DOLPHIN
8A
Make the Connections
Connect the required wires using the Dolphin crimps provided in the IXM Install Kit (or any similar crimps) and a ratchet style
crimping tool. Insert two wires (no stripping required) into the open end of the crimp and then using the crimping tool, clamp
down on the middle of the crimp.
8B
Connect Earth Ground
Connect the lug of the Earth Ground wire directly to the front of the mounting plate using one of the Wall
mounting screws. Ensure that the lug is secured tightly so as to make the necessary contact between the
device and the mounting plate. Connect the other end of the Earth Ground wire to the Earth Ground
connection of the install site with a crimp.
Ensure all required connections are made to each device in the setup prior to turning on the power.
Checklist:
Connections for Power & Ground (DC or PoE+)
Connections for Communications (Ethernet, RS-485, RS-232 or USB)
Connections for Operation (ACP or DAC)
Any other connections that may be required based on the application (SPO or SPI)
Copyright 2019
INVIXIUM
15
Earth Ground
Wire Lug