background image

Summary of Contents for FGA-2000

Page 1: ......

Page 2: ...the Manual This manual introduces the operations of FGA 5000 product All figures displayed are for illustration purposes only Figures in this manual may not be exactly consistent with the actual prod...

Page 3: ...xample press OK Window names menu items data table and field names are inside square brackets For example pop up the New User window Multi level menus are separated by forwarding slashes For example F...

Page 4: ...USER ROLE 11 4 1 3 VERIFICATION MODE 12 4 1 4 ENROLLING A FINGERPRINT 12 4 1 5 ENROLLING A BADGE 12 4 1 6 ENROLLING A PASSWORD 13 MANAGING EXISTING USERS 13 4 2 1 EDIT USER 13 4 2 2 DELETE USER 13 DI...

Page 5: ...TING DOOR PROPERTIES 31 DEFINING TIME SCHEDULES 32 SETTING HOLIDAYS 33 CREATING ACCESS GROUPS 33 MULTI USER AUTHENTICATION 34 DURESS SETTINGS 35 11 USB MANAGER 35 DOWNLOAD 36 UPLOAD 36 DOWNLOAD OPTION...

Page 6: ...operation process make it popular Elaborately designed and finely processed it matches your slap up office perfectly Features Palm Fingerprint RFID Ready Elegant ergonomic design Easy installation Wi...

Page 7: ...se they press the collection window is usually very clumsy Recommended placement Verification Modes 2 2 1 Biometrics Fingerprint 1 N fingerprint verification The device compares the current fingerprin...

Page 8: ...ser chooses this mode unless poor recognition Enter User ID and press fingerprint there are two responses after verification Successfully verified and Failed to verify Note 1 The device prompts Invali...

Page 9: ...it returns to the initial interface 2 2 3 Access Card Card function is optional only products with a built in card module are equipped with card verification function Please contact our technical supp...

Page 10: ...red in the device Access Control Set access control options time schedule holidays access group combined verification group and duress options USB Manager Download and upload attendance data user data...

Page 11: ...e New User interface press M OK 4 1 2 Enter User Role Press to select User Role on the New User interface press M OK Note You can input an ID or use which is allotted by the device Super Admin A super...

Page 12: ...the New User interface press M OK There are several optional modes to set the verification way 1 Press numeric key corresponding to the fingerprint as you want then press M OK 2 Press your fingerprint...

Page 13: ...Existing Users Start the device enter into the Main Menu Enter into User Mgt All Users 4 2 1 Edit User All information can be modified except User ID 4 2 2 Delete User Press to select a user to edit a...

Page 14: ...ngle Line Enter into User Mgt Display Style 5 User Role Use to define roles to operate the device You can specify the available menus to operate for a role There are 3 roles Enter into User Role Press...

Page 15: ...ith PC each other via the parameters you set 2 Serial Comm The device can communicate with PC each other via the serial port parameters you set 3 PC Connection Set the password and device ID so that y...

Page 16: ...e dynamic IP addresses to clients by a server 7 Display in Status Bar Whether to display network status icons in the status bar 1 Serial port When serial port RS232 RS485 is used for communication of...

Page 17: ...o using The value no using means that the format with this bit number is not used The following table describes all the formats 1 Enable Domain Name When the domain name mode is enabled you access a w...

Page 18: ...is the even parity bit of the 2nd to 13th bits while the 26th bit is the odd parity bit of the 14th to 25th bits The 2nd to 9th bits are the site code while the 10th to 25th bits are the card number W...

Page 19: ...manufacturer code 5th to 14th bits are the device code 15th to 20th bits are the site code and the 21st to 36th bits are the card number Wiegand50 ESSSSSSSSSSSSSSSSCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCCO Co...

Page 20: ...e output value of failed user verification The output format depends on the Wiegand Format setting The default value ranges from 0 to 65535 Site Code It is similar to device ID except that it can be s...

Page 21: ...ample adjust the clock forward one hour at 08 00 on April 1 and backward one hour at 08 00 on October 1 Daylight Saving Mode Select the date mode or week mode Daylight Saving Setup Set the DST start t...

Page 22: ...to delete attendance Data one time The valid value is 1 999 Confirm Screen Delay s The delay to display the verification result the value is 1 9 Expiration Rule The choices for the function of the use...

Page 23: ...ication or Password Verification users might forget the registered fingerprint or password or press the finger improperly To reduce the process of re entering user ID retry is allowed the number of re...

Page 24: ...id value scope is 60 99999 seconds Idle Time To Slide Show s When standby time in main screen is larger than this value the main screen will display a slide show The valid value scope is 3 999 seconds...

Page 25: ...minal Select ON to enable the voice prompt and select OFF to mute Keyboard Prompt This parameter is used to set whether to generate beep sound in response to every keyboard touch Select ON to enable t...

Page 26: ...ction of external ringing is used set the output terminal of external ringing Punch State Options To set the mode of state keys Enter into Personalize Punch State Options 1 Select a bell to edit 2 Pre...

Page 27: ...Check In Check Out Overtime In and Overtime Out Shortcut Key Mappings You can define six shortcut keys as attendance status shortcut keys or functional shortcut keys On the main interface of the FFR...

Page 28: ...Function Select punch state options or menu function options Name Enter the name of punch state Set Switch Time Set switch time for punch state...

Page 29: ...ata Delete All Data Delete all enrolled users information fingerprints attendance records short messages and work codes etc Delete Admin Role Change all administrators into normal users Delete Access...

Page 30: ...device 1 Select a route 2 Select the data type 3 Start the restore Note When restoring data from a USB Disk you need to insert a USB Disk into the device at first which has the restored data 10 Acces...

Page 31: ...ludes None Normal Open NO and Normal Close NC None means door sensor is not in use Normal Open means the door is opened when electricity is on Normal Close means the door is closed when electricity is...

Page 32: ...NO time period valid holidays speaker alarm device status duress function alarm on 1 1 match alarm on 1 N match alarm on password and alarm delay However the content of the Access Data Deletion in Da...

Page 33: ...d time and time period As shown in above figure Holiday 1 starts on the October 1 every year ends on the October 3 every year Creating Access Groups Grouping is to manage users in groups Group users d...

Page 34: ...ingerprint only Time Zone 1 2 and 3 are set while the Holiday function is enabled Multi user Authentication Combine two or more members to achieve multi verification and improve security In a Combined...

Page 35: ...state no alarm signal will be triggered Alarm on 1 N Match In ON state when a user uses 1 N Verification Method to verify any registered fingerprint alarm will be triggered In OFF state no alarm signa...

Page 36: ...ata Download all user data to USB disk User Portrait Download attendance photos to USB disk Work Code Download all work codes to USB disk Short Message Download all short messages to USB disk Screen S...

Page 37: ...s which are Gregorian Iran Gregorian and Iran Lunar Attendance Record Search the attendance records in the device When you have verified in the device the record is saved Attendance photo Search the a...

Page 38: ...t attendance records out when a printer is connected Data Field Setup In the initial interface press M OK Print Data Field Setup press M OK to turn on off the fields needing to be printed 3 The record...

Page 39: ...showing interface will back to initial interface after reaching Message Show Delay The valid value is 1 99999 seconds Salary is based on attendance There are many work types for employees An employee...

Page 40: ...king number The range is 1 99999999 Name Input a name with T9 input 23 characters are limited Note The work code cannot be modified once confirmed 1 Select a work code 2 Press Edit to modify the name...

Page 41: ...rprint Sensor Checks if the fingerprint sensor is available to use Test Clock RTC Checks if the RTC Real Time Clock is accurate While checking modules please follow the prompts in the specific interfa...

Page 42: ...ethods Enter into New Message Press 4 twice to input H Input appy with the same way Press to symbol type Press to find to 4 Input New Year with that way Press 4 to input a blank Press to numeric type...

Page 43: ...er is smaller or equal 30K There is no limit on the name and format of the screen saver Wallpaper First create a directory named wallpaper in the root directory of USB disk and then put wallpapers in...

Page 44: ...Lead Pb Mercury Hg Cadmiu m Cd Hexavalen t chromium Cr6 Polybrominate d Biphenyls PBB Polybrominate d Diphenyl Ethers PBDE Chip Resistor Chip Capacitor Chip Inductor Diode ESD component Buzzer Adapte...

Page 45: ......

Reviews: