background image

INSTALLATION GUIDELINES

mOUNTING LOCATION

The IOTA Power Converter/Battery Charger can be mounted 
in  any  position  within  an  enclosed  or  interior  compartment. 
Provide sufficient air space to allow unrestricted airflow in and 
around the unit. Provide at least 4

 around the fan of the DLS 

to allow for proper air intake.

DO NOT

 mount the unit in a zero clearance compartment. 

DO  NOT 

mount  the  DLS  in  the  same  compartment  with 

flammable items such as gasoline or batteries. There are no 
components within the DLS unit that, during normal operation, 
produce arcs or sparks. However, all electronic devices have 
some  potential  for  generating  sparks  in  the  event  of  failure 
which can result in explosion or fire.

DO NOT

 mount the DLS in an area that has the potential of 

dust, debris, or other foreign materials to enter in through the 
DLS vents. 

DO NOT

 place the DLS directly above the battery; the gases 

from the battery can corrode and damage the DLS.  

bATTERY CONNECTION

Before you connect the DLS to the battery, make sure that the 
AC power cord is NOT plugged into an electrical outlet.
Disconnect the positive side of the battery before installation. 
Connect the positive (red) and negative (black) terminal lugs to 
battery or load (

lugs require a #2 square drive

). Always use the 

proper size wire based on the amperage of the converter and 
the battery. When connecting to a battery, a breaker should be 
installed within 18

 

of the battery, connecting the battery posi-

tive to the line side of the breaker, and the IOTA unit to the load 
side. Connect “Chassis Bonding Lug” on the IOTA unit to vehicle 
chassis or other grounding source. Refer to Illustration 1.

120 VOLT A.C. INPUT

 

Plug the unit A.C. input cord into an appropriate 120-volt 3-wire 
grounded source. Refer to Illustration 2 for specifications of the 
cord provided with your DLS unit. See the Technical Specifica-
tions Chart on page 4 for maximum current draw and required 
input voltages.
DO  NOT  USE  EXTENSION  CORDS  -  Using  an  improper 
extension cord could result in a risk of fire and electric shock, 
and may result in property damage, personal injury or death.
DO NOT OPERATE THE DLS WITH A DAMAGED CORD OR 
PLUG. Have the cord or plug replaced immediately by qualified 
service personnel.

REVERSE POLARITY FUSES

The IOTA Battery Charger/Power Supply is protected against 
reverse polarity on the DC output. If a battery or the unit is 
hooked up incorrectly, the fuses will blow and can be easily 
replaced. Always use the same size and style fuse that came 
with the converter. To change the fuses, use a screwdriver 
to loosen the screws and remove the fuses. Always replace 
the fuses with the same type and rating. After inserting the 
new  fuses,  tighten  the  screws  firmly.  Apply  5  inch-pound  
maximum  torque.  DO  NOT  OVERTIGHTEN. 

Note:  some 

DLS models require only one fuse. For these units, a small 
fiberglass spacer may be used in the empty fuse slot to aid 
with tightening.

IOTA DLS Series Power Converter/Battery Chargers con-
vert 120 volts nominal A.C. to 13.6 volts D.C. As a power 
supply, its tightly controlled regulation allows the user to 
operate any 12 volt nominal D.C. load up to the converter’s 
rated output current. As a battery charger, the converter will 
maintain the battery, delivering its full-rated current when 
the battery capacity falls sufficiently low. The voltage is set 
to deliver its maximum current for the necessary period of 
time that minimizes undue stress to the battery caused by 
heating of its cells. This helps to ensure the longest pos-
sible life of the battery. Over time, as the battery nears its 
full capacity, the converter will float-charge the battery to 
prevent self-discharge of its cells.  

PROTECTION FEATURES

The  IOTA  Power  Converters/Battery  Chargers  are  de-
signed  with  high  quality  components  to  help  ensure 
years of continuous use. The unit is protected by multiple 
protection features for a long, trouble-free life.

1) 

Reverse Battery Polarity Protection.

 2) 

Brown-Out In-

put Protection.

 3) 

Over-Current Protection

 - cycle by cycle 

peak limiting as well as rated current limiting to maximize 
the life of the converter. 4) 

Over-Temperature Protection. 

In addition, it is designed with a unique “proportional” fan 
control circuit. Fan speed is directly proportional to the 
converter’s internal ambient temperature. This enables 
the fan to turn on and off very slowly, minimizing unwanted 
fan-starting noise. 

The  IOTA  Power  Converters/Battery  Chargers  are  war-
ranted from defects in materials or workmanship for two 
years from date of retail purchase, and limits the remedies 
to  repair  or  replacement. This  warranty  is  valid  only  in 
the  continental  United  States  and  Canada.  For  com-
plete warranty details, contact Customer Service or visit  
www.iotaengineering.com.

WARRANTY

PRODUCT DESCRIPTION

Summary of Contents for DLS-15

Page 1: ...designed for indoor use Do not use outdoors DO NOT expose the DLS unit to rain snow or other inclement weather Do not mount the DLS in a zero clearance compartment or in compartments with flammable items such as gasoline or batteries Do not mount the DLS in an area with the potential of dust debris or other foreign materials entering the vents of the DLS Use of an attachment or device with the DLS...

Page 2: ...r Power Supply is protected against reverse polarity on the DC output If a battery or the unit is hooked up incorrectly the fuses will blow and can be easily replaced Always use the same size and style fuse that came with the converter To change the fuses use a screwdriver to loosen the screws and remove the fuses Always replace the fuses with the same type and rating After inserting the new fuses...

Page 3: ...decreases charge times and insures proper and safe battery charging without over charging The green LED on the fan end of the unit will indicate which charging phase the IOTA unit is currently in When the unit is first activated the LED will flash as it reads the number of cells in the battery The unit will then proceed directly to the Bulk charging or Float charging phase depending on the charge ...

Page 4: ... 400 Watts 50 mV rms 108 132 AC 47 63 7 3 Amps 80 30 Amps Yes 100 100 mV rms 1 PROPORTIONAL YES 0 40 C 20 to 80 C 1700 1700 500 9 7 x 6 7 x 3 4 5 0 lbs 13 6V DC or 7 45 Amps 13 4V DC 600 Watts 50 mV rms 108 132 AC 47 63 11 Amps 80 30 Amps Yes 100 100 mV rms 1 5 PROPORTIONAL YES 0 40 C 20 to 80 C 1700 1700 500 9 7 x 6 7 x 3 4 5 0 lbs 13 6V DC or 7 55 Amps 13 4V DC 750 Watts 50 mV rms 108 132 AC 47 ...

Page 5: ...r les directives ci dessous Le DLS est conçu pour une utilisation intérieure Ne pas utiliser à l extérieur NE PAS exposer l unité DLS à la pluie neige ou autre intempérie Ne pas monter le DLS dans un compartiment à tolérance zéro ou dans des compartiments avec des objets inflammables tels que de l essence ou des batteries Ne pas monter le DLS dans une zone où de la poussière des débris ou autres m...

Reviews: