2-6
M a n u a l/A u to E q u a liz a tio n (7 )
B a tte ry C h a rg in g a lg o rith m (4 ,5 ,6 )
S y s te m V o lta g e (2 ,3 )
(d iv e rs io n c h a rg e c o n tro l)
C o n tro l M o d e (1 )
B a tte ry C h a rg in g
O F F
O N
D IP
O N
8
7
6
5
4
3
2
1
U se r D e fin e C h a rg in g a lg o rith m (8 )
DIP Switch Functions
※
As shown in the diagram, all the positions are in the “OFF” position except switch
number 3 and 7 which are in the “ON” position.
NOTE: The DIP switches should be changed only when there is no power to the
controller. Turn off disconnect switches and remove all power to the
controller before changing a DIP switch. A fault will be indicated if a switch is
changed while the controller is powered.
CAUTION 1: The SunStar is shipped with all the switches in the “OFF” position.
Each switch position must be confirmed during installation. A wrong
setting could cause damage to the battery or other system components.
CAUTION 2: To configure your SunStar for the battery charging and control you
require, follow the DIP switch adjustments described below. Before
changing any switch, make sure the BCD switch is placed at number 0
for the SunStar settings. To change a switch from OFF to ON, slide the
switch up toward the top of the controller. Make sure each switch is
fully in the ON or OFF position.
DIP Switch Number 1-Control Mode: Solar battery charging
Switch 1
Control Mode
ON
Load control mode
OFF
Solar charging mode
(Diversion charge control mode)
For the solar battery charging control mode, leave the DIP switch in the OFF position.