ALF-13120-E-02
All-Flo
4
MODEL DESIGNATION MATRIX-
PLASTIC SOLIDS
SECTION
2
PR
ODUC
T SERIE
S
FL
UID CONNE
CTION T
YPE
LIQ
UID SE
CTION
DIAPHRA
GM
VAL
VE/B
ALL
VAL
VE SEA
T/B
ACK
UP
O-RINGS
SPE
CIAL (
OTHER)
SPE
CIAL (P
OR
TING)
AIR SE
CTION
SPE
CIAL (HARD
WARE,
MUFFLER)
S 0 3 8
-
1 2
3
- 4 5 6 7 - 8 9 10
FLUID CONNECTION TYPE
S = NPS (NPT/BSP)
AIR SECTION
Q = Polypropylene Intermediate-Mechanical Shift
LIQUID SECTION
K = PVDF
P = Polypropylene
Y = Conductive Nylon
DIAPHRAGMS
G = Geolast
®
S = Santoprene
®
T = PTFE
VALVE/BALL
N = Buna-N Max-Pass
™
E = EPDM Max-Pass
™
V = FKM Max-Pass
™
VALVE SEAT/BACKUP
K = PVDF
P = Polypropylene
Y = Conductive Nylon
O-RINGS
E = EPDM
N = Buna-N
T = PTFE
V = FKM
PORTING
S = Default (Suction Right/ Discharge Right)
T = Suction Right / Discharge Left
X = Suction Left / Discharge Right
Y = Suction Left / Discharge Left
K = Suction Bottom / Discharge Center Front
L = Suction Bottom / Discharge Center Rear
N = Suction Bottom / Discharge Right
O = Suction Bottom / Discharge Left
P = Suction Right / Discharge Center Front
Q = Suction Right / Discharge Center Rear
U = Suction Left / Discharge Center Front
V = Suction Left / Discharge Center Rear
SPECIAL OPTION (HARDWARE,
MUFFLER, LUG)
7 = Stainless Steel Hardware, Standard Muffler
8 = Stainless Steel Hardware, Premium Muffler
B = PTFE Coated Stainless Steel Hardware,
Standard Muffler
C = PTFE Coated Stainless Steel Hardware,
Premium Muffler
F = Stainless Steel Hardware, Standard Muffler,
Grounding Lug Installed
G = Stainless Steel Hardware, Premium Muffler,
Grounding Lug Installed
H = PTFE Coated Stainless Steel Hardware,
Standard Muffler, Grounding Lug Installed
I = PTFE Coated Stainless Steel Hardware,
Premium Muffler, Grounding Lug Installed
Note: Equipment must be grounded to achieve
ATEX rating it is recommended to configure
the pump with a grounding lug option for
ATEX applications.
SPECIAL OPTION (OTHER)
0 = Standard
1 = Cycle Counter Valve
2 = Solenoid Adaptor Valve 110/50 Volt AC, 120/60
Volt AC, DIN 43650B Connector
3 = Solenoid Adaptor Valve 110/50 Volt AC, 120/60
Volt AC Explosion Proof
4 = Solenoid Adaptor Valve 220/50 Volt AC, 240/60
Volt AC, 12 Volt DC, DIN 43650B Connector
5 = Solenoid Adaptor Valve 220/50 Volt AC, 240/60
Volt AC, 12 Volt DC Explosion Proof
6 = Solenoid Adaptor Valve 220/50 Volt AC, 240/60
Volt AC, 125 Volt DC, DIN 43650B Connector
7 = Solenoid Adaptor Valve 220/50 Volt AC, 240/60
Volt AC, 125 Volt DC Explosion Proof
8 = Solenoid Adaptor Valve 24 Volt DC, DIN
43650B Connector
9 = Solenoid Adaptor Valve 24 Volt DC, Explosion
Proof
A = Grease Free (No lubrication assembly)
SIZE
WET END REPAIR KIT
Wet end kits are available and
consist of 2 diaphragms, (back-up
diaphragms if required), 4 MaxPass
valves and 4 seat O-Rings.
See matrix below.
1
2
6
7
8
9
10
Bold indicates recommended options
DIAPHRA
GM
VAL
VE/B
ALL
O-RINGS
S
W
E
-
0
3
8
-
4
5
X
7
-
P
PR
ODUC
T
SERIE
S
WET END
REP
AIR KIT
PUMP SIZE
3
4
5
MA
TERIAL