OWNER'S MANUAL

 

Installation and Operating Instructions

 

 

S

AVE THIS OWNER’S MANUAL 

FOR FUTURE REFERENCE 

 

PLEASE READ THIS ENTIRE OWNER’S MANUAL BEFORE YOU INSTALL AND USE YOUR 

NEW INVICTA WOOD STOVE.   

 

 

 

If this room heater is not properly installed, a house fire may result. 

 

 

To reduce the risk of fire, follow the installation instructions. 

 

Failure to follow these instructions can result in property damage, bodily injury, or even death. 

 

Conforms to UL Std. 1482 

 

Certified to ULC Std. S627  

 

 

CONTACT LOCAL AUTHORITIES WITH JURISDICTION (BUILDING DEPARTMENT or FIRE 

 

OFFICIALS),  ABOUT  PERMITS  REQUIRED,  RESTRICTIONS  AND  INSTALLATION 

INSPECTION IN YOUR AREA. 

 

 

 

Summary of Contents for 6110-44

Page 1: ...s not properly installed a house fire may result To reduce the risk of fire follow the installation instructions Failure to follow these instructions can result in property damage bodily injury or eve...

Page 2: ...tly increase the potential for recognizing potential impacts to efficiency Proper draft is important to the efficient operation of your heater Refer to the Normal Operation section of this manual for...

Page 3: ...LS 13 OUTSIDE AIR SUPPLY 14 VENTING COMPONENTS CONFIGURATION REQUIREMENTS 14 OPERATION 19 CONTROLS AND FEATURES 19 Figure 10 Controls Features 19 BUILDING A FIRE 20 BREAKING IN YOUR WOOD STOVE 20 NORM...

Page 4: ...Install the stove in a safe open area away from traffic flow doors and hallways If possible try to install the stove near an existing chimney and chimney connector It is extremely important to instal...

Page 5: ...e door or use the door to force wood in to the stove Never over fire your stove Never put articles of clothing or candles on a hot stove Never connect the stove to a flue used by another appliance Oth...

Page 6: ...these instructions 1 If the fire is too threatening leave the area and call the fire department immediately If not perform the next three steps 2 Close the stovepipe damper if present 3 Keep the stove...

Page 7: ...tions may limit the heating ability of the stove Firebox Capacity 2 32 cubic feet Maximum Log Length Up to 24 61cm Emissions 1 9 g hr Burn Time Up to 6 hrs Note The amount and weight of wood contained...

Page 8: ...Energy Distribution 2015 8 GAYA ARDOISE 6117 44 GAYA FEUILLE 6118 44 ITAYA 6110 44 SYMPHONIA 6115 44 THEIA 6116 44...

Page 9: ...the required clearance from combustible materials that are near the stove Combustibles include walls floor ceiling and chimney chase You must carefully consider the clearances to all of these combusti...

Page 10: ...as follows The minimum floor protection for US installations is 56 1 4in x 33in The minimum floor protection for installations in Canada is 57 1 4in x 43in Figure 3 Hearth Dimensions COMBUSTIBLE SURFA...

Page 11: ...earance to Combustibles Parallel Corner Corner Clearances A B C D E F Single wall Connector 18 46cm 19 48cm 26 66cm 35 89cm 21 53cm 31 5 80cm Double Wall Connector Inc Rear Heat Shield 18 46cm 12 30cm...

Page 12: ...l Pipe Double Wall Pipe Through the wall top flue exit Inc Rear Heat Shield A 9 23cm 7 18 cm B 14 36 cm 12 32cm For double wall pipe clearance to ceiling refer to pipe manufacturer specifications See...

Page 13: ...e in thickness having two 1in air channels separated from combustibles by a minimum of 6in of glass fiber insulation Opening shall be covered and thimble supported with a sheet steel support minimum 2...

Page 14: ...r material Screen the termination using x mesh rodent screen and cover it with a rain wind proof hood flex pipe outside termination mesh and hood supplied by others Contact your dealer for availabilit...

Page 15: ...h or chimney support package also keeps the walls from igniting You must use one when connecting through a wall or ceiling to a prefabricated chimney Only install this stove to a lined masonry chimney...

Page 16: ...installation instructions Use only Type HT 2100 F prefabricated metal chimneys listed per UL 103 or ULC S629 standards Ensure the size of the prefabricated chimney s flue is appropriate for the Invict...

Page 17: ...es where the chimney passes through floors and or ceiling Any insulation material must be at least 2 51 mm from the chimney EXTERIOR CHIMNEY REQUIREMENTS At least 1 25 mm clearance to combustible mate...

Page 18: ...Energy Distribution 2015 18 Figure 9 Typical Chimney Configurations...

Page 19: ...r otherwise operate this wood heater in a manner inconsistent with operating instructions in this manual CHOOSING FIREWOOD Burn only natural firewood known as cordwood in this INVICTA Wood Heater This...

Page 20: ...en wood properly split stack and allow it to air dry for a period of one year Green wood may provide less than 2000 Btu per pound whereas dry wood can provide up to 7000 Btu per pound Stack the firewo...

Page 21: ...Your first fire should make the stove warm but not hot to the touch Visible steam or boiling moisture and hissing indicate the cast iron is too hot At most a few small chunks of wood should be added t...

Page 22: ...fractory panels discolored or warped external parts and damaged finish ANY SIGNS OF OVER FIRING WILL VOID YOUR WARRANTY THE FRONT DOOR MUST REMAIN CLOSED WHEN IN OPERATION REMOVAL AND DISPOSAL OF ASHE...

Page 23: ...e glass gasket groove 9 Place the new glass onto the door 10 Important Center the glass and ensure that the edges of the glass are parallel with the edges of the opening 11 Check glass position again...

Page 24: ...stove performance We recommend you only use INVICTA replacement gaskets when you need to replace your door gasket Contact your dealer for a gasket kit that includes instructions and the gasket for yo...

Page 25: ...or especially well sealed This phenomenon of air starvation within the building is exacerbated if exhaust fans such as clothes dryers bathroom fans or cook stove exhaust fans are in operation within...

Page 26: ...avoid using poor quality or green wood UNCONTROLLED OR SHORT BURN Unsealed or Open Door Close the door tightly or replace the gaskets Air leakage around glass gasket replace gasket Excessive Draft Ch...

Page 27: ...Energy Distribution 2015 27 SAFETY LABEL...

Page 28: ...Energy Distribution 2015 28 WARRANTY...

Page 29: ...Energy Distribution 2015 29 ANNEX PARTS...

Page 30: ...te FB 610606 34 4 Clou 10 AS 610133B 35 1 Registre d arriv e d air secondaire ED RES 1000 36 1 Fa ade FB 610581 37 1 Porte FB 610585 38 1 Axe de porte haut goupille cannel e de 6x40 AV 6306400 39 1 Ax...

Page 31: ...Energy Distribution 2015 31...

Page 32: ...2 Vis t te frais e empreinte hexagonale creuse de 6x35 AV 8636350 35 1 Facade FB 610581 36 1 Axe de porte bas goupille cannel e de 6x40 AV 6306400 37 1 Axe de porte haut goupille cannel e de 6x40 AV 6...

Page 33: ...Energy Distribution 2015 33...

Page 34: ...e FB 610604 34 4 Clou 10 AS 610133B 35 1 Registre d arriv e d air secondaire ED RES 1000 36 1 Fa ade FB 610581 37 1 Porte FB 610585 38 1 Axe de porte haut goupille cannel e de 6x40 AV 6306400 39 1 Axe...

Page 35: ...Energy Distribution 2015 35...

Page 36: ...FB 610608 34 4 Clou 10 AS 610133B 35 1 Registre d arriv e d air secondaire ED RES 1000 36 1 Fa ade FB 610581 37 1 Porte FB 610585 38 1 Axe de porte haut goupille cannel e de 6x40 AV 6306400 39 1 Axe d...

Page 37: ...Energy Distribution 2015 37...

Page 38: ...B 610602 34 4 Clou 10 AS 610129C 35 1 Registre d arriv e d air secondaire ED RES 1000 36 1 Fa ade FB 610581 37 1 Porte FB 610585 38 1 Axe de porte haut goupille cannel e de 6x40 AV 6306400 39 1 Axe de...

Page 39: ...Energy Distribution 2015 39...

Page 40: ...610526U 34 4 Clou 10 AS 610133B 35 1 Registre d arriv e d air secondaire ED RES 1000 36 1 Fa ade FB 610581 37 1 Porte FB 610585 38 1 Axe de porte haut goupille cannel e de 6x40 AV 6306400 39 1 Axe de...

Page 41: ...Energy Distribution 2015 41...

Page 42: ...610641U 34 4 Clou 10 AS 610133B 35 1 Registre d arriv e d air secondaire ED RES 1000 36 1 Fa ade FB 610581 37 1 Porte FB 610585 38 1 Axe de porte haut goupille cannel e de 6x40 AV 6306400 39 1 Axe de...

Page 43: ...ROUP SASU 785 520 180 R C S SEDAN Greffe du Tribunal de Commerce de SEDAN Si ge social INVICTA GROUP SASU ZI LA GRAVETTE 08350 DONCHERY www invicta fr Imported by Import par Energy distribution 1361 D...

Reviews: