8
Ioline CrystalPress User Guide
Safety Labels
The following labels are used to identify potential hazards on the
equipment.
Shock Hazard
Dangerous voltages are located near this
label. Beware of an electrical shock haz-
ard during use and disassembly.
Crush Hazard
Machinery near this label may crush
body parts. Beware of the mechanism.
Side Crush Hazard
Machinery near this label may crush
body parts with a sideways force. Beware
of moving parts.
Earth Ground
An electrical connection near this label
provides an earth ground circuit.
See the maintenance section for information on proper procedures
for keeping safety mechanisms in working order.
Specifications and Environment
System specifications and environment requirements for the Ioline
CrystalPress
are listed below:
Ioline Part Number
109770
Height
310 mm (12 in.)
Width
1120 mm (44 in.)
Depth
180 mm (7 in.)
Installed Weight
21 Kg (45 lbs.)
Motif Design Area
343 x 318 mm (13.5 x 12.5 in)
Crystal Sizes
6ss, 10ss 12ss, 16ss, 20ss, and 30ss
I/O
USB or RS-232 Serial
Data Type
HPGL 7475 or DXF
Input Voltage
85 - 264 VAC, single phase
Input Current
2.5 A maximum
Input Frequency
50-60 Hz
Short Circuit Protection
Protection on all outputs at
110-145% peak.
Operating Temperature
0° - 50°C (32° - 122° F)
Humidity
Non-condensing