Max Relay rating = 2A @ 24VDC
Device can supply 500mA@12V
NOTE: This connection diagram is valid for TOUCH 2 and SENSE 2 only
DAC Connections (Device Powers Door Strike)
DAC Connections
RLY_COM
RLY_NO
DAC_IN1
DAC_IN2
DAC_OUT
(3)
(5)
(13)
(15)
(18)
(20)
RLY_NO
DAC_IN1
DAC_DSP
DAC_GND
RLY_COM
DAC_OUT
DAC_OUT
DAC_IN2
Snubber Diode
Electric
Door Strike
Door Contact
Request
to exit
TOUCH 2
DAC_DSP
(19)
DAC_GND
+
-
Note: For a magnetic lock, please
use RLY_NC wire as shown on
the previous page.