10
PC-Link Programming:
(Only needed if sending signals via PC-Link)
DSC Programming for Communications - GSM Emulation: If GSM is used, it must be in dialer capture mode.
Sec
BAT LTE as
Sole
Communicator
BAT LTE as Fail
over w/Add’l
Communication
Device
BAT LTE as Dual
Reporting w/Add’l
Communication
Device
Code Summarization
015
Disable Option
7
If GSM: Disable
Option 7 If
Phone Line,
Enable Option 7
If GSM: Disable
Option 7 If Phone
Line, Enable Option
7
Option 7 turns on/off
telephone line supervision.
167
Set ‘060’
Seconds
Set ‘060’
Seconds
Set ‘060’ Seconds
Sets T-Link acknowledgment
delay to 60 secs.
301
Set ‘CAAF’
Set ‘CAAF’
Set ‘CAAF’
‘CAAF’ has to be set for the
panel to send signals to the
PC- Link
302
N/A
N/A
Set ‘Central Station
Receiver #’
Second telephone number
goes here.
303
N/A
Set ‘Central
Station Receiver
#’
Set ‘Central Station
Receiver #’
This section is the telephone
backup of section 301.
350
Set ‘04’/‘04’
Set ‘04’/’03 for
Contact ID, 04
for SIA FSK’ **
Set ‘04’/’03 for
Contact ID, 04 for
SAI FSK’ **
Format sent as either contact
ID (03), or SIA FSK (04). The
PC-Link/BAT LTE can ONLY
receive signals via SIA FSK
(04).
351
Enable Option
1
Enable Option
1, 5
Enable Option 1,
2, 5
Options to turn on/off
alarm/restore for telephone
1 (option 1), telephone 2
(option 2), and alternate
communications (option 5).
359
Enable Option
1
Enable Option
1, 5
Enable Option 1,
2, 5
Options to turn on/off
tamper/restore for telephone
1 (option 1), telephone 2
(option 2), and alternate
communications (option 5).