8
InvisibleFence.com
Shields® System Operation - Continued
• Adjust Signal Field Range
o Determine the desired location and the signal field range required.
• Wireless: 13 inch minimum up to 38 inch maximum signal field height.
o With the unit
ON
, press the
RANGE UP (+) or the RANGE DOWN (-)
buttons to increase
or decrease the signal field range. The first indicator equals 13 inches of signal field. Each
additional number represents approximately 6 inches of range.
DISPLAY
APPROX. HEIGHT
1
13
2
19
3
25
4
31
5
38
• Verify Signal Field Range
o Holding the Computer Collar®, start
outside the range and move slowly
towards the Shields® Gate transmitter.
Do not touch the correction posts at
this time.
o The Computer Collar will beep as it
approaches the outer range of the
signal field width set in Step 2. The
beeping will be accompanied by a
correction.
o If the Computer Collar fails to beep,
see the troubleshooting chart on
page 11.
o Adjust range and/or relocate Shields Gate transmitter desired area is protected.
• Changing the Channel Setting on Shields Gate transmitter
o Remove the control panel cover. (See photo on page 6 for location)
o Press and release the
RANGE DOWN (-)
button until 0 appears on the LCD.
o Locate the switch for the
Channel (A), Channel (B) and (A+B) Channel.
o Select the desired channel setting.
Note: Shields Gate will not enter into programming
mode if the switch is set to A+B. See Programming Computer Collar on Page 10
o Adjust and verify signal field range.
o Replace the control panel cover and hand tighten the screws.
120% of height
120% of height
85% of
height
85% of
height