17
Generic Keyswitch Programming
Keyswitch state programming examples for Ademco, Digital Security Controls, and GE NetworX for Keyswitch and panel
state program output operations are given below.
Most alarm panel manufacturers will have the capability to configure a zone as a keyswitch and generally have at least
one on-board programmable output that can be configured to activate on a number of different control state conditions.
Reference the alarm panel installation manual for details on your specific installation.
Ademco/Honeywell Vista (General Concept)
• 56 program zone as type 77
80 Menu LED Outs
• Program 17 and 18 zone type 78 and 79
DSC PowerSeries (General Concept)
• Program zone as ‘22’ PGM Output ‘6’
DSC Alexor (General Concept)
• Wiring: Y/Tx -> I/01 Terminal 13 -> I/02
• 6.2k ohms resistor from + positive -> Y/Tx
Programming:
• Section 009 - ‘05’/’22’
• Section 013 - Enable 2 & Disable 1
• Section 134 - Enable 14 (Press 9, then 6) This makes it normally closed.
• Section 501 - Enable 3
GE NetworX (General Concept)
• Location 25 Program zone as ‘11’ LED Status
• Location 47 Segment 1: Enter 21
• Location 47 Segment 2: Enter 0