background image

7

InvisibleFence.com

Control Panel

Turn the Shields® Gate transmitter over and rotate the control panel cover screw holding the 
control panel cover. Refer to page 6; Bottom View image. 

 

• Slide Switches

 

 

o  

BOUNDARY PLUS® /SHIELDS® Mode

 – Sets how the Computer Collar® will react to 

Shields Gate. Set to Boundary Plus® mode, activation will occur as your pet crosses 
the transmitter. Set to Shields mode, activation occurs as you pet approaches the 
transmitter.

 

 

o  

7K/10K FREQ

 – System frequency set by Invisible Fence® dealer.

 

 

o  

ON/OFF MOTION

 – Turns motion sensing on or off. “On” mode allows your Shields Gate 

to go into a sleep mode that wakes as it detects motion to save battery life.

 

 

o  

1/2/3 RATE

 – Sets the data rate of the signal. Used to increase battery life. Rate 1 is the 

the slowest and consumes the least energy. Rate 3 is the fastest and consumes the most 
energy. The faster the data rate, the 
more consistent the boundary.

 

 

o  

A+B/B/A CODE

 -   Data types used 

to separate pet when unit is set to 
Shields mode. This switch is unused 
in Boundary Plus mode. Refer to 
Different Rules for Different Pets™ 
technology section.

 

• Range and Program Buttons

 

 

o  

+ & - Buttons 

- Used to adjust the 

signal field range. Press simultaneously to lock/unlock the height.

 

 

o  

P Button

 – Used to program the Computer Collar® to Channel A or B when setting 

Different Rules for Different Pets™ technology

Shields System Operation:

In Shields mode, your pet’s Computer Collar will activate as it approaches Shields Gate’s  
oval-shaped Invisible Boundary® design. This allows you to protect large areas such as couches, 
tables and entry ways. Shields mode also allows you to deny access to one pet while allowing 
access to another with patented Different Rules for Different Pets technology. Ensure the  

BOUNDARY/SHIELDS

 switch is in the Shields position. 

Summary of Contents for Shields Gate

Page 1: ...Invisible Fence Indoor Solutions Shields Gate Owner s Manual InvisibleFence com...

Page 2: ...sult in death or serious injury CAUTION used with the safety alert symbol indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE is used to address safe u...

Page 3: ...t avoidance containment system All Invisible Fence systems are designed for domesticated animal use only Never attempt to use this product for any purpose not specifically described in this manual The...

Page 4: ...ange 8 Changing the Channel Setting 8 Boundary Plus System Operation 9 Adjust Signal Field Range 9 Verify Signal Field Range 9 Multi Area Avoidance 10 Programming the Computer Collar Unit 10 Linking M...

Page 5: ...rechargeable battery pack You may use the included AC adapter for locations near an electrical outlet The AC adapter is also used for charging the transmitter The Transmitter has four control buttons...

Page 6: ...l illuminate red while charging o The power button will illuminate green when charging is complete Battery life of approximately 30 days can be expected from a fully charged battery The Shields Gate t...

Page 7: ...nergy Rate 3 is the fastest and consumes the most energy The faster the data rate the more consistent the boundary o A B B A CODE Data types used to separate pet when unit is set to Shields mode This...

Page 8: ...omputer Collar will beep as it approaches the outer range of the signal field width set in Step 2 The beeping will be accompanied by a correction o If the Computer Collar fails to beep see the trouble...

Page 9: ...k o With the unit ON press the RANGE UP or the RANGE DOWN buttons to increase or decrease the signal field range The first indicator equals 10 inches of signal field Each additional number represents...

Page 10: ...ar This function is only used with devices set to Shields mode Prior to programming ensure all Computer Collar units are removed from pets and are at least 3 feet from the Shields Gate or any Shields...

Page 11: ...for Different Pets technology please go to the section on multi pet households Once the signal field is established 1 Use the Invisible Fence training flags to mark the desired area Flags should be s...

Page 12: ...If your pet lingers in the signal field or ignores the signal field please contact your Invisible Fence Dealer Your pet s indoor correction level may need an adjustment If your pet is new to Invisible...

Page 13: ...transmitter when the LCD is black will not damage the device Range is too low or too high Check for low battery audible chirp once every 30 seconds and flashing LCD If low battery is indicated plug th...

Page 14: ...geable Lithium Ion Polymer Li ion battery pack with a 3 7 Volt 420 mAh capacity Perchlorate Battery Perchlorate Material special handling may apply See www dtsc ca gov hazardouswaste perchlorate Impor...

Page 15: ...accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a specific installation If interference does...

Page 16: ...___________________________ Dealer Phone_________________________________ System Frequency____________________________ Notes ___________________________________________ _______________________________...