav buttons LIP 8024D LIP Phone 24 button 4 line display w Menu Soft Nav buttons LIP 8040L LIP Phone 10 button 9 line display w Menu Soft Nav buttons LIP 8048DSS...

Page 18: ...8000 phone Up to four 4 48 button consoles may be connected in a daisy chain to one LIP 8000 phone The LIP8048DSS is powered from an AC DC adapter only Each LIP 8000 series IP phone has a standard 12...

Page 19: ...as tone generation and speakerphone operation Note the LIP 8804D does not include speakerphone operation The Volume controls which consist of separate volume up down buttons adjusts the level of the h...

Page 20: ...LIK50 Description Installation Issue 1 2 1 14 Figure 2 2 1 2 LIP 8004D Figure 2 2 1 2 LIP 8012D Figure 2 2 1 3 LIP 8024D...

Page 21: ...LIK50 Description Installation Issue 1 2 1 15 Figure 2 2 1 4 LIP 8040L Figure 2 2 1 5 LIP 8012DSS...

Page 22: ...LIK50 Description Installation Issue 1 2 1 16 Figure 2 2 1 6 LIP 8012LSS Figure 2 2 1 7 LIP 8048DSS...

Page 23: ...ected to an intelligent 10 100 Base T switch which gives LAN access to the data device while giving priority to voice packets The LIP 7048DSS Console which is used to expand the number of Flexible but...

Page 24: ...Processing to implement packet voice encoding and decoding and echo cancellation as well as tone generation and speakerphone operation The Volume control which consists of a single volume up down rock...

Page 25: ...LIK50 Description Installation Issue 1 2 1 19 Figure 2 2 2 3 LIP 7016D Figure 2 2 2 4 LIP 7024D Figure 2 2 2 5 LIP 7024LD Figure 2 2 2 6 7000 Series Phones Wall Mount Bracket...

Page 26: ...3 1 AC DC Adapter for LIP Phones Console 2 3 MOUNTING HARDWARE MODULE LIK MFIM50A B can be installed in several different manners Desk mounted using the Desk Mount Holder Wall mounted individually usi...

Page 27: ...lder shown in Figure 2 3 2 1 The WHLD provides wall mounting for a single module Figure 2 3 2 1 Module Wall Mount Holder 2 3 3 1URMB 1U Rack Mount Bracket LIK MFIM50A B can be individually wall mounte...

Page 28: ...ffered include iPECS Phontage PC SoftPhone iPECS Phontage PDA SoftPhone iPECS TSP MSP TAPI 3 1 iPECS Auto Attendant Voice Mail iPECS Unified Messaging Services iPECS ez Attendant iPECS Networking iPEC...

Page 29: ...Zones 10 10 10 System Speed Dial 800 48 digits 800 48 digits 800 48 digits System Speed Dial Zones Groups 10 10 10 Station Speed Dial 20 48 digits 20 48 digits 20 48 digits Last Number Redial 10 48 di...

Page 30: ...able 3 3 1 Environmental Specifications DEGREES 0 C DEGREES 0 F Operation Temperature Optimum Operation Temperature Storage Temperature Relative Humidity 0 40 32 104 20 26 68 78 20 60 4 140 0 80 non c...

Page 31: ...m AWG 24 0 5mm 3 US REN US 7K model 25Hz FXO Connector REN Ringer Equivalent Number RJ 45 0 7B ISDN BRI Connector Network Type RJ 45 T interface 3 4 3 Maximum Station Distance from Gateway Module Tabl...

Page 32: ...etect Sensitivity Min 20 Vrms 16 67 Hz DTMF Dialing Frequency Deviation Signal Rise Time Tone Duration on time Inter digit Time Less than 1 8 Max 5ms Min 65 ms Min 65 ms Pulse Dialing Pulse Rate Break...

Page 33: ...cuit breaker or fuse rated at 1 A and must be surge protected An appropriate grounded outlet should be within approximately 2 meters 6 feet of the equipment location When employing the Desk Mount Hold...

Page 34: ...Check that the type and quantity of Modules and terminals received are correct Also assure optional equipment and Power Line Surge Protector are on site The individual Modules and terminals need not...

Page 35: ...ting Module in Wall Mount Holder 4 3 3 1U Rack Mount Bracket Installation The Module 1U Rack Mount Bracket will house a single Module and an AC DC adapter to power the Module To install refer to figur...

Page 36: ...ect the adapter plug refer to Figure 4 3 3 2 Slide the Module into the 1U RMB Connect the adapter DC plug to the LIK MFIM50A B Tighten the DC cable using the cable tie Figure 4 3 3 2 Mounting Module i...

Page 37: ...A Installation LIK MFIM50A can be installed in the Desk Mount Holder Wall Mount Holder and 1U Rack Mount Bracket LIK MFIM50A contains a long life Lithium battery which protects the memory and real tim...

Page 38: ...tries are complete place the switch in the ON position When new gateway Modules and or terminals are connected to a LAN they will automatically attempt to register with an LIK MFIM50A With the Registr...

Page 39: ...e procedure for installing a LIK CMU unit on the LIK MFIM50A Check the connector numbers of the LIK CMU unit prior to installation Figure 4 4 1 1 Installing a LIK CMU unit on LIK MFIM50A Table 4 4 1 3...

Page 40: ...hony connectors are terminated as shown in 4 4 4 1 and section 4 4 4 2 respectively Wire Miscellaneous function connectors as depicted in the sketches of Figure 4 4 1 3 Wire the FXO FXS telephony port...

Page 41: ...ch Settings MFIMs have a four 4 position DIP switch identified as the MODE switch The function of each switch position is given in Table 4 4 2 2 below Table 4 4 2 2 MFIM50B MODE Switch Functions Name...

Page 42: ...is pressed Note if the system looses power for any reason with the switch in the ON position the database will be initialized Place the switch in the ON position then after completing the system wiri...

Page 43: ...ction 4 4 4 3 and section 4 4 4 2 respectively Wire Miscellaneous function connectors as depicted in the sketches of Figure 4 4 2 2 Wire the FXS telephony ports as shown in Figure 4 4 2 2 Wire the ISD...

Page 44: ...LIK50 Description Installation Issue 1 2 1 38 4 4 3 Blank BLANK...

Page 45: ...LIK50 Description Installation Issue 1 2 1 39 BLANK...

Page 46: ...LIK50 Description Installation Issue 1 2 1 40 BLANK...

Page 47: ...pre mature failure and or faulty operation of the equipment 4 4 4 1 Miscellaneous Connections Miscellaneous connections are via RJ 45 type jacks in the rear of LIK MFIM50A MFIM50B are wired as in Figu...

Page 48: ...LAN speed LED On for 100 Base T The gateway Module LAN ports and the POE8 UPLINK ports as well as the LIP Phone LAN port are terminated in the standard Media Dependent Interface MDI configuration show...

Page 49: ...Figure 4 4 4 4 1 Pin Assignments of LAN Connector RJ 45 4 4 4 5 LAN Wiring Structure The LAN wiring architecture used for connecting iPECS Modules to the LAN is dependent upon several factors includi...

Page 50: ...hared environment support for remote LAN power and external VoIP calling the POE8 which is a standard Ethernet switch should be employed The recommended structure called here hierarchal wiring employs...

Page 51: ...tor located on the front panel of LIK MFIM50A MFIM50B is an RS 232 serial port The connector is employed to provide system trace and diagnostic routines for the individual Modules The MFIMs have one s...

Page 52: ...Terminal Ready DSR Data Set Ready Figure 4 4 4 6 1 RS 232 DB 9 Pin outs 4 4 4 7 Module Grounding As shown in Figure 4 4 4 7 1 a or screw is located on the rear panel of each Module For proper operatio...

Page 53: ...NUMBER in the database can be changed connecting the gateway Modules to the iPECS in the desired sequence based on type of Module is recommended The Module SEQUENCE NUMBER can be easily established a...

Page 54: ...ice or data traffic The LAN port is connected to the LAN as described above for the single port Phones The PC port is connected to a desktop device using any standard straight through category 5 cable...

Page 55: ...ting Remove the Handset hook from the phone as shown in the figures below Reverse the hook and re install in the LIP 8000 phone so that the hook catches the groove in the handset receiver Figure 4 5 1...

Page 56: ...alling LIP 8000 DSS consoles 1 The AC DC adapter must be used for LIP 8048DSS 2 Up to two 2 LIP 8012LSS and or LIP 8012DSS can be installed with LIP 8000 Phone 3 The LIP 8048DSS must be separately pow...

Page 57: ...LIK50 Description Installation Issue 1 2 1 51 Figure 4 5 4 LIP 8000 DSS Installation 12DSS 12LSS Figure 4 5 5 LIP 8000 DSS Installation 12DSS 12LSS 48DSS...

Page 58: ...Refer to Figure 4 5 6 Slide the Wall Mount bracket over the screws and tighten securely Connect a short Cat 5 cable to the LIP 24D DH or LIP 7000 series Phone and the wall jack Mount the LIP 24D DH o...

Page 59: ...Software Notice This following GPL General Public License software used in this product are subject to the GPL License Agreements You can obtain a copy of the GPL licenses from LG Ericsson Web Site h...

Reviews: