background image

ALF-13120-E-02

All-Flo

5

PRINCIPLES OF OPERATION

The air-valve directs pressurized air behind the diaphragm on the right, 

causing the diaphragm on the right to move outward (to the right).
Since both the right diaphragm and the left diaphragm are connected  

via a diaphragm rod, when the right diaphragm moves to the right, the 

left diaphragm (through the action of the diaphragm rod) moves to the 

right also.
When the diaphragm on the left side is moving to the right, it is referred 

to as suction stroke. When the left diaphragm is in its suction stroke,  

the left suction ball moves upward (opens) and the left discharge ball 

moves downward (closes). This action creates suction and draws liquid 

into the left side chamber.

The air-valve directs pressurized air behind the left diaphragm, causing 

the left diaphragm to move outward (to the left).
Since both the left diaphragm and the right diaphragm are connected  

via a diaphragm rod, when the left diaphragm moves to the left, the  

right diaphragm (through the action of the diaphragm rod) moves to  

the left also.
When the diaphragm on the left side moves outward, the left discharge ball 

moves upward (opens) and the left suction ball moves downward (closes). 

This causes the liquid to leave the left side liquid outlet of the pump.
Simultaneously, the right diaphragm moves inward (to the left), which 

causes the right suction ball to open and the right discharge to close, 

which in turn causes suction, drawing liquid into the right chamber.
The process of alternating right suction / left discharge (and vice-versa) 

continues as long as compressed air is supplied to the pump.

HOW AN AIR OPERATED DOUBLE  

DIAPHRAGM PUMP WORKS

SECTION

3

Note: The graphics show ball valves, which are replaced with Max-Pass™ 

valves for these pump models.

Summary of Contents for Max-Pass S Series

Page 1: ...IOM INSTALLATION OPERATION MAINTENANCE S038 PLASTIC 3 8 INCH AIR OPERATED DOUBLE DIAPHRAGM PUMP ...

Page 2: ...NGS 6 SECTION 5 PERFORMANCE CURVE 7 SECTION 6 INSTALLATION TROUBLESHOOTING AND MAINTENANCE INSTALLATION 8 9 TROUBLESHOOTING 10 OPERATION 11 MAINTENANCE 11 SECTION 7 REPAIR AND ASSEMBLY PUMP WET END REMOVAL 12 13 AIR VALVE REMOVAL 14 15 TORQUE SPECIFICATIONS 15 SECTION 8 EXPLODED VIEWS AND PARTS LISTS 16 17 SECTION 9 ELASTOMERS AND REPAIR KITS 18 SECTION 10 WARRANTY AND REGISTRATION 19 ...

Page 3: ...pumped Consult a chemical resistance guide for chemical compatibility and a more precise safe temperature limit Always use minimum air pressure when pumping at elevated temperatures CAUTION It is the end user s responsibility to maintain the process fluid s temperature during use CAUTION Ensure all wetted components are chemically compatible with the process fluid and the cleaning fluid CAUTIONS R...

Page 4: ...FE Coated Stainless Steel Hardware Premium Muffler F Stainless Steel Hardware Standard Muffler Grounding Lug Installed G Stainless Steel Hardware Premium Muffler Grounding Lug Installed H PTFE Coated Stainless Steel Hardware Standard Muffler Grounding Lug Installed I PTFE Coated Stainless Steel Hardware Premium Muffler Grounding Lug Installed Note Equipment must be grounded to achieve ATEX rating ...

Page 5: ... causing the left diaphragm to move outward to the left Since both the left diaphragm and the right diaphragm are connected via a diaphragm rod when the left diaphragm moves to the left the right diaphragm through the action of the diaphragm rod moves to the left also When the diaphragm on the left side moves outward the left discharge ball moves upward opens and the left suction ball moves downwa...

Page 6: ...ALF 13120 E 02 All Flo 6 3 8 PUMP DIMENSIONS PLASTIC SOLIDS SECTION 4 ...

Page 7: ...lene Conductive Nylon 3 8 lbs 1 7 kg Weight PVDF 5 lbs 2 3 kg Air Inlet 1 4 FNPT Liquid Inlet FNPT FBSPT 3 8 Liquid Outlet FNPT FBSPT 3 8 Height 7 19 182 6 mm Width 8 55 217 2 mm Depth 4 82 122 4 mm 5 SECTION Flow rates indicated on the chart s shown were determined by pumping water at flooded suction For optimum life and performance pumps should be specified so that daily operation parameters wil...

Page 8: ...tion it is recommended to pipe the exhaust air above the liquid source In the event of a diaphragm failure this will reduce or eliminate the possibility of liquid discharging through the exhaust onto the ground LOCATION Ensure that the pump is installed in an accessible location in order to facilitate future service and maintenance AIR Ensure that the air supply is sufficient for the volume of air...

Page 9: ...ALF 13120 E 02 All Flo 9 SUGGESTED INSTALLATION This illustration is a generic representation of an air operated double diaphragm pump ...

Page 10: ...d Suction valve closed Suction line plugged No liquid in the suction tank Suction lift excessive Debris stuck in valves Excessive wear of check valves Air leak on suction side with suction lift Pump Cycles with Closed Discharge Valve Debris stuck in check valve Excessive wear of check valves Pump Running Slowly Not Steady Air compressor undersized Leak in air supply Air line filter regulator or ne...

Page 11: ...and the pump Do not use valves for flow control on the suction side of the pump Closing or partially closing a liquid suction valve restrict the suction line and may cause damage to the diaphragms Suction strainers may be employed to reduce or eliminate larger solids but routine maintenance is necessary in order to prevent a restriction on the suction MAINTENANCE Due to the unique nature of each a...

Page 12: ...safe manner WARNING Maintenance must not be performed when a hazardous atmo sphere is present STEP 1 Using the 7 16 inch wrenches remove four Hex Head Cap Screws eight Washers and four Hex Nuts from the Discharge Manifold Outer Chamber and Suction Manifold STEP 4 Set the Intermediate with attached Outer Chambers aside STEP 2 Remove the Discharge Manifold STEP 5 Remove the Suction Manifold STEP 3 R...

Page 13: ...nti seize compound to the thread Note When using pumps built with PTFE O Rings always replace with new PTFE O Rings since the original O Rings may not reseal the pump STEP 7 In order to remove both Outer Chambers using the inch wrench remove the Chamber Clamps from each side of the Intermediate STEP 10 Placing the 3 4 inch wrench on the remaining Outer Diaphragm Plate and the straight blade screwd...

Page 14: ...64 Inch 3mm WARNING Prior to servicing the pump ensure that the air and fluid lines are closed and disconnected While wearing personal protective equip ment flush drain and process liquid from the pump in a safe manner WARNING Maintenance must not be performed when a hazardous atmo sphere is present STEP 4 STEP 5 STEP 6 Remove the Air Valve from the Intermediate Set the mechanism to the the Hard S...

Page 15: ...seals are both facing each other inward Lubrication of the air valve assembly with a non synthetic lubricant is recommended Magna Lube or Magna Plate are recommended for assembly lubrication see detailed parts list for ordering information Note If the lip seals are installed incorrectly they will be unable to rotate TORQUE SPECIFICATION CHART RECOMMENDED TORQUE SPECIFICATIONS 3 8 Pumps Manifold Bo...

Page 16: ...ALF 13120 E 02 All Flo 16 EXPLODED VIEW PARTS LIST S038 SQ PLASTIC SOLIDS SECTION 8 ...

Page 17: ...E 11938 15 EPDM S038 SQ T 11938 17 PTFE S038 SQ V 11938 82 VFKM 13 MAX PASS VALVE 4 S038 SQ N 10915 11 Nitrile S038 SQ V 10915 13 FKM S038 SQ E 10915 15 EPDM 14 MAX PASS BACKUP 4 S038 SQP 10916 40 Polypropylene S038 SQY 10916 46 Conductive Nylon S038 SQK 10916 56 PVDF 15 MAX PASS SLEEVE 4 S038 SQP 10917 40 Polypropylene S038 SQY 10917 42 Nylon S038 SQK 10917 56 PVDF 16 OUTER CHAMBER 2 S038 SQP 107...

Page 18: ...ature range 10 F to 180 F 12 C to 82 C EPDM is a general purpose elastomer with good resistance to many acids and bases Temperature range 40 F to 280 F 40 C to 138 C SANTOPRENE is an injection molded material with characteristics similar to EPDM Has excellent abrasion resistance Temperature range 40 F to 225 F 40 C to 107 C PTFE POLYTETRAFLUOROETHYLENE is a thermoplastic polymer that is inert to m...

Page 19: ...NTIES WHETHER EXPRESS IMPLIED OR ORAL INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND ANY IMPLIED WARRANTIES OTHERWISE ARISING FROM A COURSE OF DEALING OR TRADE All Flo will not in ANY event be liable for any loss of profit interruption of business or any other special consequential or incidental damages suffered or sustained by Custom...

Page 20: ...designing and manufacturing the highest quality product available to industry Since the beginning in 1986 All Flo engineers have used their extensive knowledge of today s engineered materials advanced air system logic and manufacturing techniques to develop the superior group of lube free air operated diaphragm pumps found in this catalog Every pump is performance engineered and quality built to p...

Reviews: