background image

Level 2 - 160 Home Charging Station

Cat. No. EVB22 (Plug-in), EVB26 (Hard-wire) - 16A @ 240VAC, 60Hz

Installation Instructions

WARNINGS AND CAUTIONS:

• 

EVB26 hard-wire installation and service must be performed by an electrician.

•  If the information in this instruction sheet is not followed exactly, shock or fire may result causing property damage, personal injury or death.
•  Connect to an individual branch circuit, 240VAC, 60Hz.
• 

IMPORTANT: Save these instructions for local electrical inspector’s use and future reference.

PK-93742-10-00-0A-X2

Thank you for purchasing the Level 2 160 Home Charging Station. This installation 

sheet includes the latest information at the time of printing. Leviton reserves the right to 

make changes to this product without further notice. Changes or modifications to this 

product by other than an authorized service provider could void the product warranty. 

If you have questions about the use of this product, contact your Customer Service 

Representative. Refer to the Customer Support section located in these instructions.
Important Notes to the Installer:
• 

Read all instructions contained in these installation instructions before installing 

hard-wired version of the Charging Station.

• 

The installer is responsible for verifying that the wall structure/surface will safely 

support a total load of 200 lbs.

• 

Observe all governing codes and ordinances.

• 

Be sure to leave these instructions with the consumer.

Important Notes to the Consumer:
• 

Keep these instructions with your User Guide for future reference.

• 

Ensure your Charging Station is installed properly by an electrician or service 

technician.

INTRODUCTION

Gather the required tools and parts before starting installation. Be sure to follow 

manufacturer’s instructions for use of any tools or parts used for this installation.
Tools:

• 

Drill with 3/16" bit  • 

Stud finder 

•  Level

• 

Scratch awl 

• 

#2 and #3 Phillips screwdriver 

•  Utility knife

• 

Measuring tape 

• 

Wire cutters/strippers 

•  Keyhole saw

EVB26 Hard-Wire Charging Station (includes):

• 

Single stud Mounting Bracket 

•  Mounting template 

•  Ferrite (1)

• 

#14 wood mounting screws (2) 

•  #8-32 Set screw (1) 

•  Key (1) 

(stud mount only)   

 

•  Warranty Void label (1)

Additional Parts (not included):

• 

Copper electrical cable (appropriate for circuit) 

•  Conduit

• 

Circuit breaker (appropriate for circuit)   

•  Strain relief (if applicable)

For Metal Stud Applications:

• 

Wall anchors capable of supporting a maximum allowable load of 200 lbs.

For Solid Wall Applications:

• 

Wall anchors capable of supporting a maximum allowable load of 200 lbs.

• 

Appropriate conduit and applicable mounting hardware.

MOUNTING LOCATION

The Charging Station should be located in close proximity to the electric vehicle’s 

parking location. The Charging Station must connect to the electric vehicle via a  

Charge Connector and Charge Connector Cord. 

NOTE: The path from the Charging 

Station to the electric vehicle should be free from obstacles, and be within the range 

of the Charge Connector Cord (18 feet standard length).
The recommended mounting height of the Charging Station is not to exceed 48 

inches, but not less than 42 inches. This provides convenient access and operation of 

the Charging Station, and meets ADA requirements for access.
NOTE: The Charging Station enclosure exceeds the size of the mounting bracket. 

The area surrounding the Charging Station enclosure should be free from obstruction  

(see appropriate mounting template for required clearance limits).

MOUNTING BRACKET INSTALLATION

Select a location that is suitable for mounting the Charging Station based on the 

criteria presented in the MOUNTING LOCATION section. 

NOTE: The Mounting 

Bracket may need to be located from an existing wall box if applicable (refer to 

Mounting Template).
The Mounting Bracket can be installed on both stud wall and solid wall construction. 

For stud walls, it can be mounted to bare studs or walls with drywall.
For metal stud or solid wall applications, you will need to procure wall anchors for 

the Mounting Bracket, capable of supporting a maximum allowable load of 200 lbs. 

For solid wall applications you will also need to procure appropriate conduit and 

appropriate wall anchors.

NOTE: The EVB22 Charging Station requires a Pre-Wire Kit installation prior to 

mounting. Refer to Pre-Wire Kit instructions first if a mounting location has not been 

established.
1.  Locate the slot above the thumb screw. Locate the four Mounting Buttons on the 

back of the Charging Station 

(see Figure 1).

2.  Align the slot with the guide pin, and the four Mounting Buttons with the four key 

holes on the Mounting Bracket.

3.  Once aligned, gently press the Charging Station onto the Mounting Bracket.
4.  Allow the Charging Station to slowly slide down into place. 
5.  Tighten the thumb screw to secure Charging Station to Mounting Bracket.
Proceed to POWER CHARGING STATION section.

EVB22 INSTALLATION (Plug-in)

EVB26 INSTALLATION (Hard-Wire)

TO INSTALL: 
1.  Locate a wall stud in the area in which the Charging Station will be installed.
2.  Measure 48" up from the floor and place a mark horizontally centered on the stud 

that will be used for the Mounting Bracket. 

3.  Position and affix the Mounting Template on the wall, aligning the positioning 

marks of the Mounting Template with the mark(s) on the wall. Ensure the 

Mounting Template is level before proceeding 

(see Figure 2).

4.  Mark the Mounting Bracket hole locations.
5.  Remove the Mounting Template. For wood studs, drill two 3/16" diameter pilot 

holes, 2-1/2" deep, as indicated for the Mounting Bracket. For metal studs, follow 

manufacturer’s instructions for wall anchor installation.

6.  Secure the Mounting Bracket to the stud/wall using the two #14 x 2-1/2"L 

wood screws provided. Turn the "top" screw into the pilot hole and drive in 

until approximately 1/2" length remains. Hook the Mounting Bracket onto the 

screw using the keyhole slot. Secure in place by installing remaining screw and 

tightening first screw.

Mounting

bracket

Mounting

screws

Pilot holes

for mounting

screws

Mounting

template

Center line

for wall stud

Wall stud

Drywall

Stud Wall Installation

Figure 2

48"

Elect

ric Vehicl

e Charger 

Level

 2 - Install

ation 

Temp

late

Scale

: 1 to

 1

Ref. C

at. No

.: EVK

02

Part N

o. DG-

001-E

VK02

-20A-

X1

© 201

0 Lev

iton Mfg

. Co.,

 Inc.

Mounting

buttons

Mounting

bracket

(mounted
to wall) 

Guide pin

Thumb

screw

Charging Station Mounting

Figure 1

Rear view

START

STOP

Reviews: