DAC:
•
INVIXIUM recommends a separate power supply for Door Strike (not included) for this configuration
•
Snubber Diode required for Door Strike (not included)
•
Example above shows use of RLY_NO, but RLY_NC may be used instead if required by the Door Strike
•
Internal Relay rated upto max of 2A @ 24VDC
•
For motion detector instead of Request-to-Exit-buttom, connect the following signals:
(1) DAC_OUT to the COM and (2) DAC_IN2 to the Relay NO of the motion detector
Door Access Control Connections for TITAN
DAC Connections (Top)
DAC Connections (Bottom)
RLY_NC
RLY_COM
RLY_NO
DAC_IN1
DAC_IN2
DAC_OUT
(11)
(13)
(15)
(13)
(15)
(18)
Copyright 2019
INVIXIUM
24
RLY_NO
DAC_IN1
RLY_COM
DAC_OUT
DAC_OUT
DAC_IN2
Snubber Diode
Door
Strike
Door
Contact
Request
to exit
TITAN
RLY_NO
L
L
DAC_IN1
RLY_COM
L
L
DAC_OUT
DA
DA
TITAN
Door Strike Power Supply