OUTER SURFACES CLEANING
During the unit use, some impurities may also be caught on
the outer surface of the air purifier, especially on the ribbed
openings. Use the enclosed pencil or a damp cloth.
Before you start cleaning, ensure that the unit is unplugged
from the electrical network. If you use a damp cloth, you must
prevent any water leaking into the unit, which could damage
the unit functions or cause the user’s injury. Before you put
the purifier into operation, let it dry for at least 24 hours.
Clean the unit as needed.
PROBLEMS SOLVING
PROBLEM
CAUSE
SOLUTION
Indication of setting does not light up
The unit is not plugged in the electrical socket
Check the plug whether it is connected to the
electrical network
The main switch was not pressed
Press the main switch
Red warning light indicating the unit
pollution or defect is on.
Too much collected dust
Switch the unit off and disconnect it
from the electric network
Clean it according to the section Cleaning and
Maintenance (stainless wires)
The stainless filter has been moved or remo-
ved suddenly during the unit operation
Remove and reinsert the stainless filter and press
the main switch to restart the unit
The red indicator may light up when
the unit needs a restart only
To restart the unit, press the main switch
The red indicator is on if the ionizing wire
is broken, or if there is a foreign object in
the unit
Do not put the unit into operation and contact our
service centre (see section Contacts)
The unit makes excessive noise
Too much collected dust
Switch the unit off and disconnect it
from the electric network
Clean it according to the section Cleaning and
Maintenance (stainless wires)
Inner parts of the unit are damp
Dry the unit thoroughly
The control diode does not light up
The stainless filter has not been inserted into
the unit properly
Ensure that the stainless filter is inserted into the
unit properly and end-to-end
The mechanism for the ionizing wires clea-
ning has not been inserted properly
Ensure that the mechanism for the ionizing wires
cleaning is inserted into the unit properly and
end-to-end