Designation: AIR CONDITIONER FOR ELECTRICAL ENCLOSURE

 

Page 17/20

 

UMA-CDZ-IP-ACIRM100-00

 

WARRANTY 

 

WE 

IP ENCLOSURES 

 

 

 

 

guarantees that the product is free from any quality defects. 

The product is guaranteed for a period of 12 months from the date of delivery, provided it 
operates under the following conditions: 

1.  value of power supply indicated in the data plate is completely respected; 
2.  requirements specified on user’s manual are completely respected; 
3.  cabinet temperature is not higher or lower than its rated temperature; 
4.  ambient temperature is not higher or lower than its rated temperature; 
5.  the product is mounted on cabinets with a minimum IP54 protection level; 
6.  the product is mounted on cabinets that not requiring higher cooling power than 

expected; 

7.  the product is clearly identifiable by serial number. 

 
The warranty does not apply if : 

1.  the cooling circuit has been modified about type and quantity of refrigerant or 

composition; 

2.  the unit operates in acid or corrosive ambient; 
3.  the unit has been modified without IP ENCLOSURES consent. 

 

This warranty shall become null as soon as the product is altered or modified in its 
structure or in circuits. 
The terms of this warranty (commencement and termination dates) are not modified by 
any repair or replacement of products. 
For every part that results defective during the period of this warranty, IP ENCLOSURES 
shall repair or replace it. Any others charges arising from removal, handling and 
installation of the products shall not be refunded by IP ENCLOSURES. 
Like is specified on user’s manual, installation, handling, the correct earthing in 
accordance with all current standards are under the responsibility of costumer. 
In the event of any damage caused by a defective product shall apply the EEC85.374 
standard. 
The malfunction must be communicated in writing to IP ENCLOSURES. 
Warranty is void if the costumer is not in good standing with the payments 

 
 
 

 
 
 
 

 
 
 

Summary of Contents for IP-ACIRM100

Page 1: ...00 00 USER S MANUAL PART 2 ROOF MOUNT AIR CONDITIONER FOR ELECTRICAL ENCLOSURE INDOOR APPLICATION IP ACIRM100 Document UMA CDZ IP ACIRM100 00 Date Name Description Original user s manual for air condi...

Page 2: ...closure there must not be components that could affect the proper ventilation Provide a proper fixing of the electrical enclosure to the floor to prevent accidental tipping due to the supplementary we...

Page 3: ...ES Unit Power supply V ph Hz 230 1 50 60 Cooling capacity EN14511 A35 A35 W 1000 1060 A35 A50 W 760 790 Absorbed electric power EN14511 A35 A35 W 780 810 A35 A50 W 890 930 Rated current A 5 1 6 2 Moto...

Page 4: ...Electrical enclosure must be sized according to air conditioner dimensions and weight Electrical enclosure must have at least IP54 protection degree Internal and external components of electrical encl...

Page 5: ...hole on the enclosure as is shown in the drilling template VIEW FROM EXTERNAL OF ELECTRICAL ENCLOSURE Deburr all sharp edges to avoid accidental injuries 2 Apply the gasket included in fixing kit on t...

Page 6: ...ipes in order to ensure proper drainage in case of occlusion of a drain pipe Air conditioner produces condensate because the moist air inside of the enclosure meets cold heat exchanger evaporator and...

Page 7: ...Designation AIR CONDITIONER FOR ELECTRICAL ENCLOSURE Page 7 20 UMA CDZ IP ACIRM100 00 3 ELECTRICAL CONNECTION 3 1 WIRING DIAGRAM...

Page 8: ...andard Before the installation make sure that the cabinet is disconnected from the electrical supply Wire male plug included with an adequate cable as is shown by following picture Cable section must...

Page 9: ...larm output is activated according to alarm parameters for example in case of enclosure temperature higher than ALU value digital input not activated See PARAMETERS at 4 2 DIGITAL THERMOSTAT INSTRUCTI...

Page 10: ...lled only on the roof of electrical enclosure After finishing assembly of the conditioner wait approx 30 min before starting it the oil must collect in the compressor to ensure lubrication and cooling...

Page 11: ...ions for parameter changing To display target set point in programming mode it selects a parameter or confirm an operation DEF To start a manual defrost To see the max stored temperature in programmin...

Page 12: ...SET key or wait for 5 seconds to display the probe value again 4 2 5 HOW TO CHANGE THE SETPOINT 1 Push the SET key for more than 2 seconds to change the Set point value 2 The value of the set point w...

Page 13: ...defrost cycles 0 120h Determines the time interval between the beginning of two defrost cycles MdF Maximum length for defrost 0 255min 0 no defrost When P2P n not evaporator probe timed defrost it set...

Page 14: ...as the external digital input is disabled again With the door open the high and low temperature alarms are disabled Digital inputs polarity The digital input polarity depends on the i1P parameter i1P...

Page 15: ...Ht heating cL Pr1 rES Resolution in integer dE dec point dE Pr1 IdF Interval between defrost cycles 1 120 hours 8 Pr1 MdF Maximum length for defrost 0 255 min 0 Pr1 ALU MAXIMUM temperature alarm Set...

Page 16: ...ESCRIPTION CODE 1 Evaporator fan VCENT190D230V 2 Compressor COMPRSC12G 3 Condenser fan VCENT220D230U C1 Evaporator fan capacitor CON2UFS2M8F C3 Condenser fan capacitor CON2UFS2M8F 4 Regulating thermos...

Page 17: ...oling circuit has been modified about type and quantity of refrigerant or composition 2 the unit operates in acid or corrosive ambient 3 the unit has been modified without IP ENCLOSURES consent This w...

Page 18: ...UE LOW VOLTAGE DIRECTIVE 26 February 2014 2014 30 UE EMC DIRECTIVE 26 February 2014 2011 65 UE ROHS DIRECTIVE 8 June 2011 STANDARDS APPLIED TO MEET THE PRINCIPAL ELEMENTS OF THE DIRECTIVE EN 60335 2 4...

Page 19: ...Designation AIR CONDITIONER FOR ELECTRICAL ENCLOSURE Page 19 20 UMA CDZ IP ACIRM100 00 SAA CERTIFICATE...

Page 20: ...Designation AIR CONDITIONER FOR ELECTRICAL ENCLOSURE Page 20 20 UMA CDZ IP ACIRM100 00 NOTES...

Reviews: