background image

Ethernet and Wi-Fi Communication

Ethernet:

• 

Switch/Router required

• 

CAT 5 cabling or better

WiFi:

• 

Wireless router to LAN/WAN

 

• 

802.11ac protocol

 

• 

WEP, WPA and WPA2 encryptions supported

 

• 

DHCP enabled by default

TITAN FPLV

TITAN FPU

TITAN FV

Router connected

to LAN/WAN 

Router connected

to LAN/WAN 

IXM WEB

IXM WEB

Copyright     2019

INVIXIUM

19

Summary of Contents for IXM TITAN

Page 1: ...IXM TITAN Installation Guide ...

Page 2: ...ut Hardware Tools Required For Installation Hardware Installation Steps Connections for Power Connections for Communication Connections for Operation Connections for HDMI Out Software Installation System Requirements Software Installation Steps Notices Support 3 4 5 6 7 10 11 12 13 17 19 23 26 27 28 30 34 Table of Contents Copyright 2019 INVIXIUM ...

Page 3: ...g Diode NC Normally Closed NO Normally Open OTG On the Go RLY Relay RX Receive SGND Signal Ground SPI Specific Purpose Input SPO Specific Purpose Output TX Transmit USB Universal Serial Bus WDATA Wiegand Data WGND Wiegand Ground VDC Volts Direct Current VIN Power Positive 12 24 VDC VIN Power Return Glossary 3 Metal Mounting Plate Wired Back Cover Temporary Back Cover Copyright 2019 INVIXIUM ...

Page 4: ...e lug of the Earth Ground wire should be fastened with a screw to the front of the mounting plate The other end of the Earth Ground wire should be connected to the high quality Earth Ground connection on site When the IXM device is installed onto the mounting plate this Earth Ground lug will make direct contact with the Metal Back plate of the IXM device thus allowing for proper grounding Please r...

Page 5: ...open or disassemble the device as this will void the product warranty Do not deploy for any use other than its intended purpose Do not insert anything other than the correct fitting USB plug into the USB port located at the bottom of the device Device Handling Don ts The component that will require most frequent cleaning is the sensor as it experiences the most contact The cleaning should be perfo...

Page 6: ...over D O LP H IN D O L P H IN D O L P H IN D O L P H IN D O L P H IN DO LPH IN D O L P H IN D O L P H IN D O L P H IN D O L P H IN D O LP H IN D O LP H IN DO LP HI N DO LP HI N Dolphin Crimps qty 12 Hex Key Earth Ground Wire Metal Mounting Plate Screw qty 2 Wall Mounting Screws qty 6 INVIX Micro USB Extension Cable ...

Page 7: ...olor LEDs Mic Corning Gorilla Glass Surge Protection Proximity Sensor 5 0 IPS LCD IP67 IK10 21 Megapixel Camera Aluminium Enclosure Industrial Grade Connectors High intensity LED Flash Fingerprint or Finger Vein Sensor Aluminium 5 0 IPS LCD ...

Page 8: ...Copyright 2019 INVIXIUM 8 270 89 93 30 19 50 89 13 81 60 ...

Page 9: ...roduct Mounting Plate Actual Dimensions in mm INVIXIUM recommends printing this page in Actual Size Copyright 2019 INVIXIUM 9 Angled Front View Side View 9 50 4 20 Front View 110 233 56 76 60 261 42 82 10 B 30 ...

Page 10: ...ve Reserved for Future Use Earth Ground RS232_TX Green Red Orange White Green Red Green Yellow Black Red Blue Red Blue Green Red Blue Black White Red Green White Grey White Black Grey Red Purple White RS232 Data Transmit Signal Ground RS485 Terminated Optional RS485 Non Inverting Line Reserved for Future Use RS485 Inverting Line Relay NC Wiegand Data Input Line 0 Relay Common Wiegand Data Input Li...

Page 11: ...2 Reserved for Future Use Specific Purpose Output Line 3 ACP LED 1 Feedback Ground for SPOs ACP LED 2 Feedback Specific Purpose Input Line 1 Ground for ACP LED Feedback Specific Purpose Input Line 2 DAC Input 1 Specific Purpose Input Line 3 DAC Input 2 Wire Wire Color Wired Back Cover 23 24 25 26 27 28 29 USB0_VBUS USB1_VBUS USB0_D USB1_D USB0_D USB1_D USB0_GND USB Line 0 Host interface USB Line 1...

Page 12: ...ce the Power Drill and Hammer may not be required Installation of any IXM device should be performed by licensed electricians NOTE Pencil Hammer Power Drill Ratchet style Crimping tool Measuring Tape Battery powered Screwdriver Manual Screwdriver Copyright 2019 INVIXIUM 12 ...

Page 13: ...mmends the use of all 6 holes for mounting Refer to diagrams from page 9 onwards for actual dimensions Ideal mounting height is 115 120 cm from the ground to the bottom of the device But also be sure to align the device in case of multiple installations Copyright 2019 INVIXIUM 13 ON OFF Holes for mounting on Gang box Single Gang DO LPH IN DO LP HIN DO LP HI N DO LP HI N DO LP HI N DOLP HIN DO LP H...

Page 14: ...ough the square hole of the mounting plate 7 Identify the Connections DC Power VIN VIN EGND PoE RJ 45 Receptacle EGND Power Grounding 1 Communications RS 485 SGND RS 485 RS 485 Ethernet RJ 45 Receptacle USB RS 232 RS 232_RX RS 232_TX SGND Operations ACP ACP_LED1 ACP_LED2 ACP_LED_GND WDATA_OUT0 WDATA_OUT1 WGND DAC RLY_NC RLY_COM RLY_NO DAC_IN1 DAC_IN2 DAC_OUT DAC_SUPPLY 2 3 OR OR OR OR OR Refer to ...

Page 15: ... one of the Wall mounting screws Ensure that the lug is secured tightly so as to make the necessary contact between the device and the mounting plate Connect the other end of the Earth Ground wire to the Earth Ground connection of the install site with a crimp Ensure all required connections are made to each device in the setup prior to turning on the power Checklist Connections for Power Ground D...

Page 16: ...nnect the Wired Back Cover to the back of the device by lining up the connectors Secure the Wired Back Cover with the same screws Next hang the IXM device onto the mounting plate as shown in the series of diagrams below 1 2 Finally secure the device on the bottom to the mounting plate with the Metal Mounting Plate screw provided in the IXM Install Kit ...

Page 17: ...up or UPS with built in surge protection If sharing power supplies ensure that each TITAN is supplied with minimum 2A per device i e Powering 2 devices will require a supply with output current of 4A Power Connections VIN VIN EGND Product Warranty is void if improper power under or over is supplied to the device WARNING TITAN DC Power Supply UPS EGND VIN VIN UPS Copyright 2019 INVIXIUM 17 ...

Page 18: ...battery back up or UPS with built in surge protection Available on MERGE SENSE 2 TOUCH 2 and TITAN Connections for Power Over Ethernet PoE Both IEEE 802 3at power transmission modes A and B are supported NOTE TITAN FPU TITAN FV Ethernet PoE Connections TX TX RJ45_PIN4 RX RX RJ45_PIN7 Copyright 2019 INVIXIUM 18 ...

Page 19: ... CAT 5 cabling or better WiFi Wireless router to LAN WAN 802 11ac protocol WEP WPA and WPA2 encryptions supported DHCP enabled by default TITAN FPLV TITAN FPU TITAN FV Router connected to LAN WAN Router connected to LAN WAN IXM WEB IXM WEB Copyright 2019 INVIXIUM 19 ...

Page 20: ...ted not included refer to NOTE below for correct Resistor vaues Connect the IXM device to PC via RS 485 to Serial RS 232 or USB Converter Maximum cable length of 1200m 4000 ft at 9600 bps baud rate R 120 ohms for Standard RS 485 Cabling R 100 ohms for CAT5 6 Cabling NOTE RS 485 Connections SGND RS485_D RS485_D 6 8 10 RS 485 to USB Converter IXM WEB TITAN Copyright 2019 INVIXIUM 20 ...

Page 21: ...he DB9 Serial port of the PC if available DB9 connectors and cables are not included RS 232 Connections RS 232_RX RS 232_TX SGND 2 4 6 USB to Serial Converter TITAN RS232_RX RS232_TX SGND 1 2 3 4 5 IXM WEB B to Serial Converter IXM WEB Copyright 2019 INVIXIUM 21 ...

Page 22: ...wnloading transaction logs USB port can also be used to connect to a PC running IXM WEB via Micro USB cable Driver installation is required and will automatically initiate once the device is connected Host PC Micro USB Cable TITAN USB Communication Copyright 2019 INVIXIUM 22 Micro USB Cable TITAN TITAN ...

Page 23: ...D ACP LED and Wiegand connections available for ACP operation INVIXIUM recommends the use of Wiegand Output Data 0 1 and GND connection ACP_LED signals can be used if available on the Access Control Panel IXM devices support up to 2 wires GND for LED status NOTE Copyright 2019 INVIXIUM 23 TITAN WDATA_OUT0 WDATA_OUT1 WGND ACP_LED1 ACP_LED2 ACP_LED_GND TITAN ...

Page 24: ...tector instead of Request to Exit buttom connect the following signals 1 DAC_OUT to the COM and 2 DAC_IN2 to the Relay NO of the motion detector Door Access Control Connections for TITAN DAC Connections Top DAC Connections Bottom RLY_NC RLY_COM RLY_NO DAC_IN1 DAC_IN2 DAC_OUT 11 13 15 13 15 18 Copyright 2019 INVIXIUM 24 RLY_NO DAC_IN1 RLY_COM DAC_OUT DAC_OUT DAC_IN2 Snubber Diode Door Strike Door C...

Page 25: ...Door Strike Internal Relay rated upto max of 2A 24 VDC For motion detector instead of Request to Exit buttom connect the following signals 1 DAC_OUT to the COM and 2 DAC_IN2 to the Relay NO of the motion detector DAC Connections for TITAN when Device Powers Door Strike DAC_SUPPLY DAC_IN_GND 1 19 Copyright 2019 INVIXIUM 25 RLY_NO DAC_IN1 DAC_SUPPLY VIN RLY_COM DAC_OUT DAC_OUT DAC_IN2 Snubber Diode ...

Page 26: ...at can be used for real time Video Surveillance for standalone installations When the HDMI out is connected to a monitor via an HDMI cable sold separately the monitor screen will show the user the TITAN Field of View when in surveillance mode For security purposes the HDMI cable can be connected to a monitor behind the door i e on the inside to see what is happening on the outside Monitor ...

Page 27: ...equirements To successfully install and run IXM WEB the system must meet the following minimum requirements One of the following Operating Systems Windows 10 8 1 and 7 32 Bit 64 Bit Windows 7 Home Premium Edition Windows Server 2016 2012 2012 R2 2008 2008 R2 Internet Explorer version 11 0 Google Chrome version 40 0 and above Mozilla Firefox version 40 0 and above Microsoft Edge version 38 14393 an...

Page 28: ...tep 3 There are two installation options Install or Advanced INVIXIUM recommends selecting INSTALL option for rapid installation A Windows dialog may pop up to provide a warning about installing from an unreliable source Click Yes to proceed with the install The ADVANCED process allows for entering a different install path entering a specific Port number checkbox for installing SQL Server database...

Page 29: ...installation is complete click EXIT IXM WEB icon is now on the desktop Step 6 Run IXM WEB to launch the application in the default web browser to setup the Database and Admin credentials Step 6 Visit the Invixium Customer Portal for more detailed manuals on invixium com Copyright 2019 INVIXIUM 29 ...

Page 30: ...15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruc tions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a par...

Page 31: ...rique de Classe B conformément à la partie 15 des règles de la FCC Ces limites sont conçues pour fournir une protection raisonnable contre les interférences nuisibles dans une installation résidentielle Cet équipement génère utilise et peut émettre des fréquences radio et s il n est pas installé et utilisé conformément aux instructions il peut causer des interférences nuisibles pour les communicat...

Page 32: ...ateurs en Français This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 This device may not cause interference 2 This device must accept any interference including interference that may cause undesired operation of the devic Industry Canada Information to Users English Cet appareil est conforme avec Industrie Canada exempts ...

Page 33: ...hority to operate the equipment Warning to Users English WARNING Les changements ou modifications non expressément approuvés par INVIXIUM pourraient annuler l autorité de l utilisateur à utiliser l équipement Avertissement aux Utilisateurs en Français WARNING Copyright 2019 INVIXIUM 33 ...

Page 34: ...GUIDE Some features may vary based on device models Copyright 2019 INVIXIUM All rights reserved P N XAD 00E 151 02G INVIXIUM COM 2018 Google Inc All rights reserved Chrome browser is a trademark of Google Inc Firefox logo is a registered trademark of the Mozilla Foundation Windows Edge and Internet Explorer are trademarks of the Microsoft group of companies Safari is a trademark of Apple Inc Enjoy...

Reviews: