3-4
Blinking Red:
In DC Load Control Mode, the controller is in the status of battery low voltage disconnect.
Details of the fault messages could be referred to 3.6.2 Fault Messages.
3.6
LCD Meter Displays
Two optional LCD digital meter displays are available for SunStar controllers: The SS-D
LCD Meter Displays is standard faceplate on the SunStar Controller and the other SS-RD
can be mounted remotely. The remote version is available with either 50 feet or 100 feet
cables. Longer runs may be possible (up to 1000ft/300m) because the communication is a
serial-data type link.
These displays include a two-line, 32-characters LCD and Four status LED indicator
(SS-RD) only.
The LCD provides the following information:
z
Solar PV Array or DC Load press-through current: 0~80 amps DC
z
Battery Voltage: 4 to 80 Volts DC
z
Watts: 0 to 3600 Watts (Volts time Amps)
z
Amp-hours: 0 to 655536Ah; can be reset to 0
z
Totalizing amp-hours: 0 to 65536 Ah; reset to 0 when power is disconnected
z
Control mode and battery charging status
z
Display of BULK and FLOAT voltage setting value
z
Display of Equalization Voltage, Equalization Time and Equalization Interval
z
Display of heatsink temperature and BTS temperature
z
Fault Messages