background image

The DLS-X features an accessory port on the fan end of the unit for installing an IQ4-X Charge Control Module for automatic 
four-stage charging. 

Installing the IQ4-X Charge Control Module gives the user the benefit of automatic Bulk, Absorption, and Float stage charg-
ing. This increases the charging capacity of the IOTA charger, decreases charge times and insures proper and safe battery 
charging without over-charging. The green LED on the module will indicate which charging phase the IOTA charger is currently 
in. When the unit is first activated, the LED will flash as it reads the number of cells in the battery. The unit will then initiate the 
four-stage charging algorithms. The LED indicator will flash according to the active charging stage of the unit. Use the LED 
CODE TABLE for reference when checking the LED. 

To install an IQ4-X module into the charger, remove the fastening screw on the top of the port faceplate and detach the face-
plate. Plug the control module into the port and secure in place using the original fastening screw. NOTE: the port faceplate 
and IQ4-X control module are similar in appearance. You can recognize the IQ4-X Charge Control Module by the presence 
of the LED indicator on the face.

ACCESSORY PORT AND IQ4-X CHARGE CONTROL MODULE

*Actual component locations may vary depending on model.

ILLUSTRATION 1 - DLS-X CONNECTIONS*

ILLUSTRATION 2 - AC INPUT PLUG

ILLUSTRATION 3 - IQ4-X MODULE INSTALLATION

NEMA 5-20P PLUG

FOR 20A RECEPTACLE

NEMA 5-30P PLUG

FOR 30A RECEPTACLE

NEMA 5-15P PLUG

FOR 15A RECEPTACLE

SDC1-120-12-15, SDC1-120-12-30, 
SDC1-120-12-45, SDC1-120-12-55

SDC1-120-12-75

SDC1-120-12-90

Torque the connections to the proper rating  
according to the wire manufacturer’s  
specifications.

AMPLIFE
CHARGE CONTROL 
MODULE

ACCESSORY PORT
ON END OF SDC1

NEMA 5-20P PLUG

FOR 20A RECEPTACLE

NEMA 5-30P PLUG

FOR 30A RECEPTACLE

NEMA 5-15P PLUG

FOR 15A RECEPTACLE

SDC1-120-12-15, SDC1-120-12-30, 
SDC1-120-12-45, SDC1-120-12-55

SDC1-120-12-75

SDC1-120-12-90

NEMA 5-20P PLUG

FOR 20A RECEPTACLE

NEMA 5-30P PLUG

FOR 30A RECEPTACLE

NEMA 5-15P PLUG

FOR 15A RECEPTACLE

SDC1-120-12-15, SDC1-120-12-30, 
SDC1-120-12-45, SDC1-120-12-55

SDC1-120-12-75

SDC1-120-12-90

DLS-90-X

NEMA 5-20P PLUG

FOR 20A RECEPTACLE

NEMA 5-30P PLUG

FOR 30A RECEPTACLE

NEMA 5-15P PLUG

FOR 15A RECEPTACLE

SDC1-120-12-15, SDC1-120-12-30, 
SDC1-120-12-45, SDC1-120-12-55

SDC1-120-12-75

SDC1-120-12-90

DLS-75-X

DLS-15-X, DLS-30-X, DLS-45-X, DLS-55-X,

IQ4-X

Accessory Port
on DLS-X

Reviews: