background image

3

SAFETY MEASURES

For safety reasons, please read these Instructions for Use attentively before putting the unit into ope-

ration. Those who do not acquaint themselves with these Instructions for Use should not put the unit 

into operation. You must bear in mind that Ionic-CARE is a high-voltage device and, like in electrical 

hot-air heaters, some of its parts are open (to ensure ventilation) and conductive objects can be inserted 

in them. To allow proper ventilation, the vents may not be covered, excessive dust deposition inside 

the unit must be prevented, and the unit may not be placed near flammable objects. 

•  Important information: The safety instructions given in these Instructions for Use should always be followed when 

using this unit or any other electrical appliance. By reading of and complying with the below given warnings, you will 

reduce the risk of an electrical accident or fire.

•  Use the unit only in the way described in these Instructions for Use.
•  In the interests of lowering the risk of an electrical accident, do not try to maintain the unit in any other way than 

described in section Cleaning and Maintenance.

•  Do not use the unit outdoors.
•  Do not use the unit in damp environment (e.g. in a bathroom); relative humidity should not exceed 60 %.
•  Do not use the unit in the vicinity of fireplaces or in areas where flammable materials, flammable dust or vapours can 

occur. The air is ionized by microscopic electrical sparking (corona discharge) which can set flammable materials easily 

(just as an electric drill, blender, or vacuum cleaner).

•  Ensure that the unit works with correct voltage and power rate  220–240 V / 50 Hz.
•  To reduce the risk of an electrical accident, the unit has a plug with earthing. The plug has a third earthing connector. 

The plug can be used only in combination with a socket provided with earthing. In case of an atypical socket, please 

contact the appropriate service centre and ask them to install a correct socket. Do not adjust the plug in any way! 

•  Before you disconnect the plug from the socket, always switch the unit off.
•  Before you clean the stainless filter, always switch the unit off and unplug it from the socket.
•  If the unit is not to be used for a longer time, disconnect it from the electric network.
•  Never touch the inner parts of the unit like electrodes, ionizing wires etc. by any object.
•  Any attempt to disassemble the unit will result in loss of the warranty and can cause severe injury to the user or severe 

damage of the unit.

•  Do not place the supply cable of the unit near heat sources or on sharp edges.
•  Never put the unit into operation if the supply cable or the plug are or appear damaged. The damaged supply cable may 

be replaced only by an authorized service.

•  When disconnecting the unit from the electric network, grip the plug and pull it out of the socket. Never pull the 

supply cable.

•  When operating the unit, avoid putting fingers, parts of the body, loose clothes, jewels, and other objects in the unit 

openings.

•  Never touch the unit or its plug if your hands are wet.
•  The air purifier is an electric device. If it is used in presence of children, they must be supervised by an adult.
•  Do not touch the stainless filter until you discharge the residual voltage by the stainless filter contact with an electrically 

earthed object like metal water piping, water tap, or a radiator.

•  The stainless filter should be inspected and cleaned regularly to prevent excessive dust collection, which could cause 

a short-circuit or fire.

Summary of Contents for TRITON X6

Page 1: ...INSTRUCTIONS FOR USE COMBINATION AIR PURIFIER AND IONISER UNIT IONIC CARE TRITON X6 ...

Page 2: ...er use CONTENTS Technical parameters 2 Safety measures 3 Important precautions 4 Special precautions 5 Preparing for the unit start 5 Setting 6 Operation 6 Cleaning and maintenance 7 Stainless filter insertion and removal 7 Stainless filter cleaning 8 Ionizing wires cleaning 8 Outer surfaces cleaning 9 Problems solving 9 FAQ 10 Warranties 11 Contacts 11 TECHNICAL PARAMETERS Power input max 12W Pow...

Page 3: ...duce the risk of an electrical accident the unit has a plug with earthing The plug has a third earthing connector The plug can be used only in combination with a socket provided with earthing In case of an atypical socket please contact the appropriate service centre and ask them to install a correct socket Do not adjust the plug in any way Before you disconnect the plug from the socket always swi...

Page 4: ...arning ensure that the wick length does not exceed 6 mm to reduce the smoke production Figure A shows the stainless filter which is a key part of the air purifier and ioniser If the unit is run ning the stainless filter catches dust pollutants allergens and irritants and neutralizes smells The air purifier is designed to make no noise and requires very little time and effort for maintenance If you...

Page 5: ...n other electrical appliances peak voltage in the electrical network caused e g by a lightning can damage the unit and even cause fire PREPARING FOR THE UNIT START The unit can be in operation 24 hours daily at the temperature of 10 40oC and humidity 15 60 Place the unit on hard flat surface at least 0 5 m far from objects that could prevent easy air drawing and circulation e g flying curtains and...

Page 6: ... is most economical and best for small rooms The mode delivers maximum power and is good for great rooms Note Iftheunitispluggedinthesocket itconsumeselectricalenergyofapproximately0 080kWh day i e aboutCZK15 month evenifitis switchedoff Incaseofyourlong termabsence theunitunpluggingfromtheelectricnetworkisrecommended OPERATION Set the air inlet in a way described in section Preparing for the Unit...

Page 7: ...rifier exposure to such environment see section Important Precautions Attention Do not forget to clean the unit every 4 7 days and at any time the red indicator lights up pollution unit error Noisy operation of the unit audible hissing sound indicates that the purifier needs complete cleaning Before you start the unit cleaning ensure that you have read all important precautions and cleaning proced...

Page 8: ...ng the filter may be completely dry within 2 to 3 hours Always let the stainless filter dry thoroughly in vertical position before you reinsert it in the unit If you used some detergent and water to clean the stainless filter let it dry for 24 hours at least and before you reinsert it in the unit ensure that it is dried thoroughly Before you reinsert the stainless filter in the unit check undamage...

Page 9: ... section Cleaning and Maintenance stainless filter wires The stainless filter has been moved or remo ved suddenly during the unit operation Remove and reinsert the stainless filter and press the main switch to restart the unit The red indicator may light up when the unit needs a restart only To restart the unit press the main switch The red indicator is on if the ionizing wire is broken or if ther...

Page 10: ... e g on a cabinet or table Can I use the ioniser near an electronic nanny or cardiac pacemaker Electronic nannies work with higher frequencies while the cardiac pacemakers with lower frequencies than the unit They cannot therefore interfere with each other Can I disassembly the unit and clean the inner part of it No intervention in the unit is recommended because even after it is disconnected from...

Page 11: ... o Veverkova 1343 1 500 02 Hradec Králové Tel 498 500 604 Fax 498 500 605 E mail info hogner cz www hogner cz ID 27503542 TAX ID CZ27503542 Technical and complaints department HÖGNER s r o Veverkova 1343 1 500 02 Hradec Králové Tel 498 500 604 Fax 498 500 605 E mail reklamace hogner cz www ionic care cz Feeforthebackwithdrawalanduseofthematerialhasbeenpaidinrelationtothepacksofthisproduct Feeforth...

Page 12: ...www ionic care cz Low consumption 12 W Maximum room area 75 m2 Quiet operation 8 dB Dustproof efficiency 96 Non stop operation 24 7 Life long filter ...

Reviews: