Page 4
“Written records of testing shall be kept by the owner for inspection by the authority having jurisdiction.”
SERVICING SHOULD BE PERFORMED BY QUALIFIED PERSONNEL.
Consult Customer Service or visit www.iotaengineering.com for current warranty information.
TESTING & MAINTENANCE
WIRING DIAGRAM
Maintenance
When performing maintenance the
ILB-LP-CP-HE-SD-HV
must be completely powered down by removing AC power and
performing one of the following steps:
1) Pressing and holding the TSPL button for approximately five seconds until the LED Module shuts off. This function can only
be performed during the first 30 seconds of Emergency Mode.
2) Unplugging the TSPL in Emergency Mode.
Automatic Testing
The
ILB-LP-CP-HE-SD-HV
is designed to automatically test the emergency function for five minutes each month, and 90
minutes every 12 months.
Self-testing works in conjunction with the TSPL assembly. Any detected failures will be indicated by flashing of the bi-color
LED. See Table A below for diagnosis:
Manual Testing
Manual testing of the
ILB-LP-CP-HE-SD-HV
can be performed by pressing and releasing the TSPL test button.
Table A:
TSPL Diagnostic Codes
CONDITION
STATUS INDICATION
STEADY GREEN OR STEADY RED
NORMAL MODE
FLASHING GREEN
SELF-TESTING
OFF
EMERGENCY MODE
FLASHING RED/GREEN
INSUFFICIENT CHARGE
1 RED FLASH
BATTERY PACK FAILURE
2 RED FLASHES
EMERGENCY LAMP FAILURE
3 RED FLASHES
FIXTURE DIAGNOSTIC FAILURE DETECTED
4 RED FLASHES
TEMPERATURE OUT OF RANGE
ILB-LP WITH TSPL TEST ACCESSORY
AC (NORMAL)
DRIVER
IOTA ILB-LP
EMERGENCY DRIVER
LED
LOAD
WHITE
WHITE
WHT/RED
NEUTRAL
UNSWITCHED
24/7 POWER
BLACK (120 TO 277V, 50/60HZ)
AC INPUT (120 TO 277V)
SWITCHED OR
UNSWITCHED
HOT
TSPL
TEST ACCESSORY
RED (+)
BLUE (-)
VIOLET/WHITE (+)
LED INPUT(-)
LED INPUT (+)
LED OUTPUT (+)
LED OUTPUT (-)
ATTENTION:
DO NOT CONNECT THE TSPL CONNECTOR UNTIL
INSTALLATION IS COMPLETE AND AC POWER IS SUPPLIED.
CONNECT TSPL AFTER INSTALLATION IS COMPLETE AND
AC POWER IS SUPPLIED
YELLOW
BROWN
GROUND
LEDCODE (+)
LEDCODE (-)
Refer to the diagram below for the appropriate wiring of the LED load and driver. Install in accordance with the National Electrical
Code and local regulations. For additional wiring diagrams consult Customer Service.
!
Cap LEDCODE wires
if unused