WARRANTIES

The valid warranty period is 24 months and starts on the day of the goods delivery (receipt).

The warranty applies to defects of material or production with the below given exceptions. It is condi-

tioned by completeness of the claimed goods and submittal of a document proving the purchase and 

the warranty certificate. The conditions relating the business, complaints, and warranties specified in 

the warranty certificate must also be complied with. The warranty does not apply to defects caused by 

improper use, to damage caused due to insufficient or erroneous cleaning and maintenance of the unit, 

and to defects caused by mechanical damage of the unit (e.g. the unit fall). For full warranty conditions 

and periods, see the unit warranty certificate.

CONTACTS

Seller and service:

HÖGNER, s.r.o.

Veverkova 1343/1

500 02  Hradec Králové

Tel.: 498 500 604

Fax: 498 500 605

E-mail: [email protected]

www.hogner.cz

ID: 27503542

TAX ID: CZ27503542

Technical and complaints department:

HÖGNER, s.r.o.

Veverkova 1343/1

500 02  Hradec Králové

Tel.: 498 500 604

Fax: 498 500 605

E-mail: [email protected]

www.ionic-care.cz

Fee for the back withdrawal and use of the material has been paid in relation to the packs of this product. Fee for the back 

withdrawal, processing and ecologically friendly removal of electrical appliances has been paid in relation to the product.

The symbol shown on the product or in the accompanying documents means that the used electrical or electronic products 

may not be liquidated together with municipal waste. To ensure proper liquidation of the product, deliver it at special 

collecting sites where they will be accepted free of charge. You can get more detailed information at the appropriate 

municipal office, your seller or supplier. You can find the updated list of back withdrawal sites of electrical appliances 

at e.g. 

www.elektrowin.cz

Summary of Contents for TRITON X6

Page 1: ...INSTRUCTIONS FOR USE COMBINATION AIR PURIFIER AND IONISER UNIT IONIC CARE TRITON X6 ...

Page 2: ...er use CONTENTS Technical parameters 2 Safety measures 3 Important precautions 4 Special precautions 5 Preparing for the unit start 5 Setting 6 Operation 6 Cleaning and maintenance 7 Stainless filter insertion and removal 7 Stainless filter cleaning 8 Ionizing wires cleaning 8 Outer surfaces cleaning 9 Problems solving 9 FAQ 10 Warranties 11 Contacts 11 TECHNICAL PARAMETERS Power input max 12W Pow...

Page 3: ...duce the risk of an electrical accident the unit has a plug with earthing The plug has a third earthing connector The plug can be used only in combination with a socket provided with earthing In case of an atypical socket please contact the appropriate service centre and ask them to install a correct socket Do not adjust the plug in any way Before you disconnect the plug from the socket always swi...

Page 4: ...arning ensure that the wick length does not exceed 6 mm to reduce the smoke production Figure A shows the stainless filter which is a key part of the air purifier and ioniser If the unit is run ning the stainless filter catches dust pollutants allergens and irritants and neutralizes smells The air purifier is designed to make no noise and requires very little time and effort for maintenance If you...

Page 5: ...n other electrical appliances peak voltage in the electrical network caused e g by a lightning can damage the unit and even cause fire PREPARING FOR THE UNIT START The unit can be in operation 24 hours daily at the temperature of 10 40oC and humidity 15 60 Place the unit on hard flat surface at least 0 5 m far from objects that could prevent easy air drawing and circulation e g flying curtains and...

Page 6: ... is most economical and best for small rooms The mode delivers maximum power and is good for great rooms Note Iftheunitispluggedinthesocket itconsumeselectricalenergyofapproximately0 080kWh day i e aboutCZK15 month evenifitis switchedoff Incaseofyourlong termabsence theunitunpluggingfromtheelectricnetworkisrecommended OPERATION Set the air inlet in a way described in section Preparing for the Unit...

Page 7: ...rifier exposure to such environment see section Important Precautions Attention Do not forget to clean the unit every 4 7 days and at any time the red indicator lights up pollution unit error Noisy operation of the unit audible hissing sound indicates that the purifier needs complete cleaning Before you start the unit cleaning ensure that you have read all important precautions and cleaning proced...

Page 8: ...ng the filter may be completely dry within 2 to 3 hours Always let the stainless filter dry thoroughly in vertical position before you reinsert it in the unit If you used some detergent and water to clean the stainless filter let it dry for 24 hours at least and before you reinsert it in the unit ensure that it is dried thoroughly Before you reinsert the stainless filter in the unit check undamage...

Page 9: ... section Cleaning and Maintenance stainless filter wires The stainless filter has been moved or remo ved suddenly during the unit operation Remove and reinsert the stainless filter and press the main switch to restart the unit The red indicator may light up when the unit needs a restart only To restart the unit press the main switch The red indicator is on if the ionizing wire is broken or if ther...

Page 10: ... e g on a cabinet or table Can I use the ioniser near an electronic nanny or cardiac pacemaker Electronic nannies work with higher frequencies while the cardiac pacemakers with lower frequencies than the unit They cannot therefore interfere with each other Can I disassembly the unit and clean the inner part of it No intervention in the unit is recommended because even after it is disconnected from...

Page 11: ... o Veverkova 1343 1 500 02 Hradec Králové Tel 498 500 604 Fax 498 500 605 E mail info hogner cz www hogner cz ID 27503542 TAX ID CZ27503542 Technical and complaints department HÖGNER s r o Veverkova 1343 1 500 02 Hradec Králové Tel 498 500 604 Fax 498 500 605 E mail reklamace hogner cz www ionic care cz Feeforthebackwithdrawalanduseofthematerialhasbeenpaidinrelationtothepacksofthisproduct Feeforth...

Page 12: ...www ionic care cz Low consumption 12 W Maximum room area 75 m2 Quiet operation 8 dB Dustproof efficiency 96 Non stop operation 24 7 Life long filter ...